Model #: SMARTINT2200VS

SmartPro 2.2kVA Line Interactive UPS, SNMPWEBCARD option, Tower, USB, Serial, EPO, 230V

 

Highlights

2.2kVA / 2200VA line interactive tower UPS system

230V nominal output during brownouts to 151 and overvoltages to 282V

Front panel status LEDs with load and battery capacity level display

USB, RS232, EPO and optional SNMP/Web interface; 3 switched load banks

C20 inlet; 8 C13 & 1 C19 outlets; 2 C13 to C14 cables included

Description

 Tripp Lite's SMARTINT2200VS intelligent, line interactive tower uninterruptible power supply (UPS) prevents data loss, downtime and equipment
damage due to power outages, voltage fluctuations and transient surges. Large internal batteries offer 19 minutes half load runtime and 7 minutes at
full load. Maintains regulated 230V nominal output without using battery power during brownouts and overvoltages from 151 to 282V. 2200VA power
handling capability offers compatibility with a variety of networking, telecom and other sensitive electronic applications. Includes a total of 9 outlets
with 3 load banks (2 outlets each) that are individually switchable via software interface to reboot select equipment on demand or shed less
significant loads to extend battery runtime for more critical equipment. Supports simultaneous remote monitoring of UPS and site power conditions
via built-in USB and DB9 monitoring ports. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in
accessory slot supports SNMP with optional SNMPWEBCARD adapter. Emergency Power Off (EPO) interface offers option for instantaneous
power-off of UPS and connected equipment in the case of fire or emergency. Multi-function audible alarms and set of 5 front panel LEDs offer
at-a-glance notification of UPS and line power status. Network-grade AC surge suppression protects equipment from damage and performance
problems resulting from transient surges and line noise. Attractive gray color scheme. 

Package Includes

SMARTINT2200VS UPS System

PowerAlert software with USB and DB9 cables

Cable for Emergency Power Off interface

Instruction manual with warranty information

C13 to C14 power cables (3)

Features

SMARTINT2200VS line interactive UPS offers protection from blackouts, brownouts, overvoltages and surges

2200VA / 1600 watt capacity

Internal batteries support a half load of 1100VA for 19 minutes and a full load of 2200VA for 7 minutes

Maintains regulated 230V nominal output during brownouts and overvoltages from 151 to 282V

Includes 9 UPS supported outlets with 3 individually controllable load banks that can be powered off and back on again via software

interface

IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles

PowerAlert UPS monitoring and unattended shutdown software included

Offers simultaneous monitoring by up to 4 directly-connected devices through included USB and DB9 interface ports, or the monitoring by

any number of additional servers over IP with included PowerAlert monitoring software.

Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage,

DC battery voltage and remaining battery capacity

Emergency Power Off (EPO) interface with cable

Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for immediate reboot of

connected devices

Содержание SmartPro SMARTINT2200VS

Страница 1: ...offers option for instantaneous power off of UPS and connected equipment in the case of fire or emergency Multi function audible alarms and set of 5 front panel LEDs offer at a glance notification of UPS and line power status Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise Attractive gray color scheme Package...

Страница 2: ...ltage Frequency compatibility 50 60 Hz Output voltage regulation line mode 19 8 Output voltage regulation Battery mode 5 Built in UPS output receptacles 8 C13 outlet s 1 C19 outlet s Included output power cables Includes 3 C13 to C14 output power cables Built in controllable switched load banks Three switchable two outlet C13 load banks Output circuit breaker 10A x2 each breaker protects 4 C13 out...

Страница 3: ...tween 151 and 176 are boosted by 30 LEDS ALARMS SWITCHES LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Alarms Audible alarm indicates power failure overload and low battery conditions Alarm cancel operation Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status ...

Страница 4: ...le Noise Audible Noise 47dBA At Front Side 1 Meter COMMUNICATIONS Communications interface USB DB9 Serial Contact closure Network monitoring port description Supports detailed monitoring of UPS and site power conditions 2 USB ports 1 DB9 serial and 1 DB9 contact closure port 4 total PowerAlert software Included Communications cable 2 USB and 2 DB9 cables included WatchDog compatibility Supports Wa...

Страница 5: ...tors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 PDU12IEC Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment 1 P004 006 6 ft 18AWG Power cord IEC 320 C14 to IEC 320 C13 1 SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 U022 010 10 ft USB2 0 A B Gold Device Cable A Male to B Male 1 WA...

Отзывы: