background image

Shower System

 

S-4401

Installation Brief

1      2      3      4

Pipe

Sealant

Plumbers

Putty

Tools & Materials

Need Help?

Contact Symmons customer service 

at (800) 796-6667, (781) 848-2250,

[email protected]
Mon - Fri 7:30 am - 7:00 pm EST

Please check Symmons website

for technical help, the latest product 
information and warranty policy.
www.symmons.com/service

Carrington

Decorative Finish Code

append to part numbers if applicable

-STN Satin Nickel

              --   Chrome (standard)

4) 

Install piping, fittings and 

control valve 

Piping and fittings not supplied

 ■

Control Valve

Install valve through cutout hole in 

wall as specified in figure 2 below and 

dimension illustration on page 2. 

 ■

Showerhead (S on valve)

Pipe from outlet port on valve marked 

S

 

to showerhead mounting arm location.

 ■

Hot & Cold Supply (H & C)

Pipe hot water supply to valve input 

marked 

H

 and cold water supply to 

valve input marked 

C

.

 Rough-in Installation

Control valve, piping & fittings

Reference rough-in dimension illustration 

on page 2 as required.

1) 

Determine wall thickness

 ■

 

Determine type of wall and wall 

thickness where valve will be mounted.

 ■ Consider whether to use mounting plate 

by reviewing figure 2 below.

 ■ Skip ahead to 

Step 3

  if mounting   

plate will not be used.

2) 

Attach mounting plate to valve

Seat mounting plate against valve 

assembly as illustrated in figure 1.

3) 

Attach protective shield

 ■ Reference figure 2 to determine 

whether shield is required.

 ■ Attach plastic protective shield by 

snap fitting over end of valve spindle.  

Figure 1

  

Mounting plate

 

wall cutout hole size

3-1/2" ( 89 mm) min

       4" (101 mm) max

Finished wall must be

flush with back side of 

protective shield surface

finished wall

Dry wall, plaster or other type wall

   

1/2" (13 mm) or greater

Protective shield

"snap on-off" 

(required when

 mounting plate

 is not used)

2" ± 1/2"

(51 mm ±13 mm)

pipe centerline  

to finished wall

 wall cutout hole size

3-1/2" ( 95 mm) min

       4" (101 mm) max

finished

 wall

Ensure valve’s

mounting plate

is flush against

inner wall

Walls for using T-177 mounting plate

 

Fiberglass or acrylic walls (required)

 

Plaster or other type walls (optional)

    1/16" (2 mm) min  

 1/2" (13 mm) max

p/n T-176 p/n T-177

Protective shield

When mounting plate is used, 

then shield is optional for 

protecting end of valve during 

installation. 

 

"snap on-off"

Figure 2  

Mounting valve

Model Number

S-4401 Shower System

Summary of Contents for Carrington Shower System

Page 1: ...thickness where valve will be mounted Consider whether to use mounting plate by reviewing figure 2 below Skip ahead to Step 3 if mounting plate will not be used 2 Attach mounting plate to valve Seat mounting plate against valve assembly as illustrated in figure 1 3 Attach protective shield Reference figure 2 to determine whether shield is required Attach plastic protective shield by snap fitting o...

Page 2: ...m 7 1 2 diameter 191 mm tub spout supply plug 1 2 13 mm 2 1 2 51 mm 13 mm pipe centerline to finished wall Note 2 1 2 14 NPT mounting plate Notes 1 2 Notes 1 Valve spindle can be further extended through thicker walls by removing mounting plate 2 Dimension applies when mounting plate is not used 3 Dimensions subject to change without notice Temptrol control valve S 4001 BODY approx 27 686 mm appro...

Page 3: ...p screw adjust Seat repair kit TA 4 Temptrol Control Valve Tub supply plug Shower supply Volume spindle TA 25A 5 16 Allen wrench Cold seat Hot seat Parts Assembly Temptrol Shower Control Valve S 4001 BODY Replacement Parts and Special Tools Part Number Description TA 4 Hot and cold seat repair kit requires tools p n T 35A and T 35B TA 9 Control spindle washer repair kit TA 10 Control spindle inclu...

Page 4: ...ssure balancing piston which is the heart of the valve Remove control spindle assembly Shake spindle assembly and listen for clickingnoise Pistonshouldbefreetoslide back and forth the full length of its travel Trouble Shooting Chart Problem Cause Solution Valve will not pass water Both hot and cold water supplies are not turned on Turn on both supplies Valve will not operate unless both hot and co...

Reviews: