background image

EXCITE, ENGAGING CARDIO

SYNCHRO

User manual

Summary of Contents for SYNCHRO

Page 1: ...EXCITE ENGAGING CARDIO SYNCHRO User manual...

Page 2: ...rnings 12 Place of usage 14 Moving the equipment 15 Levelling 16 Electrical connection mains powered version 17 Connection to another device 19 Routine maintenance 21 Changing the fuses mains powered...

Page 3: ...or injury to person take the following precautions The equipment should never be left unattended when plugged in Unplug from outlet when not in use before cleaning it and before putting on or taking o...

Page 4: ...Never drop or insert any object into any opening To disconnect turn all controls to the off position then remove plug from outlet SAVE THESE INSTRUCTIONS Warnings Do not connect a device with load ex...

Page 5: ...se clothing and shoes during a workout no loose clothing Tie long hair back Keep garments or towels away from moving parts During use people must remain at a safe distance Do not use the equipment in...

Page 6: ...installation debris resulting from any construction activities in the product s environment rust or corrosion as a result of the product s location alterations or modifications without Technogym s wr...

Page 7: ...the User manual F Serial number and date of manufacture G Product model The Synchro is a commercial device designed for use in residential and professionalenvironments ItisaclassSAdevice pursuanttoISO...

Page 8: ...Fixed handgrips C they are gripped when working out only with legs Hand sensor D the metal plate sensors permit constant heart rate monitoring Fast Track Control E they allow users to change the effor...

Page 9: ...pm 500 W at 120 spm Minimum braking power 20 W at 60 spm 45 W at 60 spm Weight of equipment 148 kg 326 lb 150 kg 330 lb Maximum user weight 180 kg 396 lb 180 kg 396 lb User heigh for which performance...

Page 10: ...Synchro Excite 10 752 mm 30 2042 mm 80 1609 mm 63 Technical data...

Page 11: ...al C Warranty certificate D CEE Power Supply cable with SH socket mains powered version E Cloth for cleaning F Two replacement fuses 2 x 3 15A F mains powered version The charger comes with the batter...

Page 12: ...to the inside of the equipment In the mains powered version B Main switch turns the equipment s power on and off C Fuses theyprotecttheequipment selectricalparts Whenthecurrentreachesanexcessivevalue...

Page 13: ...e information about possible risks and hazards D The label affixed to the frame under the control panel states the electrical specifications E The label which can be affixed close to the main switch s...

Page 14: ...the floor is flat stable and vibration free and strong enough to bear the weight of the equipment plus user Do not expose the equipment to direct sunlight Do not use outdoors Do not leave the equipme...

Page 15: ...evers or the control panel as hand holds The equipment has two fixed rear wheels To move the equipment lift it up slightly as shown in the illustration and push it forwards and backwards Given the wei...

Page 16: ...A A Levelling Use the two front feet and the central foot to level the equipment loosen the lock nut B screw the front feet A in or out until the frame is in a stable position tighten up the lock nut...

Page 17: ...ifications on the label applied to the frame under the control panel Plug the power cable first into the equipment socket and then into the wall socket Warnings The wall socket must be located in a pl...

Page 18: ...ric shock The product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded i...

Page 19: ...es conforming to the CSAFE protocol only for setting and maintenance functions Additional devices connected to the digital interface must conform to the respective IEC standards that is IEC 60950 for...

Page 20: ...ment and to the wall socket Use an RF coaxial cable for the connection with an F type of connector for the equipment The wall socket of the aerial cable must be positioned so that the plug can be easi...

Page 21: ...quipment completely turn the equipment off by switching the switch to the 0 position mains powered version unplug the equipment power cable from the wall socket mains powered version clean the externa...

Page 22: ...routine maintenance adjustment and lubrication jobs must be performed by the Technogym Technical Support Service Before starting any job turn the equipment off by switching the switch to the 0 positi...

Page 23: ...r cable plug from the wall socket Remove the fuse holder to the right of the switch by pushing the lever Replace the blown fuse with a new one as supplied 3 15A F Fit the fuse holder back into its hou...

Page 24: ...t remains switched on If when you stop moving the platforms the control panel switches off without warning the battery will have to be recharged Charger electrical specifications Input 100 240 Vac 0 8...

Page 25: ...ems with the power supply cable mains powered version Check the connection Burnt out fuses mains powered version To replace the blown fuse with a spare contact Technogym Technical Support Service The...

Page 26: ...interference minimum distance between two units 80 cm Strong interference sources nearby Find the interference source e g an electrical domestic appliance and move it away or move the equipment Worn h...

Page 27: ...the Technogym Technical Support Service you must give the following information model date of purchase serial number precise description of the problem Warning Work on the equipment by persons unauth...

Page 28: ...se is expected you are advised to store the equipment in the following way in a clean dry place with a dust cover at a room temperature between 10 C and 70 C and relative humidity between 20 and 90 Fo...

Page 29: ...ppropriate handling recovery and recycling Unauthorised dumping or disposal of electrical and electronic equipment or improper use of the same can cause serious damage to the environment and human hea...

Page 30: ...Synchro Excite 30 B A C D E Disposal Undo the screws A and remove the cover B Undo the screws C and remove the cover D Remove the cover E...

Page 31: ...Synchro Excite 31 H G F L Disposal Disconnect the cable on the red terminal F first then the cable on the black terminal G Cut the strap H Remove the battery L...

Page 32: ...tion To turn the battery powered version of the equipment on start moving After a quick system check reset the equipment is ready for use In this mode the following functions are enabled calculation o...

Page 33: ...hen in standby Iftheequipmentisn tgoingtobeusedforalongtime aswellasturningitoffyoushouldalso pull the plug out of the wall socket Warning The switch is for turning the equipment on and off but does n...

Page 34: ...mitter Polar T31 There must be no more than one transmitter in the reception range otherwise the receiver may receive different signals at the same time and give incorrect heart readings If there are...

Page 35: ...energy source When doing aerobic exercise at a heart rate of 70 to 90 the cardiocirculatory component prevails Forexample ifsomeoneaged30wantstoburnofffat theheartrateduring exerciseshouldbekepttobet...

Page 36: ...ged in competitive sport The sole function of the heart rate monitor is to display the heart rate during exercise and cannot be used for medical cardiac diagnoses of any kind The heart rate shown on t...

Page 37: ...that you get used to the movement without leaning forward and assuming unnatural positions Once you become more confident gradually increase the effort level Constantly check your position head held h...

Page 38: ...Synchro_Excite_en AA 0SM00977...

Reviews: