background image

High Pressure Washer 

Operating and Maintenance Manual 

 

CONTENTS 

A.  GENERAL INFORMATION 

B.  SPECIFICATION 

C.  PREPARATION BEFORE OPERATION 

D.  SAFETY INSTURCTIONS 

E.  OPERATION INSTRUCTIONS 

F.  TROUBLESHOOTING 

G.  PERIODIC INSPECTION & MAINTENANCE 

H.  WARRANTY 

 

 

 

 

 

 

 

Summary of Contents for TAR 12/120 M1

Page 1: ... Operating and Maintenance Manual CONTENTS A GENERAL INFORMATION B SPECIFICATION C PREPARATION BEFORE OPERATION D SAFETY INSTURCTIONS E OPERATION INSTRUCTIONS F TROUBLESHOOTING G PERIODIC INSPECTION MAINTENANCE H WARRANTY ...

Page 2: ...chnician must report any fault to the supplier The machine is meant for specific applications Do not modify and or use it for applications other than the specified ones Instructions drawings tables and all the contents of this document are confidential technical documentation and are the exclusive property of TANONG Precision Technology Co Ltd No information may be released to third parties withou...

Page 3: ...se possible death or sustain serious injury It indicates that an unfair use may highly cause possible death or sustain serious injury It indicates that an unfair use may highly wound the user and or damage the product also is possible to bring out an unpredictable event ...

Page 4: ... M3 12 L min 120 bar 3HP three phase 58Kg 1 TAR 12 180 M1 12 L min 180 bar 5HP single phase 67Kg 1 TAR 12 180 M3 12 L min 180 bar 5HP three phase 58Kg 1 TAR 17 120 M1 17 L min 120 bar 5HP single phase 67Kg 1 TAR 17 120 M3 17 L min 120 bar 5HP three phase 67Kg 1 TAR 15 200 M3 15 L min 200 bar 7 5 HP three phase TAR 15 250 M3 15 L min 250 bar 10 HP three phase TAR 17 230 M3 17 L min 230 bar 10HP thr...

Page 5: ...ensor system would initiate the protective mechanism for motors When red indicating light is on it means the cleaner is energized normally When it blinks on the other hand it means the pump runs idle suck in air without water and the automatic mode is locked in order to prevent running abnormally When yellow indicating light is on it means the cleaner has run for 300 hours and it is needed to chan...

Page 6: ...s blink it means water leakage has occurred for 3 4 times and the automatic mode would be locked and stop spraying water If you want to keep using automatic mode turn the knob switch to OFF or MANUAL MODE Indicators of malfunction or water leakage ...

Page 7: ... of high pressure pump and the water inlet fitting of spray gun c Please use open end wrench to tighten filter onto water inlet end of pump Check filter sieve has been installed properly before connecting hose with the coupling of filter 3 Connected to water supply It is recommended to use 3 4 inch or the high pressure hose with minimum section diameter of 14 mm The inlet water amount should not b...

Page 8: ...ould accord with the standard of CEI364 including the requisites of earth wire fuse and residual current circuit breaker with the sensitivity less than 30mA The voltage difference of the power supply should not exceed 5 of the rated voltage Please ensure that power cable should not be longer than 10m with the minimum section of 3 5mm2 If you need longer cable please contact the specialized Technic...

Page 9: ...pting any cleaning or maintenance Fail to do so may cause electric shock 4 If any important part gets damaged stop using this machine immediately 5 The cleaner or electrified circuit including every installation cable and electric socket should not be spilled with water Keep the plug and wire dry and clean and do not touch it with wet hands Carefully remove the plug from the electric socket and do...

Page 10: ...er gun please hold tight the gun because of strong recoil Do not spray at people animals electric instrument on using of this machine When you do not use it please turn off the safety switch on the gun If the temperature is possible to drop to less than 0 oC in winter the remaining water in the pump cylinder is likely to freeze Do not use this cleaner at this time If you want to use it please add ...

Page 11: ...t If you want to continue to apply automatic mode please change to manual mode and undergo troubleshooting procedure before you turn to automatic mode c This cleaner is installed with circuit breaker of overload switch d When the yellow light of the indicator for 300 hours blinks which only provides the information of changing oil The automatic mode would command the cleaner not to work unless you...

Page 12: ...w Rate 21 L min Thread Type NPT 1 4 External Diameter 36 mm Full Length 100 mm Weight 130 g b Matching table of pressure bar and flow rate L min of different types of nozzles Nozzle Specification Operational Pressure Unit Bar 80 100 120 140 170 200 220 035 7 2 8 0 8 7 9 4 10 4 11 5 11 9 045 9 2 10 3 11 3 12 1 13 4 14 5 15 2 055 11 3 12 5 13 8 14 8 16 4 17 7 18 5 Nozzle Cleaning In order to avoid p...

Page 13: ... procedures please turn the switch to OFF state and break the power supply Remove the wire from the power and roll up carefully avoiding to bend it Remove the high pressure hose from the cleaner and roll up carefully avoiding to bend it Remove the spray gun and store it appropriately After the motor cools down to room temperature clean the water logging on the surface of this machine and put it in...

Page 14: ...standby Valve could not work normally Pipe or gun could not fit closely Send to repair Change gasket The high pressure cleaner fails to reach maximum pressure The bolt of pressure spring of unloader valve has not been fastened Nozzle is on low pressure state The nozzle is worn The internal parts of unloader valve and seals are worn out Plunger seal gasket is worn out Fasten the pressure spring set...

Page 15: ...al mode to let the air comes out Check whether the water supply feeds water or not Inflow of water into pump crankcase Water seal or oil seal is worn out Send to repair Both yellow and red light blink at the same time Abnormal water leakage for 3 4 times Turn the knob switch to STOP or Manual mode and then it could go back to Automatic mode and spray water normally ...

Page 16: ...commendation 1 Routine Maintenance Maintenance Schedule Items Job Before operation Water inlet filter Check if there is blockage or dirt Pump Check the oil quantity Every 50hrs Motor and pump Change oil Limited for 1st time use Check if the pump and motor has been fixed firmly Check if electric control function is normal Pipe and power supply Check if spray pipe and wire has been fixed firmly Ever...

Page 17: ...3 Exploded view Drawing of AR RKA High Pressure Pump Accessories 4 Parts list of AR RKA high pressure pump ...

Page 18: ...d installer Use of non original or not specified parts for the cleaner The damages caused by natural disasters faulty usages or consumable purposes Manufacturer shall not be liable for any further loss damages or expenses including incidental or consequential damages directly or indirectly arising from the sale or use of this product This warranty does not cover repair or replacement of any item t...

Reviews: