background image

Heatseeker VortexE Inverter Heat Pump 

Installation & User Manual

1

INSTALLATION & USER MANUAL

Summary of Contents for HEATSEEKER VORTEXE

Page 1: ...HeatseekerVortexE Inverter Heat Pump Installation User Manual 1 INSTALLATION USER MANUAL...

Page 2: ...ing com au Supreme Solar Pty Ltd ABN 88 007 400 213 New South Wales 19 24 Anzac Avenue Smeaton Grange NSW 2567 P 02 4648 4766 solar nsw supremeheating com au salesnsw supremeheating com au Queensland...

Page 3: ...instructions 06 2 3 Maintenance and winterizing 08 3 Technical specification 09 FOR INSTALLERS AND PROFESSIONALS 4 Transportation 10 5 Installation and maintenance 11 5 1 Notice before installation 1...

Page 4: ...nce in the operation range Air 15 C 25 C 1 3 ADVANTAGES OF DIFFERENT MODES The heat pump has two modes Smart and Silence They have different advantages under different conditions MODE RECOMMENDATION A...

Page 5: ...he heat pump can only be used with pool water It can NEVER be used to heat or cool other flammable or turbid liquid 1 4 2 When moving the heat pump do not lift the water union This will damage the tit...

Page 6: ...not store or use combustible gas or liquids such as thinners paints or fuels near the heat pump 1 4 6 If you detect any abnormal noises odours smoke or leaks from the heat pump immediately switch off...

Page 7: ...heat pump from the power supply during electrical storms 1 4 9 Please note that following codes are not failures CODES No water flow Anti freezing reminder Out of the operating range Insufficient wate...

Page 8: ...or off the heat pump Mode 1 Heating mode 2 Press to select Smart Silence mode Smart mode 100 20 capacity Silence mode 80 20 capacity 3 Wifi Setting Up Down Press to set desired water temperature Note...

Page 9: ...con on the top of screen will flash When finished defrosting the machine will switch automatically to the mode before defrosting Compulsory defrosting when the heat pump is heating and the compressor...

Page 10: ...e on the surfaces around the unit to prevent ant and insect ingress 2 3 2 Winterizing Sub Zero Climates In climates where the winter season reaches sub zero temperatures please disconnect from power s...

Page 11: ...00 Pool Volume Warm Climate Litres 30 000 40 000 50 000 Advised Flow Rate L min 70 100 135 Inlet Outlet mm 40 Compressor Linda Heat Exchanger Spiral titanium tube in PVC Casing Black ABS Noise Level 1...

Page 12: ...e heat pump please ensure the unit remains in an upright position at all times 4 2 When moving the heat pump do not lift the water union This will damage the titanium heat exchanger HeatseekerVortexE...

Page 13: ...ssional Unqualified installations may result in damage to the heat pump and or safety risks to the user 5 1 NOTICE BEFORE INSTALLATION 5 1 1 Plumbing connections must be made with solid PVC pipe Usage...

Page 14: ...15m from and to the heat pump 30m in total unless the ground is wet or the groundwater level is high A rough estimate of the heat loss per 30m is 0 6 kWh 2 000 BTU for every 5 C difference between th...

Page 15: ...m and the heat pump to prevent chemicals returning to the heat pump Failure to observe this instruction will void the warranty Independent System In line System FROM POOL TO POOL 3 WAY VALVE NON RETUR...

Page 16: ...Adjusting the Bypass A B HEAT PUMP BACK FILTER FILTER PUMP FROM POOL TO POOL 3 WAY VALVE CHLORINATOR NON RETURN VALVE OUT IN HeatseekerVortexE Inverter Heat Pump Installation User Manual 14...

Page 17: ...e the message clears the default display is the current water temperature Starting sequence will now begin ATTENTION Bypass Installation Operation without a bypass or with improper bypass adjustment m...

Page 18: ...ect to modification without notice 5 2 2 Heat pump installation 1 When the heat pump is running condensation will occur and drain from the bottom of the unit This is completely normal However consider...

Page 19: ...hing all wiring construction and re checking 1 Wiring Diagram A For power supply 240V 50Hz 2 Options for protecting devices and cable specification MODEL 9 KW 13 KW 17 KW Breaker Minimum Rated Current...

Page 20: ...he user is advised to start the water pump before the heat pump and turn off the heat pump before the water pump for long life circle 2 The user should start the water pump and check for any leakage o...

Page 21: ...outside acceptable operating range Engage electrician to confirm power supply refer to technical specifications E6 Excessive temperature differential between inlet and outlet water insufficient water...

Page 22: ...or failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Restart memory failure 18 F1 Compressor d...

Page 23: ...TING 1 APP Download Android mobile please download from iPhone please download from 2 Account registration a Registration by mobile number Email HeatseekerVortexE Inverter Heat Pump Installation User...

Page 24: ...b Mobile number registration 3 Create family Please set family name and choose the room of device Aus 61 HeatseekerVortexE Inverter Heat Pump Installation User Manual 22...

Page 25: ...airing the display window and the WIFI indicator flash After successful pairing the display window number is increased by 1 and the setting interface is automatically exited b Wifi reset When the WIFI...

Page 26: ...5 Operation a For heat pump with Heating function only HeatseekerVortexE Inverter Heat Pump Installation User Manual 24...

Page 27: ...After binding if your family members also want to control the device Please let your family members register the APP first and then the administrator can operate as below HeatseekerVortexE Inverter H...

Page 28: ...n your family members can log in as below Notice 1 The weather forecast is just for reference 2 APP is subject to updating without notice HeatseekerVortexE Inverter Heat Pump Installation User Manual...

Page 29: ...r heat pump components a two 2 year limited warranty from Supreme Solar Pty Ltd 2 19 Enterprise Drive Bundoora Victoria 3083 Phone 03 9460 4200 Email info supremeheating com au In field labour warrant...

Page 30: ...ould otherwise be implied in this agreement or in relation to the Product is hereby excluded 9 Where legislation implies in this agreement or in relation to the Product any condition or warranty and t...

Page 31: ...3 4 5 and 6 Whole agreement 15 This warranty and any warranties implied by law which are not capable of being excluded or modified from the whole warranty agreement between Supreme Solar Pty Ltd and...

Page 32: ...NOTES HeatseekerVortexE Inverter Heat Pump Installation User Manual 30...

Page 33: ...HeatseekerVortexE Inverter Heat Pump Installation User Manual 31...

Page 34: ...HeatseekerVortexE Inverter Heat Pump Installation User Manual 32 supremeheating com au 1300 787 978...

Reviews: