Page 1: ...Medio P200u Reader User s Guide Revision 1 0 October 2010...

Page 2: ...ATION CONTAINED HEREIN INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT IN NO EVENT SHALL TAGSYS BE LIABLE WHETHER IN CONTRACT TORT OR OT...

Page 3: ...me desk at Telephone 33 0 4 42 18 89 00 Fax 33 0 4 42 18 89 01 E Mail info tagsysrfid com Website http www tagsysrfid com Contact for Comments We welcome your feedback to help us provide high quality...

Page 4: ...ements stringent quality controls at all stages of its manufacturing process However should you find a defect with this product please notify your TAGSYS Quality Service representative using the dedic...

Page 5: ...______________________________________________ 9 2 2 1 IN EUROPE CE AND RTTE DIRECTIVES _____________________________________________ 9 2 2 2 IN USA FCC DIRECTIVE _____________________________________...

Page 6: ...SOLUTE MAXIMUM RATINGS______________________________________________________ 22 7 2 DC CHARACTERISTICS_____________________________________________________________ 22 8 WARRANTY CONDITIONS____________...

Page 7: ...below will further increase the lifetime of this device Keep the device and all parts and accessories out of the reach of small children Keep the device dry Precipitation humidity and liquids contain...

Page 8: ...perating Environment When connecting the device or any accessory to another device read its user s guide for detailed safety instructions Do not connect incompatible products As with all RF equipment...

Page 9: ...and 38 dB A m in US The Medio P200u meets these limits 2 2 1 In Europe CE and RTTE Directives The Medio P200u complies CE Declaration of Conformity granted with the European EMC directive The Medio P...

Page 10: ...separation between the equipment and receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Consult the dealer or an experienced radio TV techn...

Page 11: ...esigned to operate with the antennas listed below and having a maximum gain of 35 dBi Antenna not included in this list or having a gain greater than 35 dBi are striclly prohibited for use with this d...

Page 12: ...the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European Directive 2002 96 EC in order to be recycled or disma...

Page 13: ...ed in self check stations The Medio P200u Tag readers are easy to integrate because of its small size USB 1 1 communication link 3 2 Key Features Table 1 Medio P200u Key Features Description Medio P20...

Page 14: ...rovided for test and debug operations on Windows XP 200x Vista and Seven platforms Tagsys Legacy Software Development Kit including o DLLs and ActiveX o Library Software Development Kit Documentation...

Page 15: ...1 below shows the front panel which is dedicated to the RF connection Any of the following antennas can be connected to the standard SMA connector LW 1 Aero LI L SA3 L SA4 L SA4 SHD Figure 1 Front pa...

Page 16: ...ime and click next to proceed with the installation Select Install from a list or specific location Advanced and then click Next Select Search for the best driver in these locations and click the Brow...

Page 17: ...tag to be used In addition Px Explorer can display additional information such as the Product Reference and Firmware version and revision This section describes how to start with Px Explorer 5 1 Insta...

Page 18: ...8 25 Revision 1 0 October 2010 Once the correct folder is selected click Next Click Next to start the installation process A shortcut will be created on your desktop and a program group will be create...

Page 19: ...k yes Open the Communication Settings window CTRL C and check the COM port number and the communication speed The default communication speed for the Medio P200u is 115200 Bauds Click OK Now Px Explor...

Page 20: ...the Detect button to automatically detect the tag type Select the desired operation Read or Write and then click OK All the necessary windows to perform the desired action will be automatically displa...

Page 21: ...4 8 x 2 7 x 1 2 inches Weight 150 g DC power 12 VDC nominal Chip compatibility C210 C240 C270 C370 C370L C370S ISO 15693 Communication interface USB 1 1 RF Output Power 1W Typical Power consumption 3...

Page 22: ...RFOn Supply Current RFOn VSupply 12V Antenna connected AERO LI 271 mA LSA 2 290 mA LSA 3 276 mA IOpen Supply Current RFOn No connection on RF Connector 202 MA TOp Operating Tempature 0 55 C VUSB Suppl...

Page 23: ...as defective by TAGSYS and returned according to the return procedure defined below in such case TAGSYS will at TAGSYS option either replace every defective Product by one new Product or refund the p...