background image

AllClear

™ 

G2 Series 

Pressurized Filters

Product Manual

TM

For Models:

• AllClear™ G2 2000

 

(Item #130050)

• AllClear™ G2 3500

 

(Item #130051)

• AllClear™ G2 4500

 

(Item #130052)

TM

Important Information. . . . . . . . . . . . . . . . . . . . . . . . 2

Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

How it Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Installing Your AllClear™ G2 Filter. . . . . . . . . . . . . 5-6

Maintaining Your AllClear™ G2 Filter  . . . . . . . . .  7-11

Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Replacement Parts  . . . . . . . . . . . . . . . . . . . . . . . 14-15

Warranty Information. . . . . . . . . . . . . . . . . . . . . . . . 16

Table of Contents:

AllClear™ G2 2000

AllClear™ G2 3500

AllClear™ G2 4500

Summary of Contents for AllClear G2 2000

Page 1: ...m 130051 AllClear G2 4500 Item 130052 TM ImportantInformation 2 PackageContents 3 TechnicalSpecs 3 HowitWorks 4 InstallingYourAllClear G2Filter 5 6 MaintainingYourAllClear G2Filter 7 11 Troubleshooting 12 ReplacementParts 14 15 WarrantyInformation 16 Table of Contents AllClear G2 2000 AllClear G2 3500 AllClear G2 4500 ...

Page 2: ...tts than the unit rating DO NOT immerse the AllClear G2 Filter or plug in water or attempt to use a wet plug Minimum safety distance between unit and water is 6 5ft The AllClear G2 Filter is NOT suitable for use in swimming pools swimming ponds or other situations where bodily contact is made with the water Although the AllClear G2 Filter is designed for outdoor use it should never be submerged in...

Page 3: ...NS AllClear G2 2000 120V 60 Hz 9Watts 2 000 GPH 2 000 1 1 Kink FreeTubing 16 15 D x 16 1 2 H AllClear G2 3500 2 650 GPH 3 500 15 D x 21 1 4 H AllClear G2 4500 3 600 GPH 4 500 15 D x 26 1 2 H AllClear G2 Series A AllClear G2 Filter B Fitting Kit C Backflush Cap may already be installed on backflush outlet A B C 15425 Chets Way Armada MI 48005 3 ...

Page 4: ...efits Next water travels through layers of filter media arranged in alternating low and high density to provide mechanical and biological filtration The beneficial bacteria that grow in the media pads break down ammonia and nitrites that can diminish water quality and be harmful to aquatic life Finally the water exits the filter and proceeds back into your pond or waterfall thepondguy com 866 POND...

Page 5: ...cation The AllClear G2 Filter is pressurized and may be installed in any location outside of the pond on a solid surface Avoid locations that are prone to water puddles or areas where the filter could fall into the pond It is recommended to partially bury the filter in the ground leaving only the filter top and clamps exposed Step 2 Mark Filter Location Set the filter in the selected location and ...

Page 6: ...work with your plumbing to ensure maximum water flow Step 6 Connect the Plumbing Connect the plumbing coming from your pump into the inlet indicated on the filter and secure with a hose clamp Then connect plumbing that will return the water to your pond or waterfall into the outlet indicated on the filter and secure with a hose clamp Step 7 Plug in Pump and Filter Plug your pump into a GFCI protec...

Page 7: ...lter slowly This compresses the filter media aiding in the discharge of debris Do this for 60 seconds or until the water exiting the backflush is clear MAINTAINING YOUR ALLCLEAR G2 FILTER Step 4 Once Water is Clear Unplug Pump Once the water is clear unplug the pump remove the discharge hose and cap the backflush outlet Step 5 Plug Pump In Restore power to both your pump and filter CLEANING THE FI...

Page 8: ...ns of wear and tear WARNING Before performing any maintenance always unplug the AllClear G2 Filter from the power source Watch a video of the AllClear G2 Filter maintenance online www thepondguy com allclearg2 Tools Required 2 Phillips Screwdriver Replacement UV Bulb Soft damp cloth Descaler such as Pond Equipment Cleaner Replacement quartz sleeve if yours is damaged or cracked Replacement filter ...

Page 9: ... Use a phillips screwdriver to remove the 4 screws securing the UV to the filter top REPLACING UV BULB AND CLEANING REPLACING THE QUARTZ SLEEVE Over time the effectiveness of the UV bulb will degrade We recommend replacing the UV bulb once a year even if the bulb operates to maintain maximum results The quartz sleeve should be cleaned yearly or when water clarity is reduced Note Condensation may f...

Page 10: ...e oils from your hands can cause damage Step 6 Clean Quartz Sleeve Clean the quartz sleeve with a soft cloth or sponge The quartz sleeve should be cleaned yearly or when water clarity is reduced You may find the use of Pond Equipment Cleaner helpful for removing debris If the quartz sleeve if it is scratched damaged or cracked it must be replaced Step 5 Transfer Protective Cap Transfer the rubber ...

Page 11: ...all the o ring quartz sleeve compression nut and screw to lock into place Step 8 Insert UV into Filter Insert the UV back into the filter top and secure with the 4 screws Note Screws must be tightened enough to engage the UV trigger you will hear a click when the UV is secure Step 9 Test UV Plug in the UV briefly to test it You will see a glow on the back of the UV indicating that it is operating ...

Page 12: ...ndation for proper water flow on the Technical Specs chart Verify that filter media is not plugged with debris or needs cleaning Loss of water flow check the following Verify pump is not plugged with debris Verify filter media is not plugged with debris Verify filter is not leaking causing a loss of pressure Filter is leaking check the following Verify that the proper amount of water is flowing th...

Page 13: ...NOTES 15425 Chets Way Armada MI 48005 13 ...

Page 14: ...lClear G2 4500 A FilterTop Lid 130082 130082 130082 B UVTransformer 130095 130089 130096 C 9W UV Bulb 110306 110306 110306 D Quartz Sleeve 130074 130074 130074 I Operating Pieces 130090 130090 130090 J Gasket Kit 130087 130087 130087 K Screw Set 130091 130091 130091 L Fitting Kit 130088 130088 130088 M PVC Fitting Kit 130036 130036 130036 thepondguy com 866 POND HELP 766 3435 14 ...

Page 15: ...ear G2 4500 E Cleaning Rods MeshTube 130092 130093 130094 F Filter Pad Set 130055 130056 130057 G Canister Clamp 130086 130086 130086 H Filter Canister Clamp w Filter Pads 130083 130084 130085 I Operating Pieces 130090 130090 130090 J Gasket Kit 130087 130087 130087 K Screw Set 130091 130091 130091 15425 Chets Way Armada MI 48005 15 ...

Page 16: ...eipt The UVC bulb glass tube filter media and o rings are wearable items and are not covered by this warranty Abuse or misuse of this product or power cord alterations void all warranty Please call for a Return Authorization Number prior to returning product by calling our Customer Care Department at 866 766 3435 Failure to request an RMA number may result in delay or dismissal of your warranty cl...

Reviews: