background image

Preliminary Users Manual, Telex SAFE-1000 System. 

 
Telex Model SAFE-1000 Wireless Microphone Receiver. 
Telex Model SAFE-WT Wireless Beltpack Transmitter. 
Telex Model SAFE-HT Wireless Handheld Transmitter. 
 
The components above form the Telex “SAFE-1000” Professional Grade 
DIGITAL Wireless Microphone System. The system is designed to be used 
in professional installations where Sound Quality and Reliability are of 
prime importance. Auto-set features and simplicity of operation are assured 
along with flexibility for varying venues. These features save valuable 
installation time at the outset and in the future to help prevent “recalls”. The 
features of the “SAFE-1000” system such as user programmable frequencies 
or pre-programmed frequency sets mean that other users such as Rental 
Houses with itenerant operations will spend the least amount of time feasible 
during set-up. 
 
Features: 
 
Receiver…. 

• 

In-Line Receiver Power Supply saves terminal strip occupation. 

• 

International Power Supplies and cordsets off the shelf. 

• 

Phase Locked Frequencies for stable Operation. 

• 

950 Radio Channels, user programmable or factory installed. 

• 

LCD Displays for ease of viewing. 

• 

Patented Phase Diversity System. 

• 

Control port for relay closure.  

• 

Adjustable Line Level ¼ inch output jack. 

• 

Fixed Microphone Level XLR output jack. 

• 

Front Panel Power ON/OFF Switch. 

• 

Quadruple Tuned Ceramic Resonator front end for superior 
interference rejection. 

• 

SAW Filter 1

st

 I.F for out of band rejection. 

• 

Triple ceramic filters in 2

nd

 I.F for adjacent channel rejection.. 

• 

Double Tuned Quadrature circuit for low audio distortion. 

• 

Permanent Flash Memory for frequency/system storage. 

 
 
 

Summary of Contents for SAFE-1000

Page 1: ... pre programmed frequency sets mean that other users such as Rental Houses with itenerant operations will spend the least amount of time feasible during set up Features Receiver In Line Receiver Power Supply saves terminal strip occupation International Power Supplies and cordsets off the shelf Phase Locked Frequencies for stable Operation 950 Radio Channels user programmable or factory installed ...

Page 2: ...ain vs power system High Low power switch for range cut boost or intermod reduction Patented Internal Dipole antenna eliminates wires or rubber duck antennas Removable Heads allow personal selection of available heads Specially shaped Handle with softpaint for comfort and low handling noise 9 Volt Alkaline rattle proof battery area Low Profile Audio Mute and Power Switch LCD Display for ease of vi...

Page 3: ... Wireless Microphone Receiver The Telex Model SAFE 1000 Receiver is a 950 Channel frequency selectable full diversity system operating within the frequency range of 520 0 to 608 and 614 to 746 0 MHz on specific pre set bands of frequencies with designated systems for UHF Television Channels distance away from the area where the FMR 1000 is to be used Channel spacing has been computer calculated an...

Page 4: ...io Frequency Signal Noise Ratio 100 db Temperature Range 18 deg C to 54 deg C SAFE 1000 Receiver Sensitivity 0 8 uV for 12 db SINAD Nominal Image Rejection 60 db minimum Spurious Rejection 60 db minimum Selectivity 230 KHz at 6 db points Modulation Acceptance 40 KHz nominal deviation Squelch Type Tone with Amplitude Backup Squelch Adjustment Range 0 to 30 uV Typical Squelch Quieting 100 db Audio O...

Page 5: ...ulation Limiter Limiter Compressor Audio Input 7 75 mV for 40 KHz Deviation 77 5 mV for instruments Power 9 0 VDC Alkaline SAFE HT Transmitter RF Power Output 5 mW Low 50 mW High typical Terminated Antenna Internal Wave Dipole Modulation Type NFSK 200f1E FM 40 KHz Deviation Modulation Limiter Limiter Compressor Audio Input 7 75 mV for 40 KHz Deviation Power 9 0 VDC Alkaline ...

Page 6: ...ns will occur unless the SET Key is pressed SET This key is used to initiate any change to the screen currently being viewed Flashing blinking characters will be seen after the SET Key is pressed The flashing characters can be changed by use of the Arrow Keys or accepted as is by using the SET key Use the MENU Key to exit the current screen Exiting a screen with the MENU Key terminates any flashin...

Page 7: ...e in the audio system 8 Press the Menu Button one more time The first operating screen appears again 9 Press the Power switch on the receiver front panel to turn the unit off 10 Plug the mixer or other audio system into the receiver XLR Microphone Level Connector or into the inch Line Level Jack Set the Line Level Control near the inch jack to about 50 of rotation 11 Insure that the audio mixer or...

Page 8: ...w Battery Light near the display should come on for a few seconds The display will also come on briefly displaying two screens of software versions 7 The screen will stop at the GP Group and CH Channel screen If the Group and Channel agree with the receiver Group and Channel proceed to step 8 If the Group and Channel do not agree with the receiver go to step 10 8 Monitor the SAFE 1000 Receiver 1st...

Page 9: ... check the set up Quick set up BeltPack Transmitter 1 Insure that the Power switch in Transmitter is in the OFF position 2 Install a fresh Alkaline Battery into the transmitter 3 Insure that the Microphone Gain Control is set at about 50 of rotation 4 Check the position of the Transmit Power Switch If this is a single microphone System place the switch in the High Power position If this is a multi...

Page 10: ...nge them for any reason proceed with this step The transmitter Group Channel screen should be displayed now If not press the Menu Key one touch at a time until the Group Channel is displayed Press the SET Key one time The CH number will start flashing Use the UP arrow switch to increase the channel number or the Down arrow to decrease the channel number Once you have the desired channel selected p...

Reviews: