background image

ATENCIÓN:

 lea, entienda y siga las instrucciones de seguridad contenidas en este 

manual antes de operar esta herramienta.

WARNING: read, understand and follow the safety rules in this manual, before operating this tool.

COMP410 COMP425B

COMP6100 COMP6200

COMP550B

COMP425K

COMP6120V

COMPRESOR  

DE AIRE

AIR COMPRESSOR

MANUAL DE USUARIO Y 

GARANTÍA.

USER’S MANUAL AND WARRANTY.

Summary of Contents for COMP410

Page 1: ...ual antes de operar esta herramienta WARNING read understand and follow the safety rules in this manual before operating this tool COMP410 COMP425B COMP6100 COMP6200 COMP550B COMP425K COMP6120V COMPRE...

Page 2: ...s de seguridad para compresores de aire Caracter sticas Especificaciones t cnicas Instrucciones de operaci n Mantenimiento Solucionador de problemas Notas Garant a 11 11 11 12 12 13 13 14 15 17 18 20...

Page 3: ...entre en la herramienta aumentar el riesgo de choque el ctrico No abuse del cable No usar nunca el cable para llevar levantar o desenchufar la herramienta el ctrica Mantenga el cable lejos del calor a...

Page 4: ...ramienta el ctrica si el interruptor no acciona encendido y apagado Cualquier herramienta el ctrica que no pueda controlarse con el interruptor es peligrosa y debe repararse Desconecte la clavija de l...

Page 5: ...ctar y antes de encender no exista alguna parte suelta o sobre el compresor Aseg rese de leer todas las etiquetas en los contenedores pinturas u otros materiales para ser rociados Estrechamente siga t...

Page 6: ...UDAL M XIMO 224 L min 7 9 CFM PRESI N M XIMA 115 PSI VELOCIDAD EN VAC O 3 450 r min POTENCIA 2 HP HORAS DE USO M XIMO 6 horas NIVEL DE RUIDO 88 dB TEMPERATURA DE TRABAJO 85 C 90 C PESO 21 4 kg 47 1 lb...

Page 7: ...udie ran intervenir con el flujo de aire El cabezal y la cubierta del compresor de aire est n dise ados para permitir el correcto enfriamiento Si la hu medad es alta puede instalar un filtro de aire e...

Page 8: ...NTO ADVERTENCIA LA UNIDAD REALIZA CICLOS AUTOM TICAMENTE CUANDO SE LE SUMINIS TRA ENERG A CUANDO REALICE MANTENI MIENTO PODR A ESTAR EXPUESTO A FUENTES DE VOLTAJE AIRE COMPRIMIDO O PARTES M VILES PODR...

Page 9: ...oque el tubo de liberaci n de presi n y accesorios 9 Coloque el tubo de escape y apriete las tuer cas superior e inferior 10 Coloque la cubierta MOTOR El motor tiene un interruptor manual de pro tecci...

Page 10: ...a una salida el ctrica Verifique y remplace si es necesario Remueva y limpie o remplace Ajuste los accesorios Vea la secci n de Gu a de Soluci n de Problemas de Fugas de Aire EL MOTOR NO TRABAJA Caus...

Page 11: ...s should be used to prevent excessive voltage drop loss of power or overheating The table below shows the cor rect size to use depending on cord length and nameplate amperage rating of tools In case o...

Page 12: ...pment is not permitted Explosive combustible gases or gases detrimen tal to health may not be compressed Opera tion in hazardous locations is not permitted Any other use is not a as specified alterati...

Page 13: ...plug Do not use the compressor without first check ing the oil level It must be close to the red circle as viewed on the oil gauge NOTE the compressor is supplied without oil It must be filled before...

Page 14: ...ompressor operation Immediately upon arrival check equipment for both concealed and visible damages to avoid ex penses being incurred to correct such problems This should be done regardless of any vis...

Page 15: ...air pressure rotate the regulat ing valve clockwise To decrease the pressure rotate the regulating valve anti clockwise NOTE if you do not allow the air to discharge while you are setting the regulato...

Page 16: ...80 6 F SAE 30W ISO 100 SERVICE INSTRUCTIONS Air Filter Inspection and Replacement Keep the air filter clean at all times Do not ope rate the compressor with the air filter removed A dirty air filter...

Page 17: ...op when the accessory is used adjust the regulator following the instruc tions NOTE Adjust the regulated pressure under flow conditions while accessory is being used AIR LEAK FROM SAFETY VALVE Cause P...

Page 18: ...heck for low voltage conditions and or pro per extension cord 3 Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Bleed the line by pushing th...

Page 19: ...19 E N G L I S H User s Manual Notas Notes...

Page 20: ...dified by unauthorized or unqualified person URREA HERRAMIENTAS PROFESIONALES S A DE C V garantiza este producto por el termino de 1 a o en sus piezas componentes y mano de obra contra cualquier defec...

Reviews: