background image

TOSHIBA INTERNATIONAL CORPORATION

INDEX

 

MDS-O-0001 

Industrial Division / Houston Motor Plant

 

SHEET NO.

 

1 of 3

 

 

ISSUED

 

01/24/96

 

Motor Operation Procedure

SUPERSEDES

 

NEW

 

 

REVISION

 

0

 

REFERENCE USE ONLY WHEN ISSUED BY MOTOR MKTG. 

WRITTEN BY

 

I. MARQUEZ 

 

APPROVED BY

 

J. Bugbee 

Motor Lubrication

 

 

Dist: Mktg. 
 QC 

 
1. SCOPE 

 

To give recommended guidelines for electric motor relubrication. 

 

2. START 

UP

 

 

Toshiba motors are properly greased at the time of manufacture.  It is recommended that 
if a motor has been stored for a period of six months or more, it should be lubricated prior 
to starting (See Fig. 1) using a standard hand held grease gun. 

 

 

Fig.  1 

FRAME SIZE 

QUANTITY of PUMPS 

 

 

 

143 ~ 256 

 

284 ~ 405 

 

444 and Larger 

2 to 3 strokes 

 

4 to 5 strokes 

 

6 to 10 strokes 

 

 

 
 

 

It should be noted that grease leakage around the shaft hole could indicated over-
packing.  Excess grease should be purged out by operating the motor temporarily with 
the relief open. 

 
 

Lubrication of electric motors should be done as a part of a planned maintenance 
program. 

 
 

Before greasing, be sure fittings are clean and free from dirt.  Always relubricate using 
grease that is fresh and free from contamination. 

 
 

Toshiba motors may be equipped with an automatic grease relief fitting, grease plug or 
grease cover plate for the outlet. 

 
 

It should be noted that it may be necessary to remove an automatic type fitting due to 
hardening of grease.  Motors utilizing a grease plate may require the scraping out of old 
grease a minimum of once every two years. 

 

3. STANDARD 

SERVICE

 

 

1. 

Select the proper service condition from Fig. 2. 

 
2. 

Select the frequency and volume from Fig. 3. 

 
3. 

Before greasing be sure fittings are clean and free from dirt. 

 
 