background image

TRT-BA-TTK26E-TC2017-50-006-EN

TTK 26 E

EN

OPERATING MANUAL

DEHUMIDIFIER

Summary of Contents for TTK 26 E

Page 1: ...TRT BA TTK26E TC2017 50 006 EN TTK 26 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...otec com id 41301 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warni...

Page 3: ...en flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Observe the natio...

Page 4: ...ailable from the manufacturer upon request Residual risks Danger Natural refrigerant propane R290 H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away fro...

Page 5: ...panel for operating and controlling the functions Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly the condensation tank...

Page 6: ...ack on Acting contrary might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device proceed as follows Drain the remaining con...

Page 7: ...d When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas s...

Page 8: ...tart up chapter you can switch it on 1 Press the On Off button 19 The operation LED 18 is illuminated Setting the operating mode 1 Repeatedly press the mode button 20 to change the operating mode In c...

Page 9: ...ter a predefined number of hours 1 to max 24 hrs you can programme the timer The timer can be set in all operating modes You can activate the function when the device is switched off Automatic switch...

Page 10: ...paces When positioning the device or a clothes horse please observe the minimum distances specified in the technical data The following humidity values are suitable for drying laundry cupboard dry 46...

Page 11: ...side check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost During automati...

Page 12: ...or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and cl...

Page 13: ...the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Ens...

Page 14: ...he device 6 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly...

Page 15: ...y might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Reconnect the device to the mains If you do not intend to use the device for a considerable time...

Page 16: ...16 EN dehumidifier TTK 26 E Wiring diagram...

Page 17: ...t No Spare Part 1 Water tank 11 Axle 21 Right buckle 2 Front Panel 12 PCB box 22 Anion Generator 3 Filter 13 PCB 23 Display 4 Float 14 Evaporator 24 Handle 5 Water Bracket 15 Back panel 25 Top cover 6...

Page 18: ...dministration For further return options provided by us please refer to our website https de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: