background image

Tenma Model 72-7655

 

High Current Switch Mode Power Supply with Remote Sensing and Control

User Manual

1.

       INTRODUCTION

 

 

This  900W  switching  mode  DC  regulated  dual  output  power  supply  series  provides  high  current  with
constant  current  limiting  protection

, and va

riable  output

 of 

1

.0 

~ 15V

DC.

  It is designed with a high

ly

 efficient

 Active Power Factor Corrector. The remote sensing terminal is

 

used to compensate for long output line losses.

The output voltage level can be externally controlled via th

remote control terminal.

2.

       PRECAUTIONS

 

 

   

Never Short the Remote Sensing Terminal

This power supply is for Indoor Use Only.

 

  Do not

 expose the power supply to sun, humid 

or 

dusty environment.

Never

 remove the metal cover of the power supply while AC power is connected.

Never

 touch the unit when your hands are wet.

Never

 block the ventilation slots and cooling fan air intake window  

Never 

attempt to repair the power supply. Incorrect re-assembly may result in a risk of electric shock or

fire.

Never

 use the power supply for the load requiring higher current than the designed value otherwise it

may damage the power supply.

Place  the  power  supply  on  a flat  surface  with  sufficient  clearance,  dry, dust  free  surroundings  for
ventilation.

3.

       CONTROLS AND INDICATORS

 

 

(1)

  Voltage & Ammeter LED Display

(2)

Overload LED Indicator – Overload(Constant Current Limiting) & Short-Circuit Protection

(3)

Output Voltage Control Knob(control both main and auxilary output)

(4)

Power ON/OFF Switch

(5)

Power ON/OFF LED

(6)

Auxiliary Output Terminal

Rated 5A 

(7)

Main Output Terminal

Rated 60A 

(8)

Remote Sensing Terminal 

(Warning! : Never short the remote sensing terminal)

(9)

Remote Control Terminal

(10)

Remote Control ON/OFF Switch

(11)

Cooling Fan Air Intake Grille

(12)

AC Input Plug

Front

Rear

Note: Main and Auxiliary output give out same output voltage

CAUTION! : The AC Input is DOUBLE POLE FUS

ED

 

Summary of Contents for 72-7655

Page 1: ...ventilation slots and cooling fan air intake window Never attempt to repair the power supply Incorrect re assembly may result in a risk of electric shock or fire Never use the power supply for the load requiring higher current than the designed value otherwise it may damage the power supply Place the power supply on a flat surface with sufficient clearance dry dust free surroundings for ventilatio...

Page 2: ...plete the power connections between power supply and equipment 2 Check and make sure the power connections are secure 3 Then make connections between Remote Sensing and equipment Warning Never short the Remote Sensing Terminal Dis connection 1 First disconnect the remote sensing connections 2 Then disconnect the power connections between the power supply and equipment Fig 3 showing connections bet...

Page 3: ...F ii Use ONLY wires from port 2 and 3 Then connect port 2 to positive polarity of the external voltage source and port 3 to negative polarity of the external voltage source iii Turn the Remote Control ON OFF Switch to ON position iv Switch on the power supply v Vary the external input voltage 0 5V to check and verify for the full output voltage range of power supply vi Switch off the power supply ...

Page 4: ...perate the equipment When an operation is finished switch off the equipment first and then switch off the power supply 4 11 When disconnecting the power supply from the unit disconnect the remote sensing wire first then disconnect the output cables 5 SPECIFICATIONS Variable Output Voltage 1 15V Total Rated Output Current Main Auxiliary Output 60A Rated Output Current Main 60A Rated Output Current ...

Reviews: