background image

SPL Series

Digital Bench Scale

Operation Manual

Revision 1.2

December 17, 1998

Summary of Contents for SPL Series

Page 1: ...SPL Series Digital Bench Scale Operation Manual Revision 1 2 December 17 1998 ...

Page 2: ... 1998 Transcell Technology Inc Contents subject to change without notice Transcell Technology Inc 975 Deerfield Parkway Buffalo Grove IL 60089 Tel 847 419 9180 Fax 847 419 1515 ...

Page 3: ... default settings USE WITH CAUTION Press the ZERO key to execute CHANGES TO USER MENU CHART SECTION A2 Data Bits Parity 8n 7O 7E 7n A4 Serial Data Format 0 1 2 3 4 CHANGES TO USER MENU DESCRIPTIONS SECTION A2 Data Bits and Parity Selects the number of data bits and parity of serial transmission 8n 8 data bits with no parity bit and one stop bit 7O 7 data bits with odd parity bit and one stop bit 7...

Page 4: ...REV 8 93 Table of Contents Introduction 1 Installation and Wiring 1 Keyboard Functions 1 Configuration 2 User Menu Descriptions 2 Calibration 3 Specifications 4 Warranty and Service Information 5 ...

Page 5: ...ry Simply con nect the indicator to the scale platform plug in the AC adapter and turn the unit on If the swivel indicator option was ordered the stainless steel post may be mounted to the bottom of the base with the hardware provided Alternately it may be mounted to a table or bench In general please allow a 20 minute warm up period before using the scale If interfacing to a PC simply connect the...

Page 6: ...2 PRINT Sends Print data to printer if scale is stable and not in overload Not active when Continuous option is selected in User Menu ...

Page 7: ...on þ When the display shows A1 the unit is in USER MENU mode and you can release the lb kg key Shown at right are the directional and SET key assign ments SPL MODEL SET kg NET GROSS USER MENU CHART A1 Baud Rate 1200 2400 4800 9600 A2 Data Bits Parity 8n 7O 7E A3 Transmission Mode C d A4 Serial Data Format A5 Disable lb kg Key 1 0 0 1 2 3 To place the unit back into the NORMAL OPERATING mode turn o...

Page 8: ...smission Selects when data will be sent out of the serial port to a printer or computer C Continuous mode send data continuously d Demand mode send data when a PRINT command is issued from the printer computer or indicator C d ...

Page 9: ...O to zero the value then press the NET GROSS key to save the zero point value þ The display will momentarily prompt C 1 for the span calibration followed by 0 00 with one digit flashing Place the test weight on the platform þ Use the four directional keys to adjust the displayed value to the actual test weight value in pounds Increase the flashing digit by pressing the lb kg key Decrease the flash...

Page 10: ...URE RANGE 32 F to 104 F 0 C to 40 C OPTIONAL SWIVEL POST 12 30mm Tall Stainless Steel Construction POWER SOURCE AC Adapter 12VDC 500mA included WEIGHT Net Weight 19 4 lb 8 8 kg Shipping Weight 21 6 lb 9 8 kg PHYSICAL DIMENSIONS SPL MODEL ZERO kg lb GROSS NET TARE kg NET GROSS PRINT 6 8 in 173mm 3 2in 81mm 1 4in 35mm REMOTE INDICATOR 13 2in 336 00mm 10 2in 258 00mm 3 8in 97 50mm ON OFF SWITCH DC PO...

Page 11: ...used by accident misuse neglect alteration improper installation improper or un authorized repair or improper testing and 4 Such goods have not been modified altered or changed by any person other than the Seller or its duly authorized repair agents 5 Transcell Technology Inc will have a reasonable time to repair or replace such goods THESE WARRANTIES EXCLUDE ALL OTHER WARRANTIES EXPRESS OR IMPLIE...

Reviews: