background image

 

25.02.2009/KLLA

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 

Villavent

 

VR 400 DCV/DE 
VR 700 DCV/DE 

 

    

 

 

 

 

 

  Installationsanweisung 

 

  Installation instructions 

 

 

 

 

 

 
 
 

Summary of Contents for Villavent VR 700 DCV

Page 1: ...25 02 2009 KLLA Villavent VR 400 DCV DE VR 700 DCV DE Installationsanweisung Installation instructions...

Page 2: ...h der Installation Seite 13 Einstellungen vor Inbetriebnahme Seite 13 Einstellen der Luftmenge Seite 14 SCHALTPLAN Seite 15 INTRODUCTION Villavent ventilation units with heat recovery have been manufa...

Page 3: ...n und sicherstellen da kein direkter Kontakt zwischen dem Ger t und dem Geb ude besteht 1 Inspection hatch 8 Duct from cookerhood 125 only for VR 400 DCV B 2 Sound attenuators inlet extract 9 Flexible...

Page 4: ...G THE UNIT POSITIONING AND ACCESS Fig 1 The unit should preferably be installed in a separate room e g storeroom laundry room or similar The unit is produced for installation on the wall but can alter...

Page 5: ...5 1 Schlafen 1 Bedroom 2 Wohnen 2 Living room 3 K che 3 Kitchen 4 Bad HWR 4 Bathroom Laundry room 5 Windfang 5 Hall 6 Abstellraum 6 Storeroom Fig 2...

Page 6: ...llten w hrend der Lagerung und Installation verschlossen sein Die Aussenwandabdeckung und die Dachhaube m ssen der Bauweise entsprechend installiert werden DUCT SYSTEM General Fig 2 Air to and from th...

Page 7: ...mit ab Bei Verwendung von anderen Kanalsystemen bitte die dort beiliegende Montageanleitung beachten Duct connections Fig 3 Secure all joints between ducting and Tee pieces duct connectors reducers e...

Page 8: ...8 Auslass Deckenmontage Inlet diffusor ceiling mounted Abluftventil Extract louvre Flex Schalld m Ventilanschl Flexible silencer with frame Fig 6 125 mm 100 mm 100 125 160 mm 100 125 mm...

Page 9: ...einstimmen sind die Ventilatoren neu einzujustieren siehe Inbetriebnahme Grundeinstellung DIFFUSERS LOUVERS Inlet diffusers extract louvers and cookerhood Fig 6 Mount inlet diffusers in all living roo...

Page 10: ...en laundry rooms etc Install doors with slot in the frame doors without door sill or slots vents in doors wall min 70 cm 2 free area per extract diffuser Fireplace kitchen ventilator tumble dryer etc...

Page 11: ...ion and cable for potential free signal to unit When opening the timer operated damper in the cookerhood the fans will automatically go to maximum capacity Install a 2 lead wire for potential free sig...

Page 12: ...DC to valve motor is provided from terminals GND WH on main PCB PCU EC in unit Operation voltage 24V AC to motor by way of separate transformer Example of valve motor Regin type MVT57 Example of valve...

Page 13: ...gabe des Volumenstromes ber die Fernbedienung mu in l s erfolgen Umrechnung von m h in l s Luftmenge in m h dividiert durch 3 6 ergibt Luftmenge in l s The technical information you can find in the ca...

Page 14: ...2 und Raumh he 2 4 m erforderliche Einstellung der Luftmenge auf Normalstufe auf 180 m 3 h bzw 50 l s Siehe auch Ausl sse Einstellung der Luftmenge COMMISSIONING Checklist after installation NB If sta...

Page 15: ...r more remote panels type CD Menu selector choose function and move in menus Confirm button to confirm choice Back button to go back in menu level Display information for operation settings changes et...

Page 16: ...l endringer forbeholdes Vi f rbeh ller oss r tten till ndringar utan f reg ende meddelande Vid eventuella fr gor ang aggregatet v nligen kontakta ert f rs ljningsst lle installat r nderungen vorbehalt...

Reviews: