background image

Order code: BOTE73

HS2 Hybrid PowerCON 

DMX Distribution Splitter

User Manual

Summary of Contents for HS2 Hybrid Distribution Splitter

Page 1: ...Order code BOTE73 HS2 Hybrid PowerCON DMX Distribution Splitter User Manual ...

Page 2: ...the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is 240V AC 50Hz Make sure that the power cable is never crimped or damaged Check the equipment...

Page 3: ...R output per channel Each DMX output features an independent driver 100 electrical isolation between all inputs outputs 2 way PowerCON power distributor with one input and two outputs M10 rigging point Safety bond point Rugged steel chassis HS2 Hybrid PowerCON DMX Distribution Splitter Specifications Power supply 240V 50Hz Fuse F1A 250V Dimensions 61 x 160 x 175mm Weight 1 1kg Order code BOTE73 HS...

Page 4: ...0V 07 Earth point 08 Safety eye 09 M10 rigging point In the box 1 x HS2 distribution splitter 1 x power cable 1 x user manual Technical specifications HS2 Hybrid PowerCON DMX Distribution Splitter DMX OUTPUT 1 DMX OUTPUT DC POWER OUTPUT 1 240V 50Hz POWER OUTPUT 2 240V 50Hz MAX 20A TOTAL LOAD POWER INPUT 240V 50Hz DMX INPUT FUSE F1A 250V DMX OUTPUT 2 DMX OUTPUT DC 04 06 10 02 07 01 03 09 05 ...

Page 5: ...l cable may be connected with up to 32 fixtures per signal line and up to 100m cable length Connect the HS2 to a suitable 240VAC 50Hz mains supply via the PowerCON mains inlet LED indicators The HS2 is fitted with signal and DC indicators Under normal conditions with DMX signal passing through the unit both LEDs will be illuminated The DMX LED indicates the presence of a DMX signal The DC LED indi...

Page 6: ...at travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission wh...

Page 7: ...r own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour Special note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Using a cable terminator will decreas...

Page 8: ...revent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for enviro...