background image

1

Owner’s Manual

Rackmount 

Network Switch  

with Built-in PDU

Model: NSU-G16 

(Series Number: AG-00C6)

1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support

Copyright © 2016 Tripp Lite. All rights reserved.

PROTECT YOUR INVESTMENT!

Register your product for quicker service  

and ultimate peace of mind. 

You could also win an 

ISOBAR6ULTRA surge protector— 

a $100 value!

www.tripplite.com/warranty

16-05-214-9332E0.indd   1

5/18/2016   10:27:26 AM

Summary of Contents for NSU-G16

Page 1: ...icago IL 60609 USA www tripplite com support Copyright 2016 Tripp Lite All rights reserved PROTECT YOUR INVESTMENT Register your product for quicker service and ultimate peace of mind You could also win an ISOBAR6ULTRA surge protector a 100 value www tripplite com warranty 16 05 214 9332E0 indd 1 5 18 2016 10 27 26 AM ...

Page 2: ...ts Do not use this product near water e g in a wet basement or near a swimming pool PDU Switch Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a fla...

Page 3: ... connexion de la PDU du commutateur Il n est pas recommandé d utiliser cet équipement dans les applications de soutien vital où une panne de cet équipement serait susceptible de causer une panne de l équipement de soutien vital ou d affecter sérieusement sa sécurité ou son efficacité Ne pas utiliser cet équipement dans un milieu où il existe un mélange anesthésique inflammable avec de l air de l o...

Page 4: ...LED illuminates to indicate that the switch is receiving power 3 NEMA 5 15R Outlets This switch includes eight NEMA 5 15R receptacles 4 Circuit Breaker If the current drawn by the equipment connected to the PDU exceeds the Maximum Load Rating the 12A thermal circuit breaker will trip to prevent possible damage and its plunger will pop up If this happens disconnect excess equipment and allow the br...

Page 5: ...the rackmount screws to hold the unit in the rack before installation 2 Connect the switch to a properly grounded outlet The POWER LED will illuminate when the switch turns on 3 Connect the network cables to the network switch 4 Connect equipment to the PDU outlets Make sure the load connected does not exceed the PDU s circuit breaker rating 1 3 4 2 A C C A B B D D 16 05 214 9332E0 indd 5 5 18 201...

Page 6: ...ompliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marketing name or model number ...

Page 7: ...7 Notes 16 05 214 9332E0 indd 7 5 18 2016 10 27 32 AM ...

Page 8: ...8 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 16 05 214 93 32E0_revD 16 05 214 9332E0 indd 8 5 18 2016 10 27 32 AM ...

Reviews: