manualshive.com logo in svg
background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SMART1500RMXL2UA

SmartPro 1.5kVA 1350W Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 2U
Rack/Tower, LCD, USB, RS232,EPO, 120V

 

Highlights

1.5kVA / 1500VA / 1350W line interactive 2U rack/tower UPS, Sine Wave

120V output, Corrects brownouts and overvoltages from 83V to 145V

0.9 Power Factor, Interactive LCD interface

Extended runtime options up to 1200W

4 post compatible mounting accessories

95% line-mode efficiency, 2 switched load banks

USB, RS232, EPO and slot for SNMPWEBCARD option

120V NEMA 5-15P input, 8 NEMA 5-15R outlets

Description

 Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and
telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects
brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration
excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout
conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and
configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment
without interruption or reboot. 95% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support
communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in
power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of
equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output
load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display
panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode
configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules. 

Package Includes

SMART1500RMXL2UA UPS system

PowerAlert software with USB, Serial & EPO cabling

4 post installation kit

Owner's manual

Features

Tripp Lite SMART1500RMXL2UA line interactive 2U rack/tower UPS with 1500VA / 1.5kVA / 1350W capacity and extended runtime options

Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V

NEMA 5-15P input plug; 8 NEMA 5-15R output receptacles, Two independently switched output load banks

Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages

High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions

Internal batteries offer 14 minutes at 50% load (675W) and 4.9 minutes at 100% load (1350W)

Extended runtime is available with optional BP36V15-2U (limit 1) OR BP36V42-3U (no limit), Output is reduced to 1200 watts maximum with

external battery packs

External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment 

Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7

selectable screens of detailed UPS and site power information

LCD interface also supports a number of advanced user setup and operating preferences

Содержание SmartPro SMART1500RMXL2Ua

Страница 1: ...ws and Mac OS X Network communications ports enable detailed monitoring of equipment load levels self test data and utility power conditions Includes PowerAlert monitoring software and complete cabling Switched output load banks enable scheduled and real time remote reboot and load shedding of select outlets Emergency Power Off EPO interface LCD display panel easily rotates for viewing in rackmoun...

Страница 2: ...1 5 Output Watt Capacity watts 1350 Output kW capacity 1 35 Output power factor 0 9 Output Capacity Details Output derates to 1200 watts in all external battery configurations Nominal Output Voltage s Supported 120V Frequency compatibility 60 Hz Output voltage regulation line mode 14 6 Output voltage regulation Battery mode 5 Built in UPS output receptacles 8 5 15R outlet s Built in controllable s...

Страница 3: ...re reduced by 12 Undervoltage correction Input voltages between 95 and 108 are boosted by 12 Severe undervoltage correction Input voltages between 83 and 94 are boosted by 24 LEDS ALARMS SWITCHES Front panel LCD display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a ...

Страница 4: ...34 2 Rack Height 2U Secondary form factor Tower requires 2 9USTAND UPS Power Module weight lbs 46 5 UPS Power Module weight kg 21 1 UPS Shipping dimensions height x width x depth inches 8 5 x 23 4 x 19 9 UPS Shipping dimensions height x width x depth cm 21 6 x 59 4 x 50 5 Shipping weight lbs 51 3 Shipping weight kg 23 3 Cooling method Fan UPS housing material Steel ENVIRONMENTAL Operating Temperat...

Страница 5: ...ions Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category B EMI ROHS Restriction of Hazardous Substances WARRANTY Product Warranty Period Worldwide 2 year warranty 3 year with registration Note registration is required for 3 year warranty Connected Equipment Insurance U S Canada Puerto Rico 250 000 Ultimate Lifetime Insurance Related Items Optional Products Rel...

Страница 6: ...l time remote monitoring of load level voltage and frequency with options for remote environmental and security monitoring 1 PDUMH15ATNET Switched Metered PDU with ATS Power Distribution Unit with dual input Auto Transfer Switching individual outlet control and remote network interface 1 PDUMV15NET Switched Metered PDU with Remote Monitoring 0U Vertical Rackmount Power Distribution Unit for Networ...

Отзывы: