background image

www.mythomson.com

V1

EN

SESAME 250 - CONNECT

Pivoting arm motor drive kit

For 2-panel swing gates

 

510062

0,35 € / min

0 892 701 369

Google Play

Free available on

Available on the

Google Play

Free available on

Available on the

24V

Solar

OPTION

2,50m / 250kg

per panel

emergency

battery

Solar Power

24V

Solar

OPTION

2,50m / 250kg

per panel

emergency

battery

Solar Power

24V

Solar

OPTION

2,50m / 250kg

per panel

emergency

battery

Solar Power

24V

Solar

OPTION

2,50m / 250kg

per panel

emergency

battery

Solar Power

V6

24V

Solaire

OPTION

Batterie

de secours

OPTION

2,50m / 250kg

par battant

Summary of Contents for 510062

Page 1: ...701 369 Google Play Free available on Available on the 24V Solar OPTION 250kg anel emergency battery Solar Power 24V Solar OPTION emergency battery Solar Power 24V emergency battery Solar Power 24V So...

Page 2: ...G 07 B PRODUCT DESCRIPTION 08 1 KIT CONTENTS 08 2 EQUIPMENT REQUIRED NOT INCLUDED 09 C INSTALLATION 10 1 HAZARD ANALYSIS 10 1 1 Regulations 10 1 2 Specifications of the gate to motorise 10 1 3 Safety...

Page 3: ...property 22 4 INSTALLING THE FLASHING LIGHT 27 5 INSTALLING THE SET OF PHOTOCELLS 28 5 1 Opening outwards 28 5 2 Opening inwards 29 5 3 2nd set of photocells optional 30 6 CONNECTIONS 32 6 1 The mains...

Page 4: ...rating mode 43 2 4 Time delay 43 2 5 Motor force 44 2 6 Speed 44 2 7 Self learning 44 2 8 Programming remote controls 46 3 ADVANCED SETTINGS 47 3 1 Access to advanced settings MENUS 2 and 3 48 3 2 Adv...

Page 5: ...of events and error codes 56 2 2 Manual control 57 2 3 Total reset 58 2 4 Replacing the remote control battery 58 2 5 Replacing the power fuse 59 G TECHNICAL AND LEGAL INFORMATION 60 1 COMPATIBLE ACC...

Page 6: ...ed in the use of the device may set the gate into motion Before setting the gate into motion ensure that there is no person in the area in which the gate moves Avoid any natural obstacles branch stone...

Page 7: ...abrasive or corrosive substances to clean the product Do not clean the product with a pressure washer Use a lightly damp soft cloth Do not use aerosol sprays on the product because they could damage i...

Page 8: ...ry motor 3 Remote control 4 Flashing light and screws 5 Rear arm 6 Front arm 7 Post mounting bracket 8 Gate mounting bracket 9 M12 L40 screw 10 M8 L25 screw 11 M10 L90 screw 20 x 1 20 x 6 20 x 6 20 x...

Page 9: ...ing light onto the post Motor Flashing light 10m cable 4 x 6 10 8m cable 2 x 1 5mm2 3m cable 2 x 0 5mm2 Attachment of the brackets on the gate Choose a screw nut system that is suitable for the thickn...

Page 10: ...to protect the gate s automatic closing The flashing light is an essential safety component The photocell type safety devices and their correct operation must be checked every six months 1 2 Specific...

Page 11: ...are as follows 2 1 Subpanels Following installation there may be a shear zone between the panel and the corner of the post In this case it is recommended to remove this zone leaving a minimum working...

Page 12: ...rised gate is installed there may be confinement areas between the panels in open position and the fixed parts close to them To remove these areas it is mandatory to leave a safe distance of 500mm bet...

Page 13: ...the indications provided in the General warnings Before starting installation ensure that Hazards can be minimised by following the recommendations under the Chapter Hazard analysis The desired use h...

Page 14: ...han 30m long Cable 3 x 1 5mm2 less than 30m long Unlimited 2 Flashing light Cable 2 x 0 5mm2 15m 3 Secondary motor 2 x 1 5mm cable 10m 4 Reception photocell RX 4 x 6 10 cable 10m 5 Transmission photoc...

Page 15: ...ferent for each panel but must never be less than 40 For opening up to Distance D in mm 90 50 D 200 98 50 D 150 105 50 D 100 115 50 D 50 125 50 D 0 135 50 central stop Inner side of the property view...

Page 16: ...the parts together the different pivoting parts must be able to turn freely 3 3 Installing the motors for opening towards the inside of the property Place the mounting brackets against the posts 14mm...

Page 17: ...e not to weaken the posts 14 mm x axe du gond Depending on the maximum opening angle desired for the gate the post bracket should be placed further from or nearer to the edge of the post so that the m...

Page 18: ...GATES CONNECT EN 18 w w w m y t h o m s o n c o m Position the bracket on the post using distance X and mark the locations of the holes 37 mm 115 mm 12 mm x 12mm bit for 12 plugs Open the cover of th...

Page 19: ...homson com MOTOR DRIVE FOR 2 PANEL GATES CONNECT Fasten the motors on the mounting brackets Screw 11 Washer 18 Spring washer 17 Nut 16 Assemble the pivoting arms and motors Washer 12 Washer 14 Screw 1...

Page 20: ...the arms 75cm Close the gate by pressing it firmly against the central stop Position the pivoting arms against the gate at a distance of 75cm and mark the location of the holes on the gate Important T...

Page 21: ...nuts that are suitable for the gate material Reassemble the end of the arm and the gate bracket Important At this point in the installation the motors are disengaged The gate may be set in motion by...

Page 22: ...gate where the ends of the pivoting arms will be fastened 1m maximum recommended 14mm Inner side of the property Use plugs and screws that are suitable for the post material example for concrete use 1...

Page 23: ...23 EN EN www mythomson com MOTOR DRIVE FOR 2 PANEL GATES CONNECT C INSTALLATION 37 mm 115mm 12 mm 12mm bit for 12 plugs Open the cover of the motors...

Page 24: ...RIVE FOR 2 PANEL GATES CONNECT EN 24 w w w m y t h o m s o n c o m Fasten the motors on the mounting brackets Screw 12 Nut 16 Assemble the pivoting arms and motors Washer 14 Washer 20 Screw 13 C INSTA...

Page 25: ...euvre the arms Open the gate up to the side stops Turn the pivoting arm to press the gate bracket against the gate as far as possible from the hinges Mark the holes for fastening the bracket on the ga...

Page 26: ...gate Use screws and nuts that are suitable for the gate material Reassemble the end of the arm and the gate bracket Important At this point in the installation the motors are disengaged The gate may b...

Page 27: ...thout support With a screwdriver remove the transparent part of the flashing light by unscrewing the 2 screws that hold the upper part of the flashing light Still with a screwdriver remove the flashin...

Page 28: ...must be perfectly flat in order to properly align the infrared beam of the photocells Place the photocells at exactly the same height from the ground they must be perfectly aligned and parallel to eac...

Page 29: ...tall the reception photocell RX indicated on the back on the motor post containing the electronic card The surface of the posts must be perfectly flat in order to properly align the infrared beam of t...

Page 30: ...otocells must be perfectly aligned and parallel to each other The reception photocells RX indicated on the back must be installed facing the motor post where the electronic card is located see drawing...

Page 31: ...FOR 2 PANEL GATES CONNECT C INSTALLATION 30cm mini 60cm maxi RX1 RX1 pair 1 pair 1 pair 2 pair 2 10 cm min 15 cm max 10 cm min 15 cm max TX1 TX1 90 90 90 90 RX2 RX2 TX2 TX2 Opening inwards view from...

Page 32: ...Vac Safety instructions All electrical connections must be performed with the power switched off safety switch in OFF position and the battery disconnected These connections must be made by a qualifie...

Page 33: ...warn 2B M2 M1 The motor that opens first must be connected to the M1 output of the electronic card Black Red For outward opening with the motor mounted on the left post view from inside OR For inward...

Page 34: ...e connector between GND and PHO With one set of photocells remove the connector between GND and PHO photocell RX1 photocell TX1 BAT TRANS GND GND PHO 24V M1 M2 M1 M2 warn warn 2B NO COM NC With 2 sets...

Page 35: ...that you check the range To do so place your micro module as close as possible to its final location before you attach it and test your accessory Connect the dry contact output wires as on the diagra...

Page 36: ...y the application Once you have entered your e mail and password you will receive a confirmation code in your e mail inbox Enter this code to finalise the registration The module is in pairing mode by...

Page 37: ...the wifi network to which the Guardian module will be connected insert your network password and press NEXT Please wait during the pairing procedure This stage can take several minutes In case of fai...

Page 38: ...sistants If you want to give access to your family they must download the At Home application and connect to the account on which the module is saved For more details and other features download the f...

Page 39: ...sible to connect a backup battery to perform some manoeuvres in the event of power failure Type of battery NiMH Battery voltage 24V Configuration 20xAAA 800mAh Use the connection cable supplied in the...

Page 40: ...to the same connector as the backup battery The solar power kit which already has a battery and a backup battery cannot be connected at the same time For installation refer to the solar power kit inst...

Page 41: ...ou are at MENU 0 of the display press on PROG 2 or 3 times and only the green LED should be switched on When the user performs no action on a button for 15 seconds the system automatically goes back t...

Page 42: ...glage temps augmente le temps diminue le temps OK MENU 0 r glable de 0 4 MODE 1 pas de fermeture auto MODE 2 fermeture auto MODE 3 mode collectif force des moteurs mode de fonctionnement temps de temp...

Page 43: ...pressing the gate or pedestrian command The gate stays open and you must press the gate command to close the gate While the gate is in motion you can stop it by pressing the gate or pedestrian command...

Page 44: ...t the force be reduced Note To meet the requirements of Standard 12453 it may be necessary to change the force of the motors To adjust the force follow the procedure below Press PROG for 3 seconds L0...

Page 45: ...M1 starts to open gradually accelerating Panel M2 starts to open gradually accelerating 2 5 seconds or more depending on the setting see MENU 3 after M1 The panels reach their opening stops Panel M2...

Page 46: ...learning procedure and assist the panel opening process during the start of phase 2 if wind speed remains high Note 2 many possible causes The motor was not recognised as compatible with the electron...

Page 47: ...otor Press simultaneously on both buttons at the bottom of the remote control already in the memory until the flashing light switches on around 6 seconds Press any button on the new remote control The...

Page 48: ...pour r gler la valeur OK MENU 0 0 inactives en d but d ouverture par d faut 1 actives en d but d ouverture 0 portail 2 battants par d faut 1 portail 1 battant portillon L1 L2 L3 L4 L1 L2 L3 L4 L1 L2...

Page 49: ...K to confirm All LEDs will turn on and off to confirm the operation 3 2 3 Type of gate To operate the electronic card on a single panel gate this setting must be changed By default this value is set t...

Page 50: ...on Self learning is required if this setting is changed 3 3 Advanced settings menu MENU 3 D calage fermeture OK PROG R glage temps augmente le temps diminue le temps OK MENU 0 0 2 5 sec par defaut 1 3...

Page 51: ...et the gate in motion is received by the electronic card The gate is set in motion around one second after a command is received In certain use cases it is better that the time between receiving a mot...

Page 52: ...ol devices Prevent children from playing near or with the motorised gate Do not deliberately stop the moving gate except of course with a control device or for an emergency stop Prevent any natural ob...

Page 53: ...econd 1 second later panel M1 starts opening 2 5 seconds later panel M2 starts opening Both panels open up to their opening stop When the two panels have reached their opening stop the flashing light...

Page 54: ...ty purposes if the motors are under too much strain the force is adjustable see Motor Force in the settings the gate stops and releases the pressure and the flashing light emits double flashes for 30...

Page 55: ...rting work you must attach a sign to the disconnection device The first check must be carried out 1 month after installation to check that all the instructions have been followed Points to check The w...

Page 56: ...t has a different code This code is displayed by a combination of red LEDs that are on off or flashing on the MENU 0 display When OK or PROG are pressed this code is deleted However the last 4 codes g...

Page 57: ...g opening Check the gate movement area E Three obstacles detected in a row during closing Check the gate movement area E The main power supply has been cut during a movement phase OR the battery is to...

Page 58: ...s unobstructed If a wired control device is connected to input 2B LED L2 turns on when the contactor of the component is activated 2 3 Total reset You can reset to factory settings To do so press and...

Page 59: ...omson com MOTOR DRIVE FOR 2 PANEL GATES CONNECT F MAINTENANCE AND UPKEEP Close the remote control and screw in the fastening screws 2 5 Replacing the power fuse Switch the motor drive off Use a 250V 5...

Page 60: ...and for a temperature of 20 C The company avidsen reserves the right to modify these characteristics at any time while under all circumstances guaranteeing these products smooth operation and the type...

Page 61: ...current after start 5A Flashing light output Flashing controlled by the electronic card For 24V flashing light with LED only included in the kit Power output To power the photocells 3 3W maximum 2 se...

Page 62: ...of 10 x 2s uses per day Operating temperature 20 C 60 C Protection rating IP40 For indoor use only home car or sheltered location PHOTOCELLS Type Modular infrared beam presence detector D type safety...

Page 63: ...or invoice is proof of purchase date 4 ASSISTANCE AND ADVICE If despite the care we have taken in designing our products and drafting these instructions you do encounter difficulties when installing...

Page 64: ...oned product complies with the RED 2014 53 EU directive Its conformity has been assessed pursuant to the applicable standards in force EN 62368 1 2014 A11 2017 ETSI EN 301 489 1 V2 2 3 2019 ETSI EN 30...

Reviews: