TEMPERATURE-CONTROLLED 

LEAD-FREE SOLDERING STATION

RX-852AS

Thank you for buying a 

goot

 soldering station.  Your new soldering station has been 

engineered and manufactured to the 

goot

 high standards for dependability, ease of operation, 

and operator safety.  If you follow the instructions and safety precautions in this manual and 
use the soldering station properly and only for what it is intended, you will enjoy years of safe, 
reliable service.  Thank you again for buying a 

goot

 soldering station.

WARNING

Before using the soldering station, read the Operation Manual. 
Failure to follow the safety precautions and instructions in this 
manual could result in serious injury and property damage.

 

OPERATION MANUAL

KEEP THIS MANUAL FOR FUTURE REFERENCE

TAIYO ELECTRIC IND.CO.,LTD.

Soldering Iron Stand is included.
Soldering iron stand usage is described in this manual.

Tip is not included. 

Please buy it separately.

Ver.2

Содержание Goot RX-852AS

Страница 1: ...dering station properly and only for what it is intended you will enjoy years of safe reliable service Thank you again for buying a goot soldering station WARNING Before using the soldering station read the Operation Manual Failure to follow the safety precautions and instructions in this manual could result in serious injury and property damage OPERATION MANUAL KEEP THIS MANUAL FOR FUTURE REFEREN...

Страница 2: ...ury CAUTION Failure to obey a safety caution may result in a minor or moderate injury to yourself or to others Always follow the safety precautions to reduce the risk of electric shock fire or personal injury Safety Mark Definitions Following the WARNINGS and CAUTIONS in this manual will allow for the safe and proper use of the soldering station and should protect the operator from injury and oper...

Страница 3: ... 24 5 Maintenance 25 5 1 How to Change the Tip 26 5 2 How to Change the Grip Rubber 27 5 3 How to change the Fuse 27 5 4 Housing Cleaning 28 5 5 How to Use and Maintain a Lead Free Soldering Iron 28 6 Troubleshooting 29 7 Replacement Tips 30 8 Replacement Parts 32 9 Parameters 32 10 Soldering Iron Stand ST 21 Instructions 34 MODEL RX 852AS Voltage 110 120 220 240V AC Power Consumption 145 170W Sol...

Страница 4: ...s are needed 8 Sleep function PAT The control unit automatically lowers the temperature when inactive for a preset period of time This can also be done manually by pressing and holding the key for 1 second The sleep function can be used in conjunction with the shutdown function 9 Sleep function release PAT Sleep mode can be exited by touching touch ing the wet sponge with the tip to cause tem pera...

Страница 5: ...d that the soldering station control unit and soldering unit function properly If any items are missing or damaged please contact your goot distributor Please store the packaging for future shipment or repair 2 2 Unpacking RX 852AS INSTRUCTION MANUAL KEY LOCK RX 852 HEAT SLEEP TEMP C AS Control Unit Soldering Unit RX 85GAS Operation Manual Power Cord Soldering See instruction p 34 Iron Stand ST 21...

Страница 6: ...ement fuse Tip Sold separately Slide Lever Grip Rubber Soldering Unit Connector Grip Adapter Rib to prevent mounting in the RX 802AS soldering unit Be sure to direction before the tip is integrating 4 2 calibration of the tip temperature is requires after attaching the tip Otherwise there may be some difference between the actual tip temperature add the set temperature of the unit CAUTION ...

Страница 7: ...ge Flashes when the tip temperature is out of the upper and lower temperature limits 5 KEY LOCK lamp Flashes while setting the Key Lock function Lights up when the Key Lock mode is set 6 KEY LOCK key Used to set the Key Lock function Used to lock and unlock the keypad 7 SETTING key This key is pressed when starting and completing the temperature setting process It is also used during the parameter...

Страница 8: ...ROPER APPAREL SAFETY GLASSES GLOVES AND MASK Do not wear loose clothing such as a necktie Tie up long hair Clothing or hair can burn on contact with the tip or surrounding heated parts 5 CONNECT TO THE SPECIFIED AC POWER SUPPLY The power voltage for this soldering station is indicated at the back of the control unit Never plug the soldering station into any other voltage 6 DO NOT ABUSE THE POWER C...

Страница 9: ...astic parts adapter ring and or soldering unit housing of the soldering iron unit could be damaged Position the soldering iron stand on a flat work surface bench Follow instructions in p 34 8 CONCERNING THE TIP Allow the tip to cool naturally Never use any other method to cool it down For example Water should never be poured or sprinkled on the tip to cool it down ...

Страница 10: ... If the set temperature is set at 200 C 392 F the sleep temperature must be 150 C 302 F or lower 4 1 Changing the Set Temperature Displays flashes Refer to the Parameters table on page 33 for the explanation of the display messages Press the key Setting completed Press the Press and hold the key until the display shows 340 key Example Changing the temperature from 250 C 482 F to 340 C 644 F When t...

Страница 11: ... Series MODEL TIP NO RX 80HRT 4 7C 0 RX 80HRT 0 8D 2 RX 80HRT 1 2D 2 RX 80HRT 1 6D 2 RX 80HRT 2 4D 1 RX 80HRT 3 2D 1 RX 80HRT 5 4D 0 RX 80HRT 3K 1 RX 80HRT 4 5K 1 RX 80HRT 4 5KH 1 RX 80HRT 5 5K 1 RX 80HRT 0 5C 3 RX 80HRT 1BC 1 MODEL TIP NO RX 80HRT SB 3 RX 80HRT B 1 RX 80HRT 2B 1 RX 80HRT LB 2 RX 80HRT LBJ 2 RX 80HRT 1C 4 RX 80HRT 2C 4 RX 80HRT 3C 2 RX 80HRT 3BC 1 RX 80HRT 4C 1 RX 80HRT BM 1 RX 80...

Страница 12: ...nto contact with the RX 852AS soldering tip the metallic parts in the thermometer conduct heat which transfers away from the RX 852AS tip This results in the thermometer indicating a slightly lower temperature than the one in the RX 852AS display Key Operation TEMP Display 4 3 Calibration Function 3 Example Where the set temperature is 300 C 572 F tip thermometer value is 295 C 563 F and the calib...

Страница 13: ...he key for over 3 seconds continuously changes to 150 While setting the sleep function the sleep lamp will flash The flashing of the sleep lamp will become faster 30 seconds before entering Sleep mode When the soldering station has entered Sleep mode the sleep lamp will change from flashing to continuously lit and the display will alternate between SLP and the temperature To use sleep function man...

Страница 14: ...urn off Set to 5 minutes before shipping Example Changing the sleep start time from 5 to 10 minutes Displays alternately Displays alternately Displays alternately Returns to the set temperature display Press and hold the key for over 3 seconds continuously Press the key three times Press the key until the display Setting completed Press and hold the key for over 3 seconds continuously changes from...

Страница 15: ...he key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately NOTE If the sleep sensitivity value DIF is set too high there is a possibility that the sleep function will be activated even during soldering If this happens reduce the sleep sensitivity value Sleep sensitivity value DIF can be set anywhere between 0 C 0 F and 20 C 36 F If the sleep sensitivity v...

Страница 16: ...MP Display 3 When the SUT Shutdown Start Time value is set to 0 the shutdown function is OFF When the unit enters shutdown the Sdn and the temperature are displayed alternately After the temperature drops below 50 C only the LED to the right of the last digit on the TEMP display remains lit To use the unit again after shutting down turn the power switch OFF wait a few seconds and then ON again to ...

Страница 17: ...and hold the key for over 3 seconds continuously Setting completed Returns to the set temperature display Press the Press the key 6 times to display At key Setting the soldering start time Tip temperatrue Power ON Time Set temperature AT Setting the soldering time AT DIF DIF 1 RX 852AS starts the soldering time count down when the tip temperature exceeds the set parameter 2 The alarm sounds after ...

Страница 18: ...Temperature Limit Upper Temperature Limit This function indicates to the operator with the sound of the alarm when the tip temperature goes past the set parameter The illustration on the right shows when the alarm will sound The diagonal lines represent outside the temperature parameters The alarm can be set from 3 to 100 C for the upper limit and the lower limit respectively To turn off this func...

Страница 19: ...vershoot will often occur when using the RX 85HSRT but Overshoot can be con trolled by setting the parameters 4 Press down the SET key for over 3 seconds 3 Press the UP key to set to 30 Tip type Differential time RX 80HRT series 5 RX 85HRT series 5 RX 85HSRT series 30 Standard of the differential time Returns to the set temperature display Setting completed Displays alternately Displays alternatel...

Страница 20: ...peration TEMP Display 4 9 Setting the Alarm Sound 3 Setting completed Returns to the set temperature display Press and hold the key for over 3 seconds continuously Press the key ten times Press the key to set to ON Press the key to set to OFF Press and hold the key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately Displays alternately ...

Страница 21: ...Operation TEMP Display 3 Press and hold the key for over 3 seconds continuously Displays alternately Press the key to change the format to F Fahrenheit F Press the key to change the format to C Celsius C Returns to the set temperature display Setting completed Press and hold the key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately Press the key eleven ...

Страница 22: ... using any three digit number from 001 to 999 When the code number is set correctly the number will flash 5 times If an incorrect code number is input the display will show NG and return to the initial display The Key Lock is set and released by the same procedure 4 11 Key Lock Function 1 3 Key Operation TEMP Display 2 Setting and Releasing the Key Lock Returns to the set temperature display Displ...

Страница 23: ...Press the key Press and hold the Example When changing the code number from 123 to 234 for over 3 seconds continuously Press the keys so that the present code number is displayed Press the key Input the desired new code number using the keys Displays alternately Returns to the set temperature display Press the key Setting completed key ...

Страница 24: ...nge temperature and or parameter settings Please keep this manual with authorized personnel only and in a safe place for future reference Resetting the Code Number 1 4 Key Operation TEMP Display 3 2 Press the key Press and hold the and the key simultaneously for over 3 seconds Press the keys so that the present code number is displayed Press the key Setting completed Displays alternately Displays ...

Страница 25: ...ersonnel only and in a safe place for future reference How to Restore Default Settings Setting completed The preset temperature is displayed Though the key lock can be released by doing the procedure shown above the code number cannot be reset To reset the code number follow the procedure for Resetting the Code Number shown on page 23 When doing the Resetting the Code Number procedure the alarm so...

Страница 26: ...s off as soon as the lever is slid forward to remove the tip 5 1 How to Change the Tip NOTE When changing to a different type of tip be sure to input the Tip No Refer to page 11 Since the heater is integrated into the tip replacement of only the heater or the tip is not possible A KEY LOCK RX 852 HEAT SLEEP TEMP C AS 4 Press any key on the keypad to start the flow of electricity to the heater 3 Pl...

Страница 27: ... hand so it does not come apart 1 Remove the screw Turn and pull the grip adapter to remove the grip rubber 5 2 How to Change the Grip Rubber 1 Place a slotted screwdriver in the slot to pull out the fuse box 2 Press both sides of the fuse box to remove it A spare fuse is stored on the other side of the fuse box Therefore turn the fuse box over or to the side to replace the fuse 5 3 How to Change ...

Страница 28: ...thin layer of solder is necessary The tin surface of a lead free soldering iron oxidizes easily Coating it with solder reduces oxidation levels Oxidation starts as soon as the tool is plugged in and begins to heat When operation is completed tin the tip with solder before turning the power off This protects the tip from oxidation when it starts heating up the next time it is in use A lead free sol...

Страница 29: ... items below before sending for service or repair The power does not go ON Check that the power cord is plugged in Check that the fuse is not blown The soldering iron tip does not heat up Check that the heater is not damaged Error message Cause Countermeasure The sensor or cord is damaged Replace the tip or soldering unit This message is also displayed when changing the tip but this is not an erro...

Страница 30: ...nt will exceed the capacity of the RX 802AS RX 85HRT B RX 85HRT 2BC RX 85HRT 3BC RX 85HRT 5BC 11 5 4 R 0 6 45 2 5 11 5 3 5 45 11 5 5 6 45 11 5 RX 85HRT 7BC RX 85HRT 3D RX 85HRT 5D RX 85HRT 7D 7 11 5 8 45 3 11 5 1 5 5 5 11 5 1 5 7 5 11 5 7 1 5 8 2 RX 85HRT 6K 14 6 3 45 9 0 RX 85HSRT B RX 85HSRT 2BC RX 85HSRT 3BC RX 85HSRT 1 6D 5 11 5 R 0 3 45 5 11 5 2 45 11 5 6 3 5 11 5 1 6 0 8 RX 85HSRT 2 4D RX 85...

Страница 31: ... 2CD RX 80HRT 3C RX 80HRT 3CD RX 80HRT 4C 45 φ2 11 5 1 2 2 φ3 45 φ 4 7 11 5 5 5 φ3 2 3 45 11 5 φ4 φ 4 7 12 6 45 RX 80HRT 4 7C RX 80HRT 0 8D RX 80HRT 1 2D RX 80HRT 1 6D φ4 7 45 8 5 5 φ 4 7 10 3 0 4 φ 0 8 φ 4 7 10 3 0 4 φ1 2 φ 4 7 10 5 0 5 φ1 6 3 2 RX 80HRT 2 4D RX 80HRT 3 2D RX 80HRT 5 4D RX 80HRT 3K φ 4 7 10 6 0 5 4 5 φ2 4 φ 4 7 10 6 5 0 5 φ3 2 5 4 5 7 1 φ5 4 10 5 7 4 1 2 φ3 45 6 0 φ 4 7 RX 80HRT ...

Страница 32: ... colours available Handy to differentiate stations being used for different tasks in the same workspace Grip Rubber Selection Grip rubber gray RX 80RB Anti Static Grip rubber black RX 80RB BK Grip rubber orange RX 80RB OR Grip rubber green RX 80RB GR 9 Parameters Term display panel letters Display Panel Unit Range Shipping Default Setting Set Temperature PT C F SSt 50 to 450 SSt 90 to 842 250 Tip ...

Страница 33: ...Sleep Timer ct Minute 0 00 to 999 5 Sleep Sensitivity diF C F 0 to 20 0 0 to 36 0 2 0 Shutdown Start time SUt Minute 0 to 999 60 Alarm At sec 0 3 to 30 Upper Limit H C F 3 to 100 5 to 180 50 Lower Limit L C F 3 to 100 5 to 180 50 Differential Time td cyc 0 50 5 Alarm Sound ON OFF ON Temperature Scale c F c ...

Страница 34: ... Use the hole of the sponge for better cleaning Alternatively push the soldering iron tip in and out of the brass wool a few times Stab not swipe Soldering Iron Stand ST 21 Instructions INSTRUCTION FOR USE Front Opening Adjusting Screws Heat Resistant Sponge ST 53SP Brass Wool ST 40BW ST 21MS To avoid rust do not pour water on the brass wool Sponge tray and hold ing flange of the front opening are...

Страница 35: ...TAIYO ELECTRIC IND CO LTD 35 ...

Страница 36: ... ELECTRIC IND CO LTD Customer service Contact your nearest distributor goot is registered trade mark of TAIYO ELECTRIC IND CO LTD Printed in Japan MAY 2015 A1240CX00 AOB HomePage www goot co jp E mail info goot co jp TAIYO ELECTRIC IND CO LTD ...