background image

 
 
 
 
 

 
 
 
 
 

T1000 SERIES

 

UPSMON PRO USER GUIDE 

120V   1-3kVA 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Document: 96449 -001 
March 2020 

 

 

Summary of Contents for UPSMON PRO T1000 Series

Page 1: ...T1000 SERIES UPSMON PRO USER GUIDE 120V 1 3kVA Document 96449 001 March 2020 ...

Page 2: ...es low battery disconnect etc Set up UPS features ex silence battery test no load shutdown outlets control etc Share UPS status to the other UPSMON PRO Multi Windows Linux Start web portal for remote monitoring NOTE We strongly recommend you log in as administrator to install UPSMON PRO Opening UPSMON PRO Monitoring Software To start the software Double click the UPSMON PRO icon in the system tray...

Page 3: ...UPSMON PRO User Guide 96449 001 3 UPSMON PRO buttons and indicators Button Current Status ...

Page 4: ...UPS Load The percentage of the UPS load Battery Remaining Time Estimated battery remaining minutes for discharging Indicator Function Power Source Utility Normal Power and the battery is charging Power Source Utility Power Failed and the battery is discharging Battery Capacity 100 full and healthy Battery Capacity 75 full Battery Capacity 50 remains Battery Capacity 25 and battery capacity is almo...

Page 5: ... NOTE In Windows 2003 and XP You also have to enable the hibernate in Power Options Properties to support OS Hibernate 3 b Power Failure Windows Shutdown Delay after this period of time the OS starts to shutdown 1 4 c Battery limited capacity shutdown once the battery is declining to this level the OS starts to shutdown 1 5 d Low battery shutdown if the status of the battery is declining to low le...

Page 6: ...is amount of time to run execute then UPSMON PRO will start OS shutdown 7 f UPS shutdown Delay this duration is gives time for PC shutdown as shown in the below figure 2 NOTE The total time span between power failure PC shutdown and UPS OFF Shutdown depends on UPS load and the battery capacity etc ...

Page 7: ...isplays all UPS events which have taken place Button Historical Event Checking Data Graph 1 Button Record Viewer 2 Records and actively shows UPS information I P Voltage I P Frequency O P Voltage and Battery 3 Calendar view for checking Historical Events a ...

Page 8: ...on 1 Button Notification 2 Enable this function 3 Enter your SMTP Mail server s information ex SMTP Server User name Port Authentication Sender s mail Receiver s mail 4 With Mail Test button it can check your mail configuration and connection NOTE This feature requires your e mail account support SMTP Server ...

Page 9: ...For Specified Time Period Min exhaust the battery capacity for this period of time Test Until Battery Low exhaust the battery capacity to battery low condition Cancel Test Stop battery testing 2 Green Mode Green Mode ON Once the blackout occurs and load is low the UPS automatically turns off Green Mode OFF UPS will sustain power to its limit 3 Silence Click the button Enable Power Failure UPS Soun...

Page 10: ...et shutdown sequence for blackout condition NOTE This feature requires the specific UPS to support Multi OS Connect The UPSMON PRO can function as both Host or Client 1 UPSMON PRO Host The PC who physically connects to UPS via RS232 USB functions as Host Host can share the UPS status to the other Clients Ex 10 192 136 231 Host s PC IP address ...

Page 11: ...SMON PRO Client Via Internet Intranet and UPSMON PRO Host All other PCs connect to UPSMON PRO Host UPSMON PRO Clients can do any behavior like Host Ex Shutdown Client PC Choose UPSMON PRO with Host IP address Host Client Client Client Client ...

Page 12: ...ternet Intranet and UPSMON PRO Host Other PCs connect to UPSMON PRO Host Execute the UPSMON PRO for Linux application upsmon Choose UPSMON PRO with Host IP address UPSMON Start Monitor Connection is successful You can check the UPS status with X Windows by executing display application display ...

Page 13: ...UPSMON PRO User Guide 96449 001 13 NOTE Mutually network connection is necessary for this function ...

Page 14: ...Occurrences Once Daily Weekly Monthly 3 Event UPS shutdown UPS start Battery Test 4 If you set up the UPS shutdown all the other UPSMON PRO Clients will execute OS shutdown earlier 30 seconds than UPSMON Host NOTE The time of UPS shutdown must be earlier than UPS start 5 You can check the last UPS schedule for the current status ...

Page 15: ... 1 2016 8 30 19 59 30 Pop up 30 seconds count down message 2016 8 30 19 59 30 All the other UPSMON PRO Clients start to shutdown OS 2 2016 8 30 20 00 00 UPSMON PRO Host start to shutdown OS 3 After f UPS shutdown Delay minutes UPS stops supplying power 4 2016 8 31 06 00 00 UPS starts to supply power ...

Page 16: ...browser 1 Button Connect 2 a Enable Web Server UPSMON Function 3 IP Address Make sure this Windows has an IP address ex 10 192 136 231 4 b Port 8000 default 5 c Default User Name UPSMON 6 d Default Password UPSMON NOTE This feature requires your Windows have a connectable IP address ...

Page 17: ...UPSMON PRO User Guide 96449 001 17 ...

Page 18: ...SOCIAL INFRASTRUCTURE SYSTEMS GROUP POWER ELECTRONICS DIVISION 13131 West Little York Rd Houston TX 77041 Tel 855 803 7087 Fax 713 896 5212 US 800 231 1412 Canada 800 872 2192 Mexico 01 800 527 1204 www toshibaups com Printed in the USA ...

Reviews: