background image

© Titan Tool Inc.  All rights reserved. 

1

Instruction Sheet

2-Finger w/tip 

0296236

4-Finger w/tip 

0296235

2-Finger w/tip 

0296306

2-Finger no tip 

0296307

4-Finger w/tip 

0296321

4-Finger, no tip 

0296322

G-10

High Capacity Spray Gun

Safety Precautions

IMPORTANT SAFETY INSTRUCTIONS

A.  SAVE THESE INSTRUCTIONS – To reduce the risks of fire 

or explosion, electrical shock, and the injury to persons, read 

and understand all instructions included in this manual.  Be 

familiar with the controls and the proper usage of the 

equipment.

B.  WARNING – To reduce the risk of fire or explosion:

  1.  Do not spray flammable or combustible materials near an open flame, 

pilot lights or sources of ignition such as hot objects, cigarettes, 

motors, electrical equipment and electrical appliances.  Avoid creating 

sparks from connecting and disconnecting power cords.

  2.  Use extreme caution when using materials with a flashpoint below 

70ºF (21ºC). Flashpoint is the temperature that a fluid can produce 

enough vapors to ignite.

  3.  Paint or solvent flowing through the equipment is able to result in 

static electricity.  Static electricity creates a risk of fire or explosion in 

the presence of paint or solvent fumes.  All parts of the spray system, 

including the pump, hose assembly, spray gun and objects in and 

around the spray area shall be properly grounded to protect against 

static discharge and sparks. Use only conductive or grounded high-

pressure airless paint sprayer hoses specified by the manufacturer.

  4.  Verify that all containers and collection systems are grounded to 

prevent static discharge.

  5.  Connect to a grounded outlet and use grounded extension cords 

(electric models only).  Do not use a 3 to 2 adapter.

  6.  Do not use a paint or solvent containing halogenated hydrocarbons.  

Such as chlorine, bleach mildewcide, methylene chloride and 

trichloroethane.  They are not compatible with aluminum.  Contact the 

coating supplier about compatibility of material with aluminum.

  7.  Keep spray area well ventilated.  Keep a good supply of fresh air 

moving through the area to keep the air within the spray area free 

from accumulation of flammable vapors. Keep pump assembly in well 

ventilated area.  Do not spray pump assembly.

  8.  Do not smoke in the spray area.

  9.  Do not operate light switches, engines, or similar spark producing 

products in the spray area.

  10.  Keep area clean and free of paint or solvent containers, rags, and 

other flammable materials.

  11.  Know the contents of the paint and solvents being sprayed.  Read 

all Material Safety Data Sheets (MSDS) and container labels 

provided with the paints and solvents.  Follow the paint and solvent 

manufacture’s safety instructions.

  12.  Place pump at least 25 feet (7.62 meters) from the spray object in a 

well ventilated area (add more hose if necessary).  Flammable vapors 

are often heavier than air. Floor area must be extremely well ventilated.  

The pump contains arcing parts that emit sparks and can ignite vapors.

  13.  Plastic can cause static sparks.  Never hang plastic to enclose spray 

area.  Do not use plastic drop cloths when spraying flammable 

material.

  14.  Fire extinguisher equipment shall be present and working.

C.  WARNING – To reduce the risk of skin injection:

HAzARd:  

Injection Injury - A high pressure fluid stream produced by this 

equipment can pierce the skin and underlying tissues, leading to a 

serious injury and possible amputation.  See a physician immediately.  

dO NOT TREAT AN INjECTION INjURY AS A SIMPlE CUT.

  1.  Do not aim the gun at, or spray any person or animal.

  2.  Keep hands and other body parts away from the discharge. For 

example, do not try to stop leaks with any part of the body.

  3.  Always use the nozzle tip guard.  Do not spray without the nozzle tip 

guard in place.

  4.  Only use a nozzle tip specified by the manufacturer.

  5.  Use caution when cleaning and changing nozzle tips.  In the case 

where the nozzle tip clogs while spraying,  

 

  ALWAYS lock gun trigger, shut pump off, and release all pressure 

before servicing, cleaning tip or guard, or changing tip.  Pressure will 

not be released by turning off the motor.  The PRIME/SPRAY valve 

handle must be turned to PRIME to relieve the pressure.  Refer to 

PRESSURE RELIEF PROCEDURE described in the pump manual.

  6.  Do not leave the unit energized or under pressure while unattended. 

When the unit is not in use, turn off the unit and relieve the pressure in 

accordance with the manufacturer’s instructions.

  7.  High-pressure spray is able to inject toxins into the body and cause 

serious bodily injury.  In the event that injection occurs, seek medical 

attention immediately.

  8.  Check hoses and parts for signs of damage, a leak can inject material 

into the skin. Inspect hose before each use.  Replace any damaged 

hoses or parts.

  9.  This system is capable of producing 3600 PSI / 25 MPa.  Only 

use replacement parts or accessories that are specified by the 

manufacturer and that are rated a minimum of 3600 PSI.  This includes 

spray tips, nozzle guards, guns, extensions, fittings, and hose.

  10.  Always engage the trigger lock when not spraying.  Verify the trigger 

lock is functioning properly.

  11.  Verify that all connections are secure before operating the unit.

  12.  Know how to stop the unit and bleed pressure quickly. Be thoroughly 

familiar with the controls.  Pressure will not be released by turning off 

the motor.  The PRIME/SPRAY valve handle must be turned to PRIME 

to relieve the pressure.  Refer to PRESSURE RELIEF PROCEDURE 

described in the pump manual.

  13.  Always remove the spray tip before flushing or cleaning the system.

d.  WARNING – To reduce the risk of injury:

  1.  Always wear appropriate gloves, eye protection, clothing and a 

respirator or mask when painting.  Hazardous vapors – Paints, 

solvents, insecticides, and other materials can be harmful if inhaled or 

come in contact with body.  Vapors can cause severe nausea, fainting 

or poisoning.

  2.  Do not operate or spray near children.  Keep children away from 

equipment at all times.

  3.  Do not overreach or stand on an unstable support.  Keep effective 

footing and balance at all times.

  4.  Stay alert and watch what you are doing.

  5.  Do not operate the unit when fatigued or under the influence of drugs 

or alcohol.

  6.  Do not kink or over-bend the hose. Airless hose can develop leaks 

from wear, kinking and abuse.  A leak can inject material into the skin.  

  7.  Do not expose the hose to temperatures or pressures in excess of 

those specified by manufacturer.

  8.  Do not use the hose as a strength member to pull or lift the equipment.

  9.  Use lowest possible pressure to flush equipment.

  10.  Follow all appropriate local, state and national codes governing 

ventilation, fire prevention and operation.

  11.  The United States Government Safety Standards have been adopted 

under the Occupational Safety and Health Act (OSHA).  These 

standards, particularly part 1910 of the General Standards and part 

1926 of the Construction Standards should be consulted.

  12.  Before each use, check all hoses for cuts, leaks, abrasion or bulging 

of cover.  Check for damage or movement of couplings.  Immediately 

replace hose if any of those conditions exist. Never repair a paint hose.  

Replace with a conductive high-pressure hose.

  13.  Do not spray outdoors on windy days.

  14.  Always unplug cord from outlet before working on equipment.

0711 •

 Form No. 0286928C

Summary of Contents for G-10

Page 1: ...other body parts away from the discharge For example do not try to stop leaks with any part of the body 3 Always use the nozzle tip guard Do not spray without the nozzle tip guard in place 4 Only use a nozzle tip specified by the manufacturer 5 Use caution when cleaning and changing nozzle tips In the case where the nozzle tip clogs while spraying ALWAYS lock gun trigger shut pump off and release ...

Page 2: ...o clear a clogged tip a Rotate the tip 180º so that the arrow on the tip handle is pointing opposite the spray direction b Trigger the gun once so that the pressure can blow the clog out important Never pull the trigger more than once at time with the tip in the reverse position c Continue this procedure until the tip is clear of the clog Changing a Tip Tips can be removed and replaced easily with...

Page 3: ... rear housing is flush against the gun head 2 Unscrew the lock nut 3 4 of a turn NOTE To check the adjustment of the seal assembly 1 Move the gun trigger lock to the locked position 2 Pull the trigger With the trigger lock engaged there should be 1 32 of movement between the lock nut and the rear housing while pulling the trigger Replacing Removing the Filter 1 Pull the bottom of the trigger guard...

Page 4: ...e End User transportation prepaid THERE IS NO OTHER EXPRESS WARRANTY TITAN HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD SPECIFIED IN THE EXPRESS WARRANTY IN NO CASE SHALL TITAN LI...

Reviews: