background image

Installation Instructions

P710U--21PHP

Universal Application

Programmable Thermostat

Designed and Assembled

in the USA.

A13408

Universal Application Programmable Thermostat

NOTE

: Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

2

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2 — Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

2

. . . . . . . . . . . . . . . . .

Step 4 — Thermostat Operation

3

. . . . . . . . . . . . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

3

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified

installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local

building codes and the current editions of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in the instructions or

manuals, be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies a hazard

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

INTRODUCTION

The TOTALINE Universal Application programmable thermostat
can be configured for both AC and HP applications. Both modes

are dual--powered, operating from either 24VAC or two alkaline
AA batteries. Configuration and program schedules are stored in

non--volatile memory, preserving this information during power

loss and battery removal. Features include simplified 5/2
programming, large backlit display, and modern styling.
When AC application is selected, one stage of heating and one
stage of cooling are provided.
When HP application is selected, two stages of heating and one

stage of cooling are provided.

INSTALLATION CONSIDERATIONS

The P710U--21PHP, whether configured for A/C or HP

application, may be wired with or without connecting a common
wire between the indoor equipment and the thermostat. However, it

is recommended to use a common wire whenever possible.
Without a common wire, batteries must be installed. However,

battery power will be supplemented by “power stealing.”
This means the thermostat will steal a small amount of power from
the equipment to which it is connected. This will also keep it

powered while changing the batteries.

NOTE

:

Not all HVAC equipment is compatible with

power--stealing type thermostats. Consult the system equipment
Installation Instructions before applying this thermostat in a power
stealing manner.
If both batteries and 24VAC operation are used (batteries installed
and the common wire connected), indefinite clock operation is

provided. The battery will be used only during AC power loss,
preserving battery life.

Summary of Contents for P710U-21PHP

Page 1: ...bol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation IN...

Page 2: ...t casing may also af fect thermostat operation by interfering with airflow across the temperature sensor 9 Locate jumper marked J2 on circuit board If common C wire has been connected put J2 in the 24VAC position If no common wire leave J2 in the default BATT position 10 Set the thermostat front housing into the 2 notches on the bottom of the mounting plate 11 Rotate the front housing forward and ...

Page 3: ... come on for 10 seconds after any button press Without AC power and when the battery is low the backlight will remain off with button presses Battery Indicator A battery indication icon on the display shows nothing half or low no battery condition If the battery is full or operation is from AC power no icon appears Under battery operation if the battery is half full a half full battery icon appear...

Page 4: ...uttons simulta neously to defeat timers Cooling system should begin to operate immediately Table 1 shows the thermostat outputs for each available stage of heating or cooling It may be useful in checkout or troubleshooting Table 1 Outputs EQUIPMENT CONFIGURATION OP TION 1 COOL STAGE 1 HEAT STAGE 1 HEAT STAGE 2 EM HEAT AC PC Y G W HP PH RVS C Y G O B Y G Y G W W HP PH RVS H Y G Y G O B Y G W O B W ...

Page 5: ...by the FAN ON icon and auto fan operation 3 To Read the Room Temperature The large display reads room temperature until a button is pressed 4 To Adjust the Setpoint In normal operation the large display shows room temper ature At the first press of the UP or DOWN button the large display shows the current setpoint and the SET TEMP icon is turned on Further presses of the UP or DOWN but ton adjust ...

Page 6: ...ettings to the programmed comfort schedule Pressing HOLD END will not alter your programmed comfort schedule Method 2 Temporary Override At the first press of the UP or DOWN button the current temperature setting will appear on the display Pressing the UP or DOWN button again will temporarily change the setpoint as needed At the next programmed time the programmed comfort schedule will resume AUXI...

Page 7: ...E PERIOD TIME COOL HEAT MoTuWe ThFr TIME COOL HEAT SaSu TIME COOL HEAT MORNING 6 00 A M 78_F 26_C 68_F 20_C 1 2 3 13 14 15 DAY 8 00 A M 85_F 29_C 60_F 16_C 4 5 6 16 17 18 EVE 5 00 P M 78_F 26_C 68_F 20_C 7 8 9 19 20 21 NIGHT 10 00 P M 82_F 28_C 60_F 16_C 10 11 12 22 23 24 ...

Page 8: ...t parts SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER SERVI...