background image

SUMMARY

REVISION OF THE MANUAL.................................................................................3

INTRODUCTION.....................................................................................................4

1  

 LEGEND OF THE SYMBOLS USED.................................................................5

2  

 SPECIFIC SAFETY RULES FOR INSTALLING TMD MK0...............................7

2.1  

 Glossary..................................................................................................................7

2.2  

 General Rules..........................................................................................................8

2.3  

 Operator Safety.......................................................................................................9

2.4  

 Device Safety........................................................................................................10

2.5  

 Safety during the Installation.................................................................................11

3  

 OPERATION OF THE RADIO DEVICES.........................................................12

4  

 ENVIRONMENTAL INFORMATION................................................................13

5  

 REGULATORY INFORMATION.......................................................................14

6  

 TMD MK0.........................................................................................................15

7  

 DESCRIPTION.................................................................................................16

8  

 TECHNICAL FEATURES.................................................................................17

9  

 TMD MK0 INSTALLATION AND POWER SUPPLY........................................19

9.1  

 Indications if not used for a long time....................................................................22

10  

 ACTIVATION AND CONFIGURATION..........................................................23

10.1  

 Activation through MK3Starter.............................................................................23

10.2  

 Configuration through the Portal..........................................................................23

11  

 MAINTENANCE.............................................................................................24

12  

 LEGAL NOTICES...........................................................................................25

1

Summary of Contents for TMD MK0

Page 1: ...during the Installation 11 3 OPERATION OF THE RADIO DEVICES 12 4 ENVIRONMENTAL INFORMATION 13 5 REGULATORY INFORMATION 14 6 TMD MK0 15 7 DESCRIPTION 16 8 TECHNICAL FEATURES 17 9 TMD MK0 INSTALLATION AND POWER SUPPLY 19 9 1 Indications if not used for a long time 22 10 ACTIVATION AND CONFIGURATION 23 10 1 Activation through MK3Starter 23 10 2 Configuration through the Portal 23 11 MAINTENANCE 24 12...

Page 2: ...2 ...

Page 3: ...TMD MK0 INSTALLATION MANUAL REVISION OF THE MANUAL This document is revision 01 of the TMD MK0 operating manual Issue Date 30 06 2020 3 ...

Page 4: ...nded to offer technical training of any kind and technicians will therefore carry out any interventions under their own responsibility and will be accountable for any damage or personal injury caused by negligence carelessness or inexperience regardless of the fact that a TEXA S p A tool has been used based on the information within this manual Any additions to this manual useful in describing the...

Page 5: ...hazard Flammable material hazard Hot surface hazard Corrosive substance hazard Risk of noise level above 80 dbA Moving Parts Risk Risk of crushing hands Floor level obstacle warning Laser beam hazard General Risk Obligation to read the instructions This is not a safety symbol It indicates a hazardous situation which if not avoided will result in serious permanent injury or death 5 ...

Page 6: ...anent injury or death This is not a safety symbol It indicates a hazardous situation which if not avoided may result in minor injury This is not a safety symbol It indicates a hazardous situation which if not avoided may result in material damage This is not a safety symbol It indicates important information 6 ...

Page 7: ...intended use only and to carry out maintenance correctly as described in this manual All the requirements based on the following must be assessed and applied Labour inspectorate Trade associations Vehicle manufacturers Anti pollution regulations 2 1 Glossary Operator a qualified person responsible for installing the remote diagnostic device Device any TMD MK0 device The definition of operator cann...

Page 8: ... when installing and operating the device is strictly forbidden The operator must follow all the instructions provided in the technical documents The operator is required to wear adequate personal protective equipment PPE throughout the installation of the device The operator must periodically check the electrical connections of the device making sure they are in good condition and immediately rep...

Page 9: ...andle or touch the device or any accessories e g cables with wet hands If liquid should penetrate inside the device immediately disconnect the power supply wiring and contact technical assistance Do not wear metal rings or bracelets when working on batteries The device was manufactured to be electrically safe and mechanically resistant However it is necessary to reduce the risk of damages to the d...

Page 10: ...er supply may impair its efficiency Safety Measures Do not wet the device with water or other liquids The device s power supply must always be connected following the indications provided in this manual Do not use external batteries to power the device Wear the most suitable personal protective equipment to avoid static electricity The device was designed to be used in specific environmental condi...

Page 11: ...tioning Safety Measures Insulate each of the device s connections to the vehicle s electrical system Do not compromise in any way the quality of the electrical and mechanical OEM wiring Make sure the electric cables the wiring in general the fuel hydraulic pipes and the safety pneumatic devices of the vehicle are not damaged during the installation Do not change the current flow of an OEM circuit ...

Page 12: ...ct and only prompt you with compatible TEXA devices This does not exclude the presence of other sources of communication or disturbance THE EFFICIENCY AND QUALITY OF BLUETOOTH WiFi AND 2G 3G 4G COMMUNICATION MAY BE INFLUENCED BY THE PRESENCE OF RADIO DISTURBANCE SOURCES THE COMMUNICATION PROTOCOL HAS BEEN DEVELOPED TO MANAGE THESE TYPES OF ERRORS HOWEVER IN THESE CASES COMMUNICATION MAY BECOME DIF...

Page 13: ...4 ENVIRONMENTAL INFORMATION Do not dispose of this product with other undifferentiated solid waste For information regarding the disposal of this product please see the pamphlet supplied 13 ...

Page 14: ...ed EU Declaration of Conformity TEXA S p A declares that the TMD MK0 type of equipment is compliant with the following directives RED 2014 53 EU The full text of the EU declaration of conformity is available by contacting TEXA S p A 14 ...

Page 15: ...d send a vehicle s data to a remote server The TMD MK0 Kit includes TMD MK0 Wiring for the electrical connection code 3910308 Double sided tape for fastening the device code 3910673 The data relating to detected alarms and positions can be viewed in the TMD portal 15 ...

Page 16: ...7 DESCRIPTION 1 Device 2 Power cable 3 Power cable 4 Power cable connector 16 ...

Page 17: ...from vehicle battery 12 24 Vdc 200 mA maximum Operating temperature 30 70 C 30 75 C without internal battery Storage temperature 30 80 C Battery recharging temperature 20 70 C Operation moisture 10 80 Dimensions Weight 121 g IP protection level IP 67 Regulations and Directives ECE ONU R10 RED 2014 53 EU RoHS 2011 65 EU Electromagnetic Compatibility ETSI EN 301 489 1 ETSI EN 301 489 3 ETSI EN 301 4...

Page 18: ...Radio Systems ETSI EN 300 328 ETSI EN 301 511 ETSI EN 300 440 EN 62311 Electrical Safety EN 62368 1 18 ...

Page 19: ...e is off instrument panel off when connecting the device to the battery terminals Periodically check that the connectors wiring and supplied cables are undamaged If the connectors wiring and cables are damaged contact the assistance service for a replacement For any malfunction contact the assistance service Clean the surfaces using an alcohol based solution before applying double sided tape 19 ...

Page 20: ...urface 4 Connect the device s red cable to the battery positive terminal 12V 24V 5 Connect the device s black cable to the battery negative ground terminal Do not remove the device by pulling the power supply cables Make sure the 12V 24V and ground connections are correct in order to avoid the arising of false alarms from the TMD MK0 discharged battery alarm power disconnection alarm 20 ...

Page 21: ... whether the vehicle is travelling or not The device identifies its orientation with respect to the vehicle s driving direction with an automatic learning procedure The inertial data is not used until the procedure is complete All the configured functions that require use of the inertia sensors are automatically enabled at the end of the procedure 21 ...

Page 22: ...gnition off TMD MK0 is designed to optimise consumptions however if the vehicle is not used for a long period of time it could sensibly lower the charge level of the battery If the vehicle is not used for a long period of time you may disconnect TMD MK0 from the power supply For more information contact TEXA S p A assistance service 22 ...

Page 23: ...e MK3Starter the device the app is installed in must connect to the Internet and be enabled to install apps coming from unknown creators The device can be configured at the end of the activation procedure For further information consult the MK3Starter operating manual 10 2 Configuration through the Portal The device can be configured remotely through the TMD portal The portal may be used to eventu...

Page 24: ...ys from the installation of the TMD MK0 and then every 6 months In particular Carry out a visual inspection of the installed device Check for possible damages to the device wrongly fixed covers plastic parts cut off and or damaged cables unhooked and or loose connectors Make sure the connections are not damaged oxidised exposed to atmospheric agents water and humidity Make sure TMD MK0 is fastened...

Page 25: ...ubject to the direction and coordination activities of Opera Holding S r l Paid up share capital 1 000 000 R E A Economic Administrative Index No 208102 Legal Representative Bruno Vianello Phone 39 0422 791 311 Fax 39 0422 791 300 www texa com For information regarding the legal notices please refer to the International Warranty Booklet provided with the product 25 ...

Reviews: