background image

 

 

WEBS-PA-2IP / WEBS-PA-2IP-12 Area Paging Unit  

Installation Instructions 

 

Copyright 2012 Talk-A-Phone Co.  All rights reserved. 

 

Rev. 8/27/12

 

 

Talk-A-Phone Co. 

• 7530 North Natchez Avenue • Niles, Illinois 60714-3804 

Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com 

Talk-A-Phone  and WEBS are registered trademarks of Talk-A-Phone Co. 

 
 
 

 
 

I.  Introduction 

 

Model 

WEBS-PA-2IP 

WEBS-PA-2IP-12

 Area Paging Units are designed to mount on a wall or pole, for use with 

WEBS-CONTACT

 as part of an IP-based Wide-area Emergency Broadcast System.   

 
NOTE: 

WEBS-CM-2

 requires a separate dedicated line regulated power supply or Power over Ethernet (PoE).  

 
 

II.  Wall Mounting 

 
The Area Paging Unit is held to the wall with 4 #10 screws.  Remove the cap and rotate front wrap from the back 
mounting plate.  Install two #10 screws in order to hold the top section of the back plate to the wall.  Note that the 
screws should be located so that the Area Paging Unit will be at the desired height and in the correct position to 
receive any conduit connections. 
 
Mount the back plate on the wall using the two keyholes on the top rear of the unit to the two screws mounted to 
the wall. Install two additional #10 screws of the appropriate type in the holes in the lower portion of the back plate.  
Tighten all four screws. 
 
 

III.  Pole Mounting 

 
For pole mounting, model 

ETP-PMKT

 Pole Mount Kit is recommended to strap the unit to a pole.  Model 

ETP-

PMKT-TOOL

 is the required tool.  Other banding solutions are also available. 

 
 

IV.  Wiring 

 
Electric power and the communication line can be brought into the unit in one of two ways: 
 

1. There are two large openings in the back of the unit to allow the unit to be mounted over a flush 

mounted standard electrical outlet box and/or flush mounted telephone connector box. 

   
2. There are two conduit openings available on the bottom of the unit for connection of power and/or 

communication line. 

 
Install conduit to hole(s) in bottom of unit, if this method is being used, and bring power line and/or communication 
line to inside of unit. 
 
The 

WEBS-AMP-2

 amplifier, loud speakers, and 

WEBS-CM-2

 communications module are installed prior to 

shipment.   
 
Connect the 

WEBS-AMP-2

 amplifier audio input to the audio line level output of the 

WEBS-CM-2

 

Connect 

WEBS-AMP-2

 amplifier trigger pair (blue and orange) to either of the aux. outputs of 

WEBS-CM-2

. Refer 

to the 

WEBS-CM-2

 Manual for information regarding the programming of your communications module. 

 
For the 

WEBS-PA-2IP

, connect the input power supply of the 

WEBS-AMP-2

 amplifier to 120VAC - 240VAC, 60Hz 

(wiring: brown - positive and blue - neutral).  

Reviews: