background image

User Manual

Please read the user manual carefully

before start using the device.

User Manual

SR-A Series

Summary of Contents for Nttworks SR-A Series

Page 1: ...User Manual Please read the user manual carefully before start using the device User Manual SR A Series ...

Page 2: ...tting 7 3 4 Ringtone Repeat Setting 8 3 5 Delete the Registered Bell 8 3 6 Group Bell Registration 9 3 7 Clear Bell Registration 9 3 8 Rolling Mode Setting 10 3 9 Rolling Interval Time Setting 10 4 Additional Function Setting 4 1 Test Mode 11 4 2 Group Number Setting 11 4 3 Initialization 11 4 4 Wireless Data Copy 12 4 5 Channel Number Setting 12 4 6 Delay Time Setting 12 4 7 Repeater Time Setting...

Page 3: ...mm 600g FND Red color 7 segment Touch 6ch White 1 High performance RF IC Voice IC 2 Firmware update manage bell data ringtones 3 Touch Panel Key 4 Wireless data copy 5 Improved working range Intenna Receiver Display monitor Bracket Adapter DC 12V 1A Manual FRONT SIDE Enter the function Exit from the function Save the function Decrease the setting value Turn down the volume Move to the next digit I...

Page 4: ...on Rolling Mode Setting Rolling Interval Time Setting Test Mode Group Number Setting Initialization Wireless Data Copy Channel Number Setting Delay Time Setting Repeater Time Setting Up to 10 digits 1 11 12 22 Voice 0 Infinity 01 99 Infinity 0 1 9 Up to 10 digits Up to 10 digits Up to 10 digits 0 OFF up to 10 0 Push out 1 9 Rolling 0 Deactivate 01 99 rE Receiving SE Sending 01 99 00 99 0 Deactivate ...

Page 5: ...ress FUN to set alphabet or special characters Press enter after set the number 3 Press the call bell If the bell is already registered press ENT to re register 4 Press ESC to exit from the function mode Press the bell Saved 2 F 1 ENT ENT 3sec FUN 3 2 Ringtone Setting F2 3 Select the ringtone by Select the ringtone 4 Press ENT to save ENT FUN 1 Press FUN for 3sec to enter the function mode 2 Press...

Page 6: ...ing F4 1 F4 3 3 Display Time Setting F3 Set display time 3 Set the display time by Range 1 99sec Default 10sec Infinity remove from the display by ESC 4 Press ENT to save 10 F3 ENT FUN 1 Press FUN for 3sec to enter the function mode 2 Press twice and then press ENT Display time setting 3sec Twice 1 Press FUN for 3sec to enter the function mode 2 Press 3 times and then press ENT Ringtone repeat sett...

Page 7: ... existed 5 Press ESC to exit from the function mode 1 F5 ENT FUN 1 Press FUN for 3sec to enter the function mode 2 Press 4 times and then press ENT Delete the registered bell 3sec 4 times 4 Select the ringtone by and then press ENT Select the ringtone Press enter after set the number 3 Set the group number by and then press ENT Range 1 99 3 6 Group Bell Registration F6 Register call bells by differ...

Page 8: ...re register 5 Press ESC to exit from the function mode 1 F7 4 Press ENT to save Set the number of rolling 3 Set the number of rolling by Range up to 10 Default 0 0 Function OFF 3 8 Rolling Mode Setting F8 Receiver will show the received calls by circulation mode 0 F8 1 Press FUN for 3sec to enter the function mode 2 Press 6 times and then press ENT Clear bell registration ENT FUN 3sec 6 times 1 Pr...

Page 9: ... ENT Version information Press ENT to complete the test 1 1 2 3 4 3 4 2 Set the interval time 3 9 Rolling Interval Time Setting F9 3 Set the interval time of rolling by Range 0 9 Default 0 0 Push out mode 4 Press ENT to save 0 F9 1 Press FUN for 3sec to enter the function mode 2 Press 8 times and then press ENT Rolling interval time setting ENT FUN 3sec 8 times 1 Press FUN for 5sec to enter the ex...

Page 10: ...en it uses with the multi transmitter 2 Press once and then press ENT Group number setting 3 Set the group number by Range 1 99 Default 0 Set the group number 4 Press ENT to save 1 Press FUN for 5sec to enter the extension mode ENT FUN 5sec 3 times 2 Press 3 times and then press ENT Wireless data copy 1 Press FUN for 5sec to enter the extension mode ENT FUN 5sec Twice 2 Press twice and then press ...

Page 11: ...s FUN for 5sec to enter the extension mode The receiver will ignore the same signal during the delay time 3 Set the delay time by Range 0 99 Default 5 Set delay time 4 Press ENT to save 5 E6 4 6 Delay Time Setting E6 ENT ENT FUN 5sec 6 times 2 Press 6 times and then press ENT Repeater time setting 1 Press FUN for 5sec to enter the extension mode 3 Set the repeater delay time by 4 7 Repeater Time S...

Page 12: ...ance www syscallglobal fr 0033 0 1 84 17 61 81 contact syscall fr 242 boulevard de Stalingrad 94500 Champigny sur Marne France NTTWORKS CO LTD 413 9 NTTWORKS Bldg Galhyun Dong Eunpyong Gu Seoul Korea Manufacturer ...

Reviews: