background image

 

 

 
 
 
 
 
 
 

FM5500 User Manual 

V2.08 

 

 

 

 
 
 
 
 
 

This  manual is suitable for device with firmware v.01.03.xx and later versions

 

Summary of Contents for FM5500

Page 1: ...FM5500 User Manual V2 08 This manual is suitable for device with firmware v 01 03 xx and later versions...

Page 2: ...TATUS LED 18 3 5 SOCKET 2 10 PINOUT 19 3 6 USB 20 3 7 ACCESSORIES 20 4 FIRMWARE 24 4 1 UPDATING FIRMWARE USING USB CABLE 24 5 OPERATIONAL BASICS 26 5 1 OPERATIONAL PRINCIPLES 26 5 2 OPERATIONAL MODES...

Page 3: ...NDENCE ON GSM OPERATOR 59 7 2 PROFILE SWITCHING DEPENDENCE ON I O EVENT 61 Example 1 62 Example 2 62 8 DUAL SIM FUNCTIONALITY 63 Home Network 64 SIM 1 Roaming 65 SIM 2 Roaming 65 Unknown Operator 66 D...

Page 4: ...PS 88 13 9 LOADPROFILE 88 13 10 CPURESET 88 13 11 RESETALLPROF 88 13 12 GETVER 89 13 13 GETIO 89 13 14 GETINFO 89 13 15 DELETERECORDS 90 13 16 READIO 90 13 17 SETDIGOUT X Y Z W 90 13 18 GETPARAM 90 13...

Page 5: ...N INFO BY SMS 127 15 9 REFERENCES 127 16 RS485 INTERFACE 127 16 1 RS485 MODES 127 RS485 Receive Silent Mode 128 RS485 Receive TCP Link Mode 129 RS485 Receive LLS Mode 129 RS485 Transmit FM Log Mode 12...

Page 6: ...ied personnel The device must be firmly fastened in the predefined location The programming must be performed using a second class PC with autonomic power supply The device is susceptible to water and...

Page 7: ...2 Teltonika All rights reserved Reproduction transfer distribution or storage of part or all of the contents in this document in any form without the prior written permission of Teltonika is prohibite...

Page 8: ...ardboard box containing all the equipment that is necessary for operation The package contains FM5500 device Input and output power supply cable with 2x10 connection pins 4 screws for assembling devic...

Page 9: ...tions Test Load Dump for the 12V systems Us 101V td 0 4s Ri 4Ohm and for the 24V system Us 202V td 0 35s Ri 8Ohm Interface features USB port 4 digital inputs 4 analog inputs 4 open collector digital o...

Page 10: ...orage temperature 40 C 70 C Storage relative humidity 5 95 non condensating Modem LED LED GPS GPS antenna connector MCX GSM GSM antenna connector SMA female outer shell female inner pin Socket 2x10 Ty...

Page 11: ...500 has two modifications GPS GLONASS and GPS Figure 2 refers to GPS GLONASS modification and Figure 3 refers to GPS modification of FM5500 Figure 2 FM5500 sticker for GPS GLONASS modification Figure...

Page 12: ...of FM5300 allows to connect additional external backup battery Such FM5300 modification should be purchased by special order Contact sales manager for details Operating from backup accumulator Uext Ub...

Page 13: ...25 2V all modules fully working internal battery is charging Icc3 158 mA Ucc 25 2V all modules fully working internal battery is charged Icc4 123 mA SUPPLY CURRENT HARDWARE VERSION WITH EXTERNAL BATTE...

Page 14: ...inner resistance 7 Ohm Output current Uout 3 0V 30 mA Short circuit current Uout 0 130 mA CAN INTERFACE Internal terminal resistors CAN bus No Ohm Differential input resistance 19 30 52 kOhm Recessiv...

Page 15: ...m Ratings Idrain 2mA 36 V Digital Input Voltage Absolute Maximum Ratings 32 32 V Analog Input Voltage Absolute Maximum Ratings 32 32 V Voltage on Supply Voltage 1 Wire Absolute Maximum Ratings 0 10 V...

Page 16: ...0 case and insert SIM cards as shown SIM SLOT 1 default recommended for 1 SIM mode is closer to PCB SIM SLOT 2 is the upper one Assemble device as shown and put screws into the holes Screw all 4 screw...

Page 17: ...er_v1 3 1_setup zip Installing drivers Extract and run VCPDriver_V1 3 1_Setup exe This driver is used to detect FM5500 device connected to the computer Click Next in driver installation window figures...

Page 18: ...eceived Blinking every second Normal mode GPS is working Off GPS is turned off because Deep sleep mode Or GPS antenna short circuited 3 4 Status LED Table 5 Status LED Operation Behaviour Meaning Blin...

Page 19: ...AIN 2 Analog input channel 2 Input range 0 30V 0 10V DC 8 OUT 3 Digital output Channel 3 Open collector output 9 OUT 2 Digital output Channel 2 Open collector output 10 Ext Battery 1 For FM5500 with...

Page 20: ...e external battery 3 6 USB When FM5500 is connected to a PC it creates a STM Virtual COM Port which can be used as a system port to flash firmware and configure the device Figure 8 COM Ports 3 7 Acces...

Page 21: ...S1990A Figures 9 and 10 show FM5500 and 1 wire devices connection schemes Left row of pins 1 3 4 1 2 2 J1 J2 J3 U1 Right row of pins 1W PWR FM5500 pin3 1 1W Data FM5500 pin13 2 1 Vpp 5 Volts DC power...

Page 22: ...scheme to the FM5500 and fuel tank sensor After the connection to the tank fuel level sensor calibration is needed Calibrations needed due of the fact that most fuel tank sensors are not linear Calibr...

Page 23: ...onal relay has to be installed to convert negative signal to positive Figure 13 Inverting relay connection Immobilizer relay When connected a shown below FM5500 disables engine starter when output is...

Page 24: ...C with the USB cable Launch Firmware Updater select COM port to which device is connected click connect and when IMEI and Firmware version fields are filled start the update Device needs some time to...

Page 25: ...25 Figure 16 FM5500 firmware updater screen...

Page 26: ...PS receiver to acquire GPS data and is powered with 3 data acquire methods time based distance based and angle based Method s details are described in Data Acquisition chapter 9 All data is stored in...

Page 27: ...change on X Y and Z axes If measured g force keeps exceeding the set limit it is not configurable for defined time interval in Movement Filter Start field Figure 12 then the vehicle is considered as...

Page 28: ...includes settings for Microphone level to regulate microphone sensitivity and Speaker level to define how loud will be the speaker Figure 19 Voice and Call Settings 5 6 Profiles FM5500 has 4 profiles...

Page 29: ...ent from exceeding fixed speed and inspects driver if needed DOUT1 is controlled by scenario for user needs to manage buzzer LED etc Authorized Driving Scenario Gives ability to use vehicle only for 5...

Page 30: ...anager to get the latest FM5500 Configurator version FM5500 configurator operates on Microsoft Windows OS and uses MS Net Framework 3 5 or higher Please ensure that MS Net Framework 3 5 or later is in...

Page 31: ...rea Settings menu Configurable parameters and values menu Figure 21 FM5500 Configurator window structure Buttons area Table 7 Configurator buttons area description Main Buttons Button Description Conn...

Page 32: ...tor security SIM PIN STATUS status of SIM card in the device Profiles global parameters selection area FM5500 has 4 user editable profiles stored in Flash no 1 4 memories and one extra profile stored...

Page 33: ...ofiles and Global parameters are saved to the Flash Figure 23 Figure 23 FM5500 Configurator profiles saving information 6 3 Parameters Configuration Global parameters Settings Global parameters do not...

Page 34: ...onds should FM5500 keep connection to the server before disconnecting after successful data transfer Note that even if it disconnects from server it always keep active GPRS session Analog input settin...

Page 35: ...nicode SIM 1 GPRS Settings Allows to insert SIM 1 APN APN user name and APN password SIM 2 GPRS Settings Allows to insert SIM 2 APN APN user name and APN password Settings and configurable parameters...

Page 36: ...ax Upload in Home and Roaming Max Upload in Roaming Separately Currently Min Settings for Home and Roaming are 10MB User can choose to get SMS notification if Data limit has been reached SMS is send o...

Page 37: ...ord are not set getgps Phone numbers have to be written in international standard without using or 00 signs in prefix If no numbers are entered in configuration then commands SMS are allowed to be sen...

Page 38: ...e tab 24 Coordinates SMS decoding is described in FM5500 Protocols document 6 3 1 2 4 Operator List FM5500 is able to use GPRS with all operators but if at least one operator is entered in the list FM...

Page 39: ...gain after defined time interval GPRS Context Week Time tab most GSM billing systems charge number of bytes kilobytes transmitted per session During the session FM5500 makes connection and transmits d...

Page 40: ...rameters are shown in Figure 31 All values of these parameters are described in chapter 12 Figure 31 FM55 Features Scenarios Configuration 6 3 1 3 3 Trip Trip window offers user to configure Trip feat...

Page 41: ...O Odometer is enabled and Continuous Distance Counting variable is set to Not then distance is going to be counted only between every record made This value is written to I O Odometer value field and...

Page 42: ...low high or panic SW21 SW22 SW23 SW24 These levels define priority of event information sending to server See I O element description for more details about priorities Generate event On entrance On ex...

Page 43: ...dropped Priority Priority of generated event which will be applied to saved record Generate Event Enter Event Event generation on Geofence entrance Exit Event Event generation on Geofence exit On Both...

Page 44: ...escription 1 Digital Input Status 1 1 Logic 0 1 2 Digital Input Status 2 1 Logic 0 1 3 Digital Input Status 3 1 Logic 0 1 4 Digital Input Status 4 1 Logic 0 1 5 Analog Input 1 2 Voltage mV 0 30 V 6 An...

Page 45: ...r on COM1 in kvants or liters 35 Fuel temperature 1 1 Fuel temperature measured by LLS sensor on COM1 in degrees Celsius 36 Fuel level meter 2 2 Fuel level measured by LLS sensor on COM2 only in kvant...

Page 46: ...ofence 1 Event 0 target left zone 1 target entered zone 22 SIM 1 IMSI 4 6 last numbers of SIM 1 IMSI 23 SIM 2 IMSI 4 6 last numbers of SIM 2 IMSI 24 Active SIM slot 1 0 Active SIM 1 slot 1 Active SIM...

Page 47: ...L packet using SMS mode if SMS is enabled in SMS settings Then it switches its operating profile to Profile 4 for details see chapter 8 1 SW2X priorities switch profiles on event SW21 Profile 1 SW22 P...

Page 48: ...Value type 0 1 I O 0 priority ID 301 I O 0 High level ID 302 I O 0 Low level ID 303 I O 0 logic operand ID 304 I O 0 averaging constant ID 305 S8 I O 0 priority ID 301 Parameter defines I O property t...

Page 49: ...I O 0 logic operand ID 304 Parameter defines when event is sent 0 is event on exit 1 on entrance 2 on both 3 monitoring 4 hysteresis 5 on change Table 17 I O Logic Operand Minimal value Maximum value...

Page 50: ...27 Area Code 570 575 I O 11 Fuel level meter 1 410 415 I O 28 PCB Temp 580 585 I O 12 Fuel temperature 1 420 425 I O 29 Dallas Temp 1 590 595 I O 13 Fuel level meter 2 430 435 I O 30 Dallas Temp 2 60...

Page 51: ...Output data mask Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 FF CAN 0 CAN Type ID ID 770 CAN 0 CAN ID ID 772 U8 CAN 0 CAN ID ID 772 Parameter defines CAN...

Page 52: ...6 3 1 6 Configurable parameter values and Global parameter values 6 3 1 6 1 Configurable parameters Table 25 Configurable parameter values Parameter ID Parameter value Value type MIN MAX Default Recom...

Page 53: ...tangle None Circle 036 90 90 0 Float AutoGeofencing parameters chapter 6 3 1 3 4 2 Deactivate By 290 0 Ignition 1 iButton 0 U8 Enable Disable 291 0 Disable 1 Enable 0 1 U8 Activation Timeout in second...

Page 54: ...Trip Start Stop Detection 0 disable 1 enable 280 0 1 1 U8 Start Speed 281 0 255 5 U8 Ignition Off Timeout 282 0 65536 60 U16 Trip Continuous Distance Counting 0 not 1 continuous 283 0 1 0 U8 CAN Type...

Page 55: ...e Data Link Timeout 109 5 259200 time in seconds 5 Ringtone Parameter 110 1 10 number corresponding ringtone 1 Accelerometer Filter Start Value 112 1 9999 time in seconds 1 Accelerometer Filter Stop V...

Page 56: ...IM1 GPRS PASS 167 all char range SIM2 GPRS APN 168 all char range SIM2 GPRS USER 169 all char range SIM2 GPRS PASS 170 all char range 6 4 Read Records FM5500 supports two records sizes mode 64 Bytes a...

Page 57: ...eports based on imported data More details on how to use TAVL application please refer to TAVL3 application user manual v1 4 documentation or its latest versions Note that FM55500 can have memory full...

Page 58: ...ze Settings When switching from 64 Byte Length Records mode to 256 Byte Length Records mode the IO elements are not disabled but the memory is fully formatted and all the records in memory will be los...

Page 59: ...n GSM operator code mostly used for roaming applications or by Profile switch depending on I O event on I O value changing Profile 3 is default profile for FM5500 It is always loaded on the very first...

Page 60: ...ile 2 operators list This code is entered there so FM5500 switches to profile 2 If there are no operator codes entered in all profiles after operator search task FM5500 will check all 3 profiles and w...

Page 61: ...enter exit on both hysteresis predefined by High and Low level thresholds SW21 SW22 SW23 SW24 stands for Switch to profile No X After an event happens FM5500 switches to a defined profile Using profi...

Page 62: ...ile Y Profile X Figure 45 Digital input event criteria Example 1 Configuration of Profile1 to switch to Profile2 on DIN1 value change from 0 to 1 Figure 46 Switch to profile on event 1 Example 2 Confi...

Page 63: ...mode is used FM5500 will work normally but there will be more switching activities In addition APN settings in Global parameters should be entered for SIM 1 and SIM 2 to avoid not sending records ove...

Page 64: ...s list At first it tries to connect to SIM 1 Home Operator if operator is unreachable the device switches to SIM 2 slot and tries to connect to SIM 2 Home Operator Figure 50 Home network setting When...

Page 65: ...list for available operators If the connection is lost FM5500 will return to Home profile and try to connect to Home operators as it has higher priority FM5500 checks a possibility to connect to Home...

Page 66: ...Operator list Unknown Operator Unknown Operator profile Figure 53 has the fourth priority after the Home network after SIM 1 Roaming operators list and after SIM 2 Roaming operators list The user cann...

Page 67: ...67 Figure 53 Unknown Operator List...

Page 68: ...68 Dual SIM algorithm Two SIM cards use algorithm is shown in the diagram Figure 54 Figure 54 Dual SIM connection algorithm...

Page 69: ...from operator s list or the operators list is empty then the FM5500 connects to Unknown operator In all cases when a timeout has appeared the operator search procedure is done If better home operator...

Page 70: ...aved record If differences are greater than configured value a record is generated Checking sequence first angle is checked then distance and lastly time differences Figure 55 GPS acquisition configur...

Page 71: ...itable for urban territories Note that record generation by angle is performed if vehicle is moving at least 6 km h Min angle Figure 58 Angle based tracking 9 2 I O data acquisition Data also can be a...

Page 72: ...Saved Time t High Level Low Level 4 Monitoring Figure 62 Monitoring Speed Km h 100 20 0 Event Generated Record Saved Time t High Level Low Level 5 Hysterisis Figure 63 Event on Hysteresis Event on Zon...

Page 73: ...igh USB cable is connected HIGH or PANIC priority eventual record is detected While being in sleep mode FM5500 cannot save periodical or eventual records send data to server 11 DEEP SLEEP MODE While i...

Page 74: ...enarios Eco Driving Green Driving and or Over Speeding Digital Output No 2 is used by scenarios Authorized Driving or Immobilizer 12 1 Eco Green Driving Scenario ECO driving Green driving Scenarios He...

Page 75: ...functionality will operate correctly only if device is mounted into the vehicle in a proper position Eco Driving functionality operation is based on accelerometer It is important to mount FM5500 devic...

Page 76: ...e allowed But it should be as straight as possible Deviations of maximum 15o are allowed Figure 65 1 5 0 1 5 0 Figure 65 MAX deviation from horizontal plane of FM5500 mounting 20 max 20 max Figure 66...

Page 77: ...ivity Increasing sensitivity means that more acceleration can will be detected on the same period of time Response time decreases Braking Detection Sensitivity Lower the value to increase sensitivity...

Page 78: ...of 3 55 m s2 detected Record with value 3 55 10 35 5 36 will be saved ant sent to server 12 2 Overspeeding Scenario Overspeeding Helps to prevent from exceeding fixed speed and inspects driver if need...

Page 79: ...er Scenario 12 4 Authorized Driving Scenario Authorized Driving Gives ability to use vehicle only for 50 specific iButton owners specified in iButton list DOUT2 is controlled by scenario for user need...

Page 80: ...Settings Mode LLS Note On COM1 Level will be with ID 201 Temperature will be with ID 202 On COM2 Level will be with ID 203 Temperature will be with ID 204 On Valid data Receive Status LED will blink...

Page 81: ...w to use From Terminal need send command WT W your text here From Hercules server Send DO DAT you text here in special packet Notes DO DAT command prints only to COM2 in addition these commands were a...

Page 82: ...Garmin 3 External Devices COM2 Settings Parity None Ping Filter Enable Parameter 0 DISABLED Ping packet will not blocked 1 ENABLED Ping packet will be blocked Unicode Support Packet Enable Parameter...

Page 83: ...ll be ignored COM TCP Link Mode In this mode link with external device using text messages can be established Any string of data coming to COM will be routed to server if link is currently active Firs...

Page 84: ...COM2 Settings Timeout any setting x10 msec How much time to wait before detecting end of packet 5 External Devices COM2 Settings Parity any setting 6 External Devices COM2 Settings Prifix1 any setting...

Page 85: ...readops Emergency gsm operator readout from active profile 1 2 3 1 operators 1 20 2 operators 21 40 3 operators 41 50 Yes getnmeainfo Nmea error debug sms Yes ggps Google Map Link information Yes getc...

Page 86: ...aninfo Get LV CAN info by SMS Yes 13 1 getstatus Table 29 getstatus Response details Description Data Link Indicate module connection to server at the moment 0 Not connected 1 connected GPRS Indicate...

Page 87: ...of current available allowed operators Answer Example GSM OP LIST 0 24602 13 4 readops Table 32 readops Response details Description LIST Returns acknowledgment of operators in active profile configu...

Page 88: ...GPS data Sat Count of currently available satellites Lat Latitude Last good Latitude Long Longitude Last good Longitude Alt Altitude m Speed Ground speed km h Dir Ground direction degrees Date Curren...

Page 89: ...e Answer Example DI1 0 DI2 0 DI3 0 DI4 0 AI1 0 AI2 0 AI3 0 AI4 0 DO1 0 DO2 0 DO3 0 DO4 0 13 14 getinfo Table 39 getinfo Response details Description INI Device Initialization Time RTC RTC Time RST Res...

Page 90: ...e OUT1 OUT3 and OUT4 to low level Ans example DOUTS are set to 0010 TMOs are 0 0 5 0 Out1 Scenario Enabled Out2 Scenario Disabled 13 18 getparam Read parameter value ID consists of 4 digits first digi...

Page 91: ...lush Response details Description FLUSH SMS Accepted FLUSH SMS Accepted records found on FLASH Number of records found on FLASH Minimum Records to Send Number of minimum saved records to send GPRS Ena...

Page 92: ...minfo Table 45 braminfo Response details Description Boot Bootloader parameter Uptime Device uptime RST Device reset counter IWDF_RST Independent watchdog reset counter BadRec Bad record counter AD Au...

Page 93: ...Switch S2S SIM2 Status S2I SIM2 IMSI S2H SIM2 HOME Operator S2R SIM2 Roaming Operator SIM_STATUS S1S S2S description 0 STATUS_OK modem ready 1 S_SIM_PIN_ACCEPTED 2 S_SIM_PIN_NOT_ACCEPTED 3 STATUS_NO_S...

Page 94: ...SAE J1939 is the vehicle bus standard used for communication and diagnostics among vehicle components Based on the same architecture FMS protocol dedicated to telematics systems is available It has c...

Page 95: ...speeds 50 kbps 100 kbps 125 kbps 250 kbps 500 kbps Auto Baud rate detection Filtering messages StId ExtId according to configuration Using mask filters required bytes Different CAN configurations 14...

Page 96: ...d bytes only selected bytes are sent to server Figure 75 CAN message filter configuration 14 3 Example A sample CAN message has the following structure X18FEE9018FFFFFFFF23840300 where essential parts...

Page 97: ...y connecting to special PSM module which may or may not be included in the truck or ground module of the vehicle For CAN signal to be available parameter 520 must be enabled in kommunikationsschnittst...

Page 98: ...Data Byte 7 Data Byte 8 Byte No Not used for FMS Standard Not used for FMS Standard Not used for FMS Standard Not used for FMS Standard Total fuel used 0 5 L Bit gain 0 L offset 5 2 5 66 SPN 250 Total...

Page 99: ...rator has them listed starting with MSB After message is filtered it is attached to the data packet and sent to the server Values are returned in HEX 00 03 84 23 HEX 230435 DEC Notice that data resolu...

Page 100: ...tion of columns Category shows CAN message Parameter shows configurable parameter name Value shows scanned value of parameter Send data to server allows to choose the type of data when it s generated...

Page 101: ...eter value becomes between High and Low values o Event on both record is generated when parameter value crosses High or Low values Low allows to choose low value for Data acquisition High allows to ch...

Page 102: ...e all data monitoring push Select none button Note CAN monitoring is FM5500 configurator function it does not enable data sending to server In order to configure data sending to server refer to Config...

Page 103: ...Engine total fuel used 4 86 0 2105540607 5 Liters 65276 Dash Display 9 9 fuel level 1 X 4 87 1 102 61444 Electronic Engine Controller 1 10 10 engine speed X 4 88 0 8031 875 rpm 65258 Vehicle Weight 1...

Page 104: ...in bef 9h 4 9h reached 5 15min bef 16h 6 16h reached 7 Error 8 not available 38 24 Driver 2 time rel states 1 119 0 Normal 1 15min bef 4 5h 2 4 5h reached 3 15min bef 9h 4 9h reached 5 15min bef 16h 6...

Page 105: ...ke foot pedal is controlling the vehicles service brake total vehicle braking application not park brakes It is necessary for safe drivetrain behavior that the switch activates before the physical bra...

Page 106: ...ry for a safe drivetrain behavior that the clutch switch is set before the clutch is opened cruise control function 00 Clutch pedal released 01 Clutch pedal pressed 10 Error 11 Not available Data Leng...

Page 107: ...governor Set 00101b Used to indicate that the PTO governor is establishing current speed as the operating speed captured value Decelerate Coast 00110b Used to indicate that the PTO governor is in the...

Page 108: ...emory two set state is active Data Length 5 bits Resolution 32 states 5 bit 0 offset Data Range 0 to 31 Operational Range same as data range Type Status Supporting information PGN 65265 Note Firmware...

Page 109: ...ent to server is already adjusted with bitgain Since data is sent as U32 value after floating point is ignored Fuel level 1 Ratio of volume of fuel to the total volume of fuel storage container When F...

Page 110: ...rting information PGN 65253 Note Value sent to server is already adjusted with bitgain Since data as sent as U32 value after floating point is ignored Vehicle identification number Vehicle Identificat...

Page 111: ...this FMS standard Diagnostics Supported feature is supported by the FMS Gateway the FMS Gateway will support the requests for diagnostics information from the FMS device onto the vehicle network and...

Page 112: ...usted with bitgain Service distance The distance which can be traveled by the vehicle before the next service inspection is required A negative distance is transmitted if the service inspection has be...

Page 113: ...e overspeed Indicates whether the vehicle is exceeding the legal speed limit set in the tachograph 00 No overspeed 01 Overspeed 10 Error 11 Not available Data Length 2 bits Resolution 4 states 2 bit 0...

Page 114: ...tion PGN 65132 Note Firmware captures all values 0x00 0x03 0x00 0x03 range is valid for all FM5300 FW and FM5302 until and including 01 02 10 Rev 00 Since FM5302 01 02 10 Rev 01 only these values are...

Page 115: ...ge same as data range Type Status Supporting information PGN 65132 Note Firmware captures all values 0x00 0x03 System event Indicates that a tachograph event has occurred This may include power supply...

Page 116: ...o s complement The value sent to the server has already been adjusted for the bitgain and offset Ambient air temperature Temperature of air surrounding vehicle Data Length 2 bytes Resolution 0 03125 d...

Page 117: ...fter floating point is discarded Data limit becomes 0 125 This could have been 1 B IO element but it is 4 B Firmware sends value which is already adjusted with bitgain At least one PTO engaged Indicat...

Page 118: ...ctronic Engine Controller 2 05 Accelerator pedal position 1 X 06 Engine Percent Load At Current Speed X 65257 Fuel Consumption 07 Engine total fuel used 65276 Dash Display 08 fuel level 1 X 61444 Elec...

Page 119: ...quid 52 High resolution engine total fuel used AutoCAN element parameters AutoCAN Element parameter ID Description Parameter Value XXXX0 Sets Send Data to Server parameter 0 Disable 1 On Low Priority...

Page 120: ...lock diagram FM1100 shares the same USB port for connecting adapter and configuring device with PC LV CAN200 Technical characteristics PARAMETER VALUE Supply voltage 9 to 50V Power supply current Aver...

Page 121: ...se the SWITCH Then LED starts blinking and counting first digit of program number one blink means digit 1 two blink digit 2 etc To stop counter push SWITCH Release the SWITCH then LED starts blinking...

Page 122: ...e Pin 4 Negative Pins 9 10 connection is optional it depends on exact car model For exact pinout see sticker on Light Vehicles Can adapter Figure 86 LV CAN200 Adapter connection cable pinout Attention...

Page 123: ...ing Save button To configure CAN data 1 In car connect LV CAN200 to CAN bus and to the FM5500 device Figure 87 wait 10 seconds Note that car engine must be started 2 Disconnect LV CAN200 from FM5500 a...

Page 124: ...n for that was CAN element change When High priority is selected module makes additional record with high priority flag and sends event packet immediately to the server by GPRS Panic priority triggers...

Page 125: ...aram IO ID Value range 65265 Cruise Control Vehicle Speed 0 Vehicle Speed 1 81 0 250 km h 61443 Electronic Engine Controller 2 1 Accelerator Pedal Position 4 82 0 100 65257 Fuel Consumption 2 Total Fu...

Page 126: ...rameters and allowed min max values Parameter ID LV CAN200 IO Element Minimum low level value Maximum high level value X00Z Speed 0 250 X01Z Accelerator pedal position 0 100 X02Z Total fuel used 0 999...

Page 127: ...884443332221110 15 9 References 1 Light Vehicles Can adapter LV CAN200 Supported cars 2 Cars mounting scheme 16 RS485 INTERFACE RS485 supports only Half Duplex communication It means that at the same...

Page 128: ...re described below are setting in the configuration window RS485 Receive Silent Mode Figure 91 Silent Mode RS485 Works in receive mode Support debug and testing commands When command is received answe...

Page 129: ...nsmit mode for 2 seconds RS485 Receive LLS Mode Figure 93 LLS Mode The mode supports up to two LLS Baud rate must be 19200 LLS have receiver id Smaller ID will get ID 201 and ID 202 Bigger ID will get...

Page 130: ...pond to commands RS485 Self Test Mode Figure 96 Self Test Mode Both transmitter and receiver are active Transmitted info will be echoed back 16 2 RS485 interface Port connection diagram are shown on t...

Page 131: ...d to FM5500 the device creates a record with the data that the RFID reader has read and can be sent to a server with all other information RFID ID is activated like an I O parameter Figure 98 Figure 9...

Page 132: ...41519 The chosen mode has to correspond to the RFID reader s mode What type of RFID is sent to FM5500 depends on the reader For more information about RFID ID s and devices please contact to your loca...

Page 133: ...Allows text messages sent to device to be displayed in inbox on unit Garmin can provide confirmation that message was read Garmin can also provide a yes no box below the text of the message to enable...

Page 134: ...arrival feature is activated Data Deletion Protocol Dispatch office has the ability to wipe clean the data on the Garmin PND Clean up messages in inbox remove stops Enhanced protocols Canned Response...

Page 135: ...nation and distance in meters from current object location to currently active destination 18 6 Connection and pinout Figure 101 RJ45 Pinouts In order to connect Garmin PND to FM5500 Garmin mode has t...

Page 136: ...nts of standard factory grade DIESEL OIL and PURE GASOLINE BENZINE carbon fuels The LLS sensor liquid level sensors are strictly prohibited to use in any liquids which are not the factory grade carbon...

Page 137: ...485 Line A A2 Blue white EIA 485 Line B 19 3 Connecting LLS to FM5500 In order to use LLS fuel counter the 01 00 01 Firmware version or later is needed which can be obtained from Teltonika or a repres...

Page 138: ...nsors connection via RS232 scheme RJ 45 male plug to Port 1 and one fuel sensor connection via RS232 to Port 1 is shown on Figure 103 Figure 103 FM5500 LLS two fuel sensor connection via RS232 scheme...

Page 139: ...hen in case utilization of just one interface wires of the unused interface will not be utilized It s necessary to insulate them carefully on LLS side for example with hot shrink tubing for avoiding a...

Page 140: ...late the values using polynomial calculation When LLS sensor is connected the same is applied but it is possible to enter the polynomials into the configuration of FM5500 and it sends the sum of both...

Page 141: ...ld be poured and the next value written down and so on This should be done till the tank is full Then the calculation of polynomials has to be made Here is an example of how to do this with the values...

Page 142: ...chart creation Then right click on the chart line and select Add Trendline Figure 109 Figure 109 Adding a trendline Select a polynomial type of 5th order trendline Also select Display equation on cha...

Page 143: ...lecting polynomial order A new line appears alongside the created one as well as a formula for that new line Figure 111 Figure 111 Calculated polynomial line and calculation formula Final view of the...

Page 144: ...nomials can be written in the configuration of the device To do this go to global settings and choose both ports to work in LLS mode Figure 112 Also repeat the steps for the second LLS sensor if it is...

Page 145: ...al setup After the configuration is saved successfully FM5500 is ready to send measured fuel level For additional information about LLS sensors their configuration and connectivity to FM5500 please co...

Page 146: ...ference Figure 114 Figure 114 Sensors connection Five LLS sensors can be connected using 01 03 07 or above LLS device connection 1 Configure FM55 Untit 2 Remove Power from FM 3 Remove Power from LLS 4...

Page 147: ...iguration 4 After Power ON procedure with connected sensors Press Load 5 Ensure that all sensors are visible 6 Press save to save order into device 7 In Profile1 Profile2 Profile3 Profile4 enable requ...

Page 148: ...LLS1 and LLS2 Figure 119 I O element configuration 6 Lower sensor adress will have ID 201 other ID 203 c One or two sensors Level Calucualtion using Polynoms Values 1 Under RS485 settings select LLS M...

Page 149: ...e in liters depends on calibration on ID 201 7 In Profile1 Profile2 Profile3 Profile4 enable required IO fields for LLS1 and LLS2 Figure 122 I O element configuration Note ID 203 will hold raw LLS2 va...

Page 150: ...tion GET DATAORDER Get info about records sorting parameter SET DATAORDERX Y Set records sorting parameter X profile Y value 0 1 GET RECTO Get info about records refresh timeout parameter SET RECTO X...

Page 151: ...ain profile X profile Y MinRecords value GET IBTNX Get iButton value from the configuration of a certain profile X profile SET IBTNX Y Z Set iButton value to the configuration of a certain profile X p...

Page 152: ...ew Parameter Value flush Initiates all data sending to specified target server 1 IMEI 2 APN 3 LOGIN 4 PASS 5 IP 6 PORT 7 MODE 0 TCP 1 UDP sn x x 0 1 Enable disable static navigation banlist Banlist in...

Page 153: ...solutions when operating as unexpected Contact our sales manager to get Terminal After launching it choose baud rate 115200 and hardware control none Click on Start Log button and save a new file Then...

Page 154: ...14 09 29 1 13 Added 5 RS485 LLS sensors configuration description 14 2015 03 02 1 14 External battery information added continuous odometer start value added 15 2015 08 28 1 15 RS 485 LLS connection s...

Page 155: ...155 24 2016 08 22 2 08 Corrected Virtual COM Port driver download link...

Reviews: