INSTALLATION INSTRUCTIONS for MODELS  

SG10-RG (Incandescent) and SG10-RG-LED

IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS

[email protected] | t: 1-773-384-7765 | f: 1-773-384-5115 | www.triliteinc.com | Designers and manufacturers of specialty electrical products. Since 1922.

953063 | REV B

A1612R 

   Red signal assembly, 12 VDC

A1612G 

   Green signal assembly, 12 VDC

A1624RH 

   Red signal assembly, 24 VAC/VDC

A1624GH 

   Green signal assembly, 24 VAC/VDC

A16115R 

   Red signal assembly, 120 VAC

A16115G 

   Green signal assembly, 120 VAC

LIMITED WARRANTY

This Tri Lite product may incorporate an LED bulb, warranted to be free from defects in materials and/or workmanship for (3) three years from the date of delivery to 
Purchaser. The Limited Warranty does not apply to severe applications. 

All other components within this unit are under warranty for (1) year. If any component parts do not conform exactly to the specifications and physical dimensions referred 

to above, and the Purchaser, at its expense, returns the product or component parts to the Seller together with a report of defects, the Seller shall review the inspection 
report and inspect the items and shall authorize, at its option, either the repair or replacement of any non-conforming products or component parts. Upon expiration of 
the warranty period, all liability of the Seller shall be terminated.

Seller shall not be liable for any injury, loss or damage, direct or consequential arising out of the use or the ability to use the product. This warranty gives specific legal 

rights. You may have other rights, which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so that the 
above limitation of exclusion may not apply to you.

CAUTION! 

 The individual user should determine prior to use whether this device is suitable, adequate,  

or safe for the use intended. Since individual applications are subject to great variation, the manufacturer 

makes no representation or warranty as to the fit or suitability of these devices for any specific application.

CAUTION! 

 Ensure that the power supply matches the voltage rating of the light.

CAUTION!

 Units with incandescent lamps require a flashing power supply or integrated flasher device to 

avoid heat damage to the lens. LED units can operate safely when not flashing.

CAUTION! 

12 volt units with LED lamps require careful control of the DC input voltages if generated from 

AC power sources. Ensure that voltage does not exceed 110% of rated voltage.

REPLACEMENT PARTS LIST

Part# 

   Descriptions

SG10 CONFIGURATIONS

SG10-12RG   

12v 

       2.17 

Incandescent

SG10-12RG-LED       12 VDC        0.30 

LED

SG10-24RG      

24v              1.10 

Incandescent

SG10-24RG-LED       24v 

       0.11 

LED

SG10-115RG             120v         0.21 

Incandescent

SG10-115RG-LED     120v         0.03 

LED

Part# 

 

Voltage        Amps 

Bulb Type

These models are intended for use with external peripheral controls and circuitry provided by the user.

1.  Choose a location within convenient distance to a suitable power source. The power connection can be 

through the underside of the housing or through the back plate. Use the ½” EMT fitting provided.

2.  Using the housing as a template, mark and drill four (4) corner holes in an appropriate mounting location.  

If mounting to brick or masonry, size the holes to accept ¼” diameter lag-type fasteners and anchors.

3.  Use the back plate gasket provided when mounting unit to the wall.
4.  Connect the control/supply wires to an appropriate external switching device.  

See wiring diagram for reference.

Summary of Contents for SG10-12RG

Page 1: ...mitation of incidental or consequential damages so that the above limitation of exclusion may not apply to you CAUTION The individual user should determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no representation or warranty as to the fit or suitability of these devices f...

Page 2: ...fabricant ne fait aucune représentation et n offre aucune garantie quant à la pertinence et au caractère approprié de ces dispositifs pour une application particulière MISE EN GARDE S assurer que la source d alimentation correspond à la tension nominale de la lumière MISE EN GARDE Les unités équipées de lampes incandescentes nécessitent une source d alimentation clignotante ou un dispositif cligno...

Page 3: ...73 384 7765 f 1 773 384 5115 www triliteinc com Designers and manufacturers of specialty electrical products Since 1922 953063 REV B RED SG10 12RG VDC UNIT SG10 24RG VAC VDC UNIT GREEN X2 Internal Connection Do Not Modify External Connection Capacitor Incandescent Only X2 GROUND CHASSIS This wire used on Incandescent 120 VAC units only LABELED GREEN LABELED GREEN ...

Page 4: ...384 5115 www triliteinc com Designers and manufacturers of specialty electrical products Since 1922 953063 REV B ROUGE SG10 12RG VCC UNITÉS SG10 24RG VCA VCC UNITÉS VERT X2 X2 ÉTIQUETÉ VERT Connexion interne Ne pas modifier Connexion externe Condensateur Incandescente uniquement ÉTIQUETÉ VERT Ce fil est utilisé uniquement sur les unités incandescentes de 120 VCA MASSE DU CHÂSSIS ROUGE VERT ...

Reviews: