background image

V5, V7, V8

Active Studio Monitor

User Manual

Summary of Contents for 520888

Page 1: ...V5 V7 V8 Active Studio Monitor User Manual ...

Page 2: ...Thomann GmbH Hans Thomann Straße 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 Internet www thomann de 27 04 2022 ID 520888 520889 520890 ...

Page 3: ... 1 3 Symbols and signal words 7 2 Safety instructions 10 3 Features 14 4 Installation 15 5 Connections and operating elements 17 6 Technical specifications 20 7 Plug and connection assignment 26 8 Troubleshooting 29 9 Protecting the environment 31 Table of Contents V5 V7 V8 3 Active Studio Monitor ...

Page 4: ...4 V5 V7 V8 Active Studio Monitor ...

Page 5: ...ailable to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We there fore reserve the right to make changes without notice Please refer to the latest version of the user manual which is ready for download under www thomann de General information V5 V7 V8 5...

Page 6: ... Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please contact our technical hotline Service If you have any problems with the device the customer service will gladly assist you General information 6 V5 V7 V8 Ac...

Page 7: ...nectors and controls are marked by square brackets and italics Examples VOLUME control Mono button 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual Letterings General information V5 V7 V8 7 Active Studio Monitor ...

Page 8: ...t can result in death or serious injury if it is not avoided CAUTION This combination of symbol and signal word indicates a pos sible dangerous situation that can result in minor injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of dange...

Page 9: ...Warning signs Type of danger Warning suspended load Warning danger zone General information V5 V7 V8 9 Active Studio Monitor ...

Page 10: ... physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety Safety DANGER Danger for children Ensure that plastic bags packaging etc are disposed of properly and are not within reach of babies and young children Choking hazard Ensure that ...

Page 11: ... advice from a registered electrician WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as a safety cable or a safety chain CAUTION Possible hearing damage The device can produce volume levels that may cause temporary or permanent hearing ...

Page 12: ...n damage the unit When operated in harmful ambient conditions dust smoke nicotine fog etc the unit should be maintained by qualified service personnel at regular intervals to prevent overheating and other malfunction NOTICE Power supply Before connecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual cur...

Page 13: ...ibly react with the coating of your surface and after some time cause permanent dark stains In case of doubt do not put the rubber feet directly on the surface and use a suitable underlay if neces sary i e felt pad floor protectors or similar Safety instructions V5 V7 V8 13 Active Studio Monitor ...

Page 14: ...on transformer Frequency range from 39 Hz 25 kHz 70 watt bi amping amplifier class D n V8 2 way system 8 low mid speaker and Air Motion transformer Frequency range from 33 Hz 25 kHz 90 watt bi amping amplifier class D n Switch for adapting treble and bass to the room acoustics n Inputs XLR panel socket jack socket balanced RCA socket n Input sensitivity adjustable n Standby function Features 14 V5...

Page 15: ...table for transport or storage respectively Create all connections while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards NOTICE Possible property damage by magnetic fields Loudspeakers produce a static magnetic field Therefore maintain an appropriate distance to devices that can be adversely affected ...

Page 16: ...ting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand Installation 16 V5 V7 V8 Active Studio Monitor ...

Page 17: ...es it switches to standby mode The control LED on the front panel then lights up red As soon as the speaker box receives a signal it switches back to normal mode and the LED will turn blue Control LED on the front panel Connections and operating elements V5 V7 V8 17 Active Studio Monitor ...

Page 18: ... ö Rear panel Connections and operating elements 18 V5 V7 V8 Active Studio Monitor ...

Page 19: ...input sensitivity 4 dBu 10 dBV 5 Connection for playback devices with line level unbalanced designed as a RCA socket 6 Power Mains switch Turns the device on and off 7 IEC chassis plug with fuse holder for the power supply 8 Connection for a balanced input signal designed as a XLR panel socket 3 pin 9 Connection for a balanced input signal designed as a jack socket Connections and operating elemen...

Page 20: ...et unbalanced 1 jack socket mono balanced Voltage supply IEC chassis plug C14 Input impedance 20 kΩ balanced 10 kΩ unbalanced Input sensitivity 320 mV pink noise 100 dB SPL in 1 m distance volume control at 100 Output power Bass mid range amp 50 W Treble amp 20 W Amp class Class D V5 item no 520888 Technical specifications 20 V5 V7 V8 Active Studio Monitor ...

Page 21: ...y 3 0 kHz Power consumption 130 W Supply voltage 100 240 V 50 60 Hz Fuse 5 mm 20 mm 1 6 A 250 V slow blow Dimensions W H D 180 mm 288 mm 295 mm Weight 4 2 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 20 80 non condensing Technical specifications V5 V7 V8 21 Active Studio Monitor ...

Page 22: ... Voltage supply IEC chassis plug C14 Input impedance 20 kΩ balanced 10 kΩ unbalanced Input sensitivity 320 mV pink noise 103 dB SPL in 1 m distance volume control at 100 Output power Bass mid range amp 50 W Treble amp 20 W Amp class Class D Sound pressure level SPL max in 1 m distance 103 dB V7 item no 520889 Technical specifications 22 V5 V7 V8 Active Studio Monitor ...

Page 23: ...n 130 W Supply voltage 100 240 V 50 60 Hz Fuse 5 mm 20 mm 1 6 A 250 V slow blow Dimensions W H D 220 mm 335 mm 295 mm Weight 6 0 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 20 80 non condensing Technical specifications V5 V7 V8 23 Active Studio Monitor ...

Page 24: ... Voltage supply IEC chassis plug C14 Input impedance 20 kΩ balanced 10 kΩ unbalanced Input sensitivity 320 mV pink noise 106 dB SPL in 1 m distance volume control at 100 Output power Bass mid range amp 70 W Treble amp 20 W Amp class Class D Sound pressure level SPL max in 1 m distance 106 dB V8 item no 520890 Technical specifications 24 V5 V7 V8 Active Studio Monitor ...

Page 25: ...n 130 W Supply voltage 100 240 V 50 60 Hz Fuse 5 mm 20 mm 1 6 A 250 V slow blow Dimensions W H D 250 mm 398 mm 330 mm Weight 7 8 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 20 80 non condensing Technical specifications V5 V7 V8 25 Active Studio Monitor ...

Page 26: ... core plus shielding are typical representatives of the unbalanced transmission One conductor is ground and shielding while the signal is trans mitted through the core Unbalanced transmission is susceptible to electromagnetic interference especially at low levels such as microphone signals and when using long cables In a professional environment therefore the balanced transmission is preferred bec...

Page 27: ...e shifted signals the interfering signal is completely neutralized The result is a pure signal without any noise inter ference 1 Signal in phase 2 Signal out of phase 3 Ground 1 4 TRS phone plug mono bal anced Plug and connection assignment V5 V7 V8 27 Active Studio Monitor ...

Page 28: ...Signal out of phase 4 Shielding on plug housing option Drawing and table indicate the pin assignment of an RCA plug 1 Signal 2 Ground shielding XLR plug balanced RCA connection Plug and connection assignment 28 V5 V7 V8 Active Studio Monitor ...

Page 29: ...wer switch No sound 1 Check the position of the volume control 2 Check the correct connection of the signal cables 3 Check the signal cables and or the signal source 4 Try using another signal cable Once the music gets loud the high frequencies slump Maybe overheating is imminent Provide better ventila tion or reduce the volume Distortion is audible Excessive input signal Reduce the signal level T...

Page 30: ... that all audio devices are connected to the same power circuit and thus share the same ground ref erence If the procedures recommended above do not succeed please contact our Service Center You can find the contact information at www thomann de Troubleshooting 30 V5 V7 V8 Active Studio Monitor ...

Page 31: ... and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country I...

Page 32: ...Notes 32 V5 V7 V8 Active Studio Monitor ...

Page 33: ...Notes V5 V7 V8 33 Active Studio Monitor ...

Page 34: ...Notes 34 V5 V7 V8 Active Studio Monitor ...

Page 35: ......

Page 36: ...Musikhaus Thomann Hans Thomann Straße 1 96138 Burgebrach Germany www thomann de ...

Reviews: