manualshive.com logo in svg
background image

   

S

UPER

S

UPER

S

ERVER

MicroCloud

5038ML-H12TRF

®

USER’S MANUAL

Revision 1.0

Проконсультироваться

 

и

 

купить

 

данное

 

оборудование

 

вы

 

можете

 

в

 

компании

 «

АНД

-

Системс

»  

адрес

: 125480, 

г

.

Москва

ул

.

Туристская

д

.33/1; site: https://andpro.ru 

тел

: +7 (495) 545-4870 email: [email protected] 

При

 

обращении

 

используйте

 

промокод

 AND-PDF 

и

 

получите

 

скидку

Содержание MicroCloud 5038ML-H12TRF

Страница 1: ...evision 1 0 Проконсультироваться и купить данное оборудование вы можете в компании АНД Системс адрес 125480 г Москва ул Туристская д 33 1 site https andpro ru тел 7 495 545 4870 email info andpro ru При обращении используйте промокод AND PDF и получите скидку ...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerci...

Страница 3: ...0SLE F motherboard and the SC939H R1K63BP chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the server into a rack and check out the server configuration prior to powering up the system If your server was ordered without the processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter ...

Страница 4: ...nfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC939H R1K63BP 3U server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed info...

Страница 5: ...v Preface Notes ...

Страница 6: ...2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Airflow 2 3 Mechanical Loading 2 3 Circuit Overloading 2 3 Reliable Ground 2 3 2 5 Installing the System into a Rack 2 4 Chapter 3 System Interface 3 1 Overview 3 1 3 2 Motherboard Nodes 3 1 Power Button LED 3 1 3 3 Power Supply Modules 3 2 Pow...

Страница 7: ... 1 Unpacking 5 1 5 2 Motherboard Installation Removal 5 2 5 3 Connecting Cables 5 2 Connecting Data Cables 5 2 Connecting Power Cables 5 2 5 4 I O Ports 5 3 5 5 Processor and Heatsink Installation 5 4 Installing an LGA1150 Processor 5 4 Installing a Heatsink 5 7 5 6 Installing Memory 5 8 How to Install Memory 5 8 Memory Support 5 8 Memory Population Guidelines 5 9 5 7 MicroLP Expansion Module 5 10...

Страница 8: ...s 6 7 6 7 Power Supply 6 8 Power Supply Replacement 6 8 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Configuration Data 7 1 How to Start the Setup Utility 7 2 7 2 Main Setup 7 2 7 3 Advanced Setup Configurations 7 4 7 4 Event Logs 7 23 7 5 IPMI 7 24 7 6 Boot Settings 7 27 7 7 Security Settings 7 29 7 8 Save Exit 7 30 Appendix A BIOS Error Beep Codes Appendi...

Страница 9: ...2TRF as listed below Four chassis fans FAN 0145L4 One passive heatsink each node SNK P0047PSR One air shroud each node MCP 310 93901 0B One 55 cm 30AWG cable each node CBL 0488L One 70 cm 30AWG cable each node CBL 0489L One 11 5 cm KVM SUVI 30 28AWG dual USB cable each node CBL 0218L One MicroLP module each node AOM CGP I2M One rail kit MCP 290 41803 0N Optional parts for 2 5 HDD support One 2 5 H...

Страница 10: ...ery Low Profile memory This equates to a maximum of 384 GB for the system Memory modules of the same size and speed should be used See Chapter 5 for details SATA A SATA controller integrated into the chipset provides a four port SATA 3 0 sub system on each node Each node supports two 3 5 SATA 3 0 HDDs or four 2 5 SATA 3 0 hard drives Rear I O Ports The rear I O panel on each node includes one KVM ...

Страница 11: ... ASP2400 PCIe2 0 x1 LPC COM1 KVM LPC HEALTH INFO 6 0Gb s LPC TPM1 2 Header Lynx Point DDR3 CHA Haswell H3 PCIe3 0_x8 VRM 12 5 SVID LPC I O NCT6776D PCIe x8 Micro LP Slot DDR3 CHB DIMM1 DIMM2 Far DIMM1 DIMM2 Far 4 UDIMM MISC VRs 1600 1333MHz 8 0Gb s x4 DMI II 5 0Gb FLASH SPI 128Mb SPI 1600 1333MHz 480Mb s USB2 0 X 2 2 USB Ports KVM SATA II 1 SATA Port 3 0Gb s USB3 0 X 1 5 0Gb s 1 USB Port Type A US...

Страница 12: ...iciency power supply comprised of two separate power modules This power redundancy feature allows you to replace a failed power supply without shutting down the system Cooling System The SC939H R1K63BP chassis includes four 9 cm fans located at the rear of the chassis Each node also has an air shroud to channel the airflow from the system fans to efficiently cool the components that generate the m...

Страница 13: ...ess Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 23511 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226...

Страница 14: ...1 6 SUPERSERVER 5038ML H12TRF User s Manual Notes ...

Страница 15: ...where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The server may have come with hardware to mount the system into a server rack If mounting to a rack with the rail kit follow the steps in the order given to complete the installatio...

Страница 16: ...ng a component from it You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work u...

Страница 17: ...ssible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connec tions other than the direct con...

Страница 18: ...immobile during shipping Release these screws just enough to allow the rails to slide apart Note the arrow on the rail which indicates the end that attaches to the front of the rack 4 Slide the rails apart far enough to match the depth of the rack Position the rails with the template and secure the front of each to the front of the rack with two flathead screws then secure the back of each rail to...

Страница 19: ...k they are unnecessary and regular screws should be used instead of thumbscrews 6 With one person on either side lift the system and slide it into the installed rails 7 After pushing the enclosure all the way into the rack use two roundhead screws on each side of the server to lock it into place Warning do not pick up the server with the front handles They are de signed to pull the system from a r...

Страница 20: ...The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Note this figure is for illustrative purposes only Always install servers to the bot tom of a rack first ...

Страница 21: ...Nodes Power Button LED The main power button on each of the nodes functions as both an on off switch and as an LED Pressing the button will alternately power on or remove power from the node See the table below for the LED indications LED Appearance Description Green The node is powered on and operating normally Solid Red The node is detecting an overheat condition 1Hz Blinking Red The node is det...

Страница 22: ...power module is not turned on or needs service Off AC power is not connected to the power module or the module needs service 3 3 Power Supply Modules Power Module LED Each of the power supply modules has its own LED to indicate the status of the module Figure 3 1 Node LED Indicator Figure 3 2 Power Supply Module LED Indicator Node LED Power Module LED ...

Страница 23: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Страница 24: ... el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux c...

Страница 25: ... u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES ﻓﻲ ﺍﻧﻚ ﺃﻥ ﻳﻤﻜﻦ ﺣﺎﻟﺔ ﻓﻲ ﺗﺘﺴﺒﺐ ﺍﺻﺎﺑﺔ ﺟﺴﺪﻳﺔ ﺍﻟﺮﻣﺰ ﻫﺬﺍ ﻳﻌﻨﻲ ﺧﻄﺮ ﺗ...

Страница 26: ...de instalación antes de conectar el sistema a la red de alimentación Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい ﺍﻟ ﺇﺭﺷﺎﺩﺍﺕ ﺍﻗﺮ ﺘﺮﻛﻴﺐ ﺗﻮﺻﻴﻞ ﻗﺒﻞ ﺇﻟﻰ ﺍﻟﻨﻈﺎﻡ ﻟﻠﻄﺎﻗﺔ ﻣﺼﺪﺭ לקרוא יש למקור המערכת חיבור לפני התקנה הוראות את מתח 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies v...

Страница 27: ...rt ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit dépend de l installatio...

Страница 28: ...wird bevor es auf den Chassisinnenraum zurückgreift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 ...

Страница 29: ... ou enlever des composants de systéme חשמלי ניתוק מפני אזהרה אזהרה החשמל מקורות מכל המערכת את לנתק יש להסיר ויש מהספק החשמלי כבל את התקנ לצורך המארז של הפנימי לחלק גישה לפני ת הסר או ת רכיבים ﻓﺼﻞ ﻳﺠﺐ ﺍﻟﻨﻈﺎﻡ ﺟﻤﻴﻊ ﻣﻦ ﻣﺼﺎﺩﺭ ﺍﻟﻄﺎﻗﺔ ﻭﺇﺯﺍﻟﺔ ﺍﻟﻜﻬﺮﺑﺎء ﺳﻠﻚ ﻣﻦ ﻭﺣﺪﺓ ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ ﻗﺒﻞ ﺇﻟﻰ ﺍﻟﻮﺻﻮﻝ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻤﻨﺎﻁﻖ ﻟ ﻠﻬﻴﻜﻞ ﺇﺯﺍﻟﺔ ﺃﻭ ﻟﺘﺜﺒﻴﺖ ﻣﻜﻮﻧﺎﺕ ﺍﻟﺠﻬﺎﺯ 경고 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터 연결...

Страница 30: ...l gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד ﻭﺍﻟﻤﺪﺭﺑﻴﻦ ﻭ ﻟﺘﺮﻛﻴﺐ ﺍﺳﺘﺒﺪﺍﻝ ﺃﻭ ﺧﺪﻣﺔ ﺍﻟﺠﻬﺎﺯ ﻫﺬﺍ ﻳﺴﻤﺢ ﺃﻥ ...

Страница 31: ... in Bereichen mit beschränktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich Advertencia Esta unidad ha sido diseñada para instalación en áreas de acceso restringido Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial cerradura con lla...

Страница 32: ...ﺤﻈﻮﺭﺓ ﺗﻢ ﺍﻟﻮﺻ ﻳﻤﻜﻦ ﺇﻟﻰ ﻮﻝ ﻣﻨﻄﻘﺔ ﻣﺤﻈﻮﺭﺓ ﻓﻘﻂ ﺍﺳﺘﺨﺪﺍﻡ ﺧﻼﻝ ﻣﻦ ﺧﺎﺻﺔ ﺃﺩﺍﺓ ﺃﻭ ﺃﻱ ﻟﻼ ﺃﺧﺮﻯ ﻭﺳﻴﻠﺔ ﻷﻣﺎﻥ ﻭﻣﻔﺘﺎﺡ ﻗﻔﻞ 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en...

Страница 33: ...ipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה סכנת קיימת פיצוץ תקינה לא בדרך והוחלפה במידה הסוללה של להחליף יש בסוג הסוללה את מ התואם חברת מומל יצרן צת הסוללות סילוק המשומשות לבצע יש היצרן הוראות לפי ﺧﻄﺮ ﻫﻨﺎﻙ ﻣﻦ ﺍﺳﺘﺒﺪﺍﻝ ﺣﺎﻟﺔ ﻓﻲ ﺍﻧﻔﺠﺎﺭ ﺍﻟﺒﻄﺎﺭﻳﺔ ﺻﺤﻴﺤﺔ ﻏﻴﺮ ﺑﻄﺮﻳﻘﺔ ﻓﻌﻠﻴﻚ ﺍﻟﺒﻄﺎﺭﻳﺔ ﺍﺳﺘﺒﺪﺍﻝ ﻓﻘﻂ ﺍﻟﻨﻮﻉ ﺑﻨﻔﺲ ﻳﻌﺎﺩﻟﻬﺎ ﻣﺎ ﺃﻭ ﻛﻤﺎ ﺃﻭ...

Страница 34: ... Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées Redundant Power Supplies Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り...

Страница 35: ...uidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing ﻗﺪ ﻟﻬﺬﺍ ﻳﻜﻮﻥ ﺍﻟ ﺠﻬﺎﺯ ﺍﺗﺼﺎﻻﺕ ﻋﺪﺓ ﺑﻮﺣﺪﺍﺕ ﺍﻟﻄﺎﻗﺔ ﺍﻣﺪﺍﺩ ﺇﺯﺍﻟﺔ ﻳﺠﺐ ﺍﻻﺗﺼﺎﻻﺕ ﻛﺎﻓﺔ ﻟﻌﺰﻝ ﺍﻟ ﻮﺣﺪﺓ ﻋﻦ ﺍﻟﻜﻬﺮﺑﺎء 경...

Страница 36: ...equipo debe cumplir con las normas de electricidad locales y nacionales ﻫﻨﺎﻙ ﺧﻄﺮ ﻣﻦ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺍﻟﺘﻴﺎﺭ ﻋﻠﻰ ﺍﻟﻤﻮﺟﻮﺩﺓ ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻠﻮﺣﺔ ﻳﻜﻮﻥ ﻋﻨﺪﻣﺎ ﺍﻟﻨﻈﺎﻡ ﻳﻌﻤﻞ ﻋﻨﺪ ﺣﺬﺭﺍ ﻛﻦ ﺧﺪﻣﺔ ﺍﻟﺠﻬﺎﺯ ﻫﺬﺍ 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het...

Страница 37: ...ﺍﻧﻴﻦ ﻭﺍﻟﻮﻁﻨﻴﺔ ﺍﻟﻤﺤﻠﻴﺔ ﺍﻟﻤﺘﻌﻠﻘﺔ ﺑﺎﻟﻜﻬﺮﺑﺎء Attention L équipement doit être installé conformément aux normes électriques nationales et locales 경고 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다 Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要が あります 警告 本产品的废弃处理应根据所有国家的法律和规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規...

Страница 38: ...nvironnement Renseignez vous auprès de l organisme compétent Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Hot Swap Fan Warning המוצר סילוק אזהרה ו להנחיות בהתאם להיות חייב זה מוצר של סופי סילוק המדינה חוקי ﺍﻟﻨﻬﺎﺋﻲ ﺍﻟﺘﺨﻠﺺ ﻣﻦ ﺍﻟﻤﻨﺘﺞ ﻫﺬﺍ ﻣﻌﻪ ﺍﻟﺘﻌﺎﻣﻞ ﻳﻨﺒﻐﻲ ﻟ ﻭﻓﻘ...

Страница 39: ...garde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur אזהרה חלקי את מסירים כאשר יש עובדים עדיין והמאווררים יתכן מהמארז המאוורר להרחיק ל המאוורר בתוך מהפתחים שונים עבודה וכלי האצבעות את בטוח מרחק ﺍﻟﻤﻤﻜﻦ ﻣﻦ ﺍﻟﻤﺮﺍﻭﺡ ﺃﻥ ﺗﺰﺍﻝ ﻻ ﺇﺯﺍﻟﺔ ﺗﺪﻭﺭﻋﻨﺪ ﻛﺘﻠﺔ ﺍﻟﻤﺮﻭﺣﺔ ﺍﻟﻬﻴﻜﻞ ﻣﻦ ﻳﺠﺐ ﺇﺑﻘﺎء ﺍﻷﺻﺎﺑﻊ ﻭ ﺍﻟﺒﺮﺍﻏﻲ ﻣﻔﻜﺎﺕ ﺍﻷﺷﻴﺎء ﻣﻦ ﻭﻏﻴﺮﻫﺎ ﺑﻌﻴﺪﺍ ﻋﻦ ﺍﻟﻔﺘﺤﺎﺕ ﻓﻲ ﻛﺘﻠﺔ ﺍﻟﻤﺮﻭﺣﺔ 경고 섀시로부터 팬 조립품...

Страница 40: ...SA auf der Code für alle anderen elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexión previstos o designados los cables y adaptadores de CA La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el uso d...

Страница 41: ...י על צוין שלא ﺗﺮﻛﻴﺐ ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﻳﺠﺐ ﺍﻟﺠﻬﺎﺯ ﻭ ﺍﻟﺘﻮﺻﻴﻞ ﻛﺎﺑﻼﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺍﻟﻜﺎﺑﻼﺕ ﻭﻣﺤﻮﻻﺕ ﺍﻟﻤﺘﺮﺩﺩ ﺍﻟﺘﻴﺎﺭ ﺃﻥ ﺃﻱ ﺍﺳﺘﺨﺪﺍﻡ ﻛﺎﺑﻼﺕ ﻭﻣﺤﻮﻻﺕ ﺃﺧﺮﻯ ﻳﺘﺴﺒﺐ ﻓﻲ ﻋﻄﻞ ﺣﺪﻭﺙ ﺣﺮﻳﻖ ﺃﻭ ﺍﻟﺘﻲ ﻟﻚ ﺗﻮﻓﻴﺮﻫﺎ ﺗﻢ ﺍﻟﻤﻨﺘﺞ ﻣﻊ UL ﺃﻭ CSA ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺍﻷﺟﻬﺰﺓ ﻭﻣﻮﺍﺩ ﻗﺎﻧﻮﻥ ﺍﻟﺴﻼﻣﺔ ﺍﺳﺘﺨﺪﺍﻡ ﻳﺤﻈﺮ ﺍﻟﻜﺎﺑﻼﺕ ﻗﺒﻞ ﻣﻦ ﻣﻌﺘﻤﺪﺓ Supermicro ﺃﺟﻬﺰﺓ ﺃﺧﺮﻯ ﻛﻬﺮﺑﺎﺋﻴﺔ ﻏﻴﺮ ﺍﻟﻤﻨﺘﺠﺎﺕ ﺍﻟﻤﻌﻴﻨﺔ ﻗﺒﻞ ﻣﻦ ﻷﻱ UL CSA ﺗﺤﻤﻞ ﺍﻟﺘﻲ ﻋﻼﻣﺔ 경고 제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블 AC어댑터를 사용...

Страница 42: ...4 20 SUPERSERVER 5038ML H12TRF User s Manual Notes ...

Страница 43: ...and under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent ESD Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modul...

Страница 44: ...s The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back If you need to disconnect any of these cables you should take care to reroute them as they were originally after reconnecting them make sure the red wires connect to the pin 1 locati...

Страница 45: ...s 1 UID Button LED 2 USBs x2 Video Monitor COM UART 3 Dedicated IPMI LAN Port 1 3 2 5 4 I O Ports The I O ports are located at the back of the motherbord node See Figure 5 1 below for the colors and locations of the various I O ports See Section 5 10 for port definitions ...

Страница 46: ...ied multi directional heatsink only Make sure to install the motherboard into the chassis before you install the CPU heatsinks When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to the Supermicro web site for updates on CPU support Installing an L...

Страница 47: ...lign CPU pin 1 the triangle at the bottom left of the CPU against pin 1 of the socket the triangle marker at the bottom left of the CPU socket 5 Once they are aligned carefully lower the CPU straight down into the socket To avoid damaging the CPU or the socket do not drop the CPU on the socket Do not rub the CPU against the surface or against any pins of the socket 6 With the CPU seated inside the...

Страница 48: ...roperly aligned and securely seated inside the socket CPU properly installed Load Plate Handle is locked into place 7 Once the CPU is properly installed use your thumb to gently push the load plat handle down to the handle lock and lock it 8 When the CPU is securely locked into the CPU socket the plastic cap will be automatically loosened from the load plate Use your thumb and index finger to remo...

Страница 49: ...has already been applied 3 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the motherboard and the heatsink bracket underneath 4 Screw in two diagonal facing screws until just snug To avoid possible dam age to the CPU and heatsink do not over tighten the screws 5 Finish the installation by fully tightening all four screws 6 Reverse the order of this p...

Страница 50: ...l more memory if needed See instructions on the next page Memory Support Each X10SLE F supports up to 32GB of Unbuffered UDIMM ECC DDR3 1600 1333 1066 memory in four DIMM slots Only VLP Very Low Profile DIMMs are supported Please refer to the product page on our web site for possible updates to memory support To Install Insert module vertically and press down until it snaps into place Pay attentio...

Страница 51: ...nstalled However for best memory performance install DIMM modules in pairs Recommended Population Balanced DIMMA2 DIMMB2 DIMMA1 DIMMB1 Total System Memory 2GB DIMM 2GB DIMM 4GB 2GB DIMM 2GB DIMM 2GB DIMM 2GB DIMM 8GB 4GB DIMM 4GB DIMM 8GB 4GB DIMM 4GB DIMM 4GB DIMM 4GB DIMM 16GB 8GB DIMM 8GB DIMM 16GB 8GB DIMM 8GB DIMM 8GB DIMM 8GB DIMM 32GB Figure 5 3 Populating DIMM Slots Channel B Slot 2 Blue S...

Страница 52: ... slot clip and remove the PCI slot shield 3 Open the PCI slot clip in the rear of the motherboard node 4 Remove the PCI slot shield 5 The MicroLP module consists of a MicroLP card a riser card and a mounting bracket Simply insert the module into the MicroLP expansion slot 6 Slide the expansion cards bracket into the PCI card slot and fit it with the opening in the rear of the node 7 Close the PCI ...

Страница 53: ... motherboard may vary from those illustrated The figure above shows an exploded view of the module The expansion card riser card and mounting bracket come pre assembled Currently there are three supported MicroLP expansion cards for the 5038ML H12TRF system as described below AOM CGP i2M x2 LAN ports standard AOM CIBF M1M QSFP x2 USB ports optional AOM CTG i1SM SFP x2 USB ports optional Bracket ...

Страница 54: ...TA4 JSD1 JTPM1 JPV1 JWD1 JPME2 JPME1 JPG1 J22 JBT1 SW1 LED5 LED6 JKVM1 JUIDB1 JPWR2 I SATA1 I SATA0 I SATA3 I SATA2 JP16 JP1 JP18 JP17 BAR CODE MAC CODE Battery USB3 0 0 IPMI_LAN UID MICRO LP PCI E 3 0 X8 X10SLE F HF Rev 1 00 PWR DIMMB2 DIMMB1 DIMMA2 DIMMA1 BIOS PCH BMC AST2400 Intel LP C226 C224 CPU ...

Страница 55: ...k Interface JP16 Power Output for Hard Disk Drive 12V and 5V JP17 Motherboard Interface to PDB JP18 Motherboard Interface to PDB JPWR2 SMC Proprietary Power Connector JSD1 SATA DOM Device On Module Power Connector JTPM1 Trusted Platform Module Port 80 Connector I SATA0 I SATA4 Serial ATA Ports I SATA0 3 SATA 3 0 I SATA4 SATA 2 0 Micro LP PCI E Slot SMC Proprietary Micro Low Profile LP PCI Express ...

Страница 56: ...on our website http www supermicro com UID Switch Pin Definition 1 Ground 2 Ground 3 Button In 4 Button In UID LED Status Color State Status Blue On Unit Identified Power Switch LED A power switch LED indicator is located next to the UID button LED on the backplane of the motherboard Use this switch to power on or power off the system IPMI_LAN Port An dedicated IPMI Ethernet port is lo cated on th...

Страница 57: ...een the motherboard and a PDB DOM PWR Connector JSD1 The Disk On Module DOM power con nector located at JSD1 provides 5V Gen1 Gen power to a solid state DOM storage device connected to one of the SATA ports See the table on the right for pin definitions DOM PWR Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground Universal Serial Bus USB A USB 3 0 port USB 0 is located next to I SATA3 to provide ...

Страница 58: ...usted Platform Module Port 80 head er is located at JTPM1 to provide TPM support and Port 80 connection Use this header to enhance system performance and data security See the table on the right for pin definitions TPM Port 80 Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 KEY 5 LRESET 6 5V X 7 LAD 3 8 LAD 2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 RSV0 14 RSV1 15 3V_DUAL 16 ...

Страница 59: ...s either on only one pin or completely removed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power cord s It is also recom mended that you remove the onboard batter...

Страница 60: ...Disabled Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled Manufacturer Mode Select Close this jumper JPME2 to bypass SPI flash security and force the system to use the Manufacturer Mode which allows the user to flash the system firm ware from a host server to modify system settings See the table on the right for jumper settings ME Mode Select Jumper Set...

Страница 61: ...ve Serial ATA SATA I SATA 0 4 ports are provided on the motherboard I SATA0 3 supports SATA 3 0 and I SATA4 supports SATA 2 0 These Serial Link connections provide faster data transmission than legacy Parallel ATA See the table on the right for pin definitions SATA Port Pin Definitions Pin Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SATA_RXN 6 SATA_RXP 7 Ground PWR Fail Fan Fail OH LED Status...

Страница 62: ...referred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown in Figure 5 6 should appear Note Click the icons showing a hand writing on paper t...

Страница 63: ...emperature system voltages and fan status See the figures below for examples of the SuperDoctor III interface Note The default User Name and Password for SuperDoctor III is ADMIN ADMIN Note When SuperDoctor III is first installed it adopts the temperature threshold settings that have been set in BIOS Any subsequent changes to these thresholds must be made within SuperDoctor III as the SuperDoctor ...

Страница 64: ...e Display Screen Remote Control Note The SuperDoctor III program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories soft ware SuperDoctorIII cfm For Linux we recommend that you use the SuperDoctor II application instead ...

Страница 65: ...the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Figure 5 9 Installing the Onboard Battery Please handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulation...

Страница 66: ...ed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory ...

Страница 67: ...ft the top cover up and off the chassis 4 Peel off the protective film covering the top cover and the top of the chassis 5 Check that all ventilation openings on the top cover and the top of the chassis are clear and unobstructed Warning Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overh...

Страница 68: ...s contained in separate nodes Three nodes each share a common fan see figure below Figure 6 2 Corresponding Nodes and Fans Corresponding Nodes and Fans Cooling Zone Node Fans Zone 1 Nodes 1 through 6 Fans 1 2 Zone 2 Nodes 7 through 12 Fans 3 4 Fan 1 Fan 3 Fan 4 Fan 2 Cooling Zone 1 Cooling Zone 2 1 2 3 5 9 6 10 11 12 7 8 4 ...

Страница 69: ...oved from the chassis Removing Nodes from the System 1 Power down the individual node by pressing that node s power button 2 Press and hold down the release tab on the back of the node 3 Use the node s handle to pull the node from the system Warning Except for short periods of time while swapping nodes do not operate the server with the node bays empty In the unlikely event of a node failure remov...

Страница 70: ...03 0N bracket Installing Removing Hard Drives from the Sled 1 Remove the node to have HDDs installed or removed by following the proce dure in the previous section 2 Place the sled on a flat non conductive surface 3 Insert the hard drive with the printed circuit board side facing downward so that the mounting holes in the drive align with those in the bottom of the sled 4 Secure the hard drive to ...

Страница 71: ...nstalling Removing 2 5 Hard Drives Optional Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro Web site at http www supermicro com products nfo storage cfm ...

Страница 72: ...ssis In the event of a fan failure follow the instructions below to replace it Removing a Fan 1 Visually inspect the fans to see which one has failed 2 Push both release tabs on the failed fan inward 3 Remove the the fan from the chassis The wiring will disconnect automati cally 4 Remove the screws securing the fan ti its housing and set them aside for later use 5 Insert a new fan into the housing...

Страница 73: ...f the power supplies needs to be replaced one power supply can be removed without powering down the system Replacement power supply units may be ordered directly from Supermicro Changing the Power Supply 1 With the system running unplug the AC power cord from the failed power supply module 2 Press the release tab at the top of the power module 3 Push and hold the release tab on the back of the pow...

Страница 74: ...ons that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note the AMI BIOS has default text messages built in Supermicro retains the ...

Страница 75: ...S unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special incidental or consequential dam ages arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boot failure 7 2 Main Setup When yo...

Страница 76: ... Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 The following BIOS items will also be displayed Supermicro X10SLE F HF Version Build Date Memory Information Total Memory This displays the total size of memory available in the syste...

Страница 77: ...uiet Boot This feature selects the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode This feature sets the display mode for the Option ROM Select Keep Current to use the current AddOn ROM display setting Sel...

Страница 78: ...abled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer will allow the system to reboot when it is inactive for more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the system shuts down when the power button is pressed Select 4_Seconds_Override to power off the system after the user presses and holds ...

Страница 79: ...ading Technology Intel VT x Virtualization Technology Intel SMX Safer Mode Extensions Technology 64 bit EIST Enhanceed Intel SpeedstepTechnology Technology CPU C3 State CPU C6 State CPU C7 State L1 Data Cache L1 Code Cache L2 Cache L3 Cache Hyper threading Select Enabled to support Intel Hyper threading Technology to enhance CPU per formance The options are Enabled and Disabled ...

Страница 80: ...zation Technology Available when supported by the CPU Select Enabled to use the Intel Virtualization Technology to allow one platform to run multiple operating systems and applications in independent partitions creat ing multiple virtual systems in one physical computer The options are Enabled and Disabled Hardware Prefetcher Available when supported by the CPU If set to Enabled the hardware prefe...

Страница 81: ... to enter the value Enter 0 to use the manufacture default setting CPU Power Limit1 Time Available when Turbo Mode is set to Enabled This item allows the user to determine how long CPU1 should operate at the power limit set by the user for the item above Use the number keys on your keyboard to enter the value Enter 0 to use the manufacture default setting CPU Power Limit2 Time Available when Turbo...

Страница 82: ...d Use this feature to set the power limit for DDR2 Press or on your keyboard to change this value Enter 0 to use the manufacture default setting 1 Core Ratio Limit Available when Turbo Mode is set to Enabled This feature increases multiplies 1 clock speed in the CPU core in relation to the bus speed when one CPU core is active Press or on your keyboard to change this value Enter 0 to use the manuf...

Страница 83: ... Select Enabled to enable Enhanced C1 Power State to boost system perfor mance The options are Enabled and Disabled CPU C3 Report Available when CPU C States is set to Enabled Select Enabled to allow the BIOS to report the CPU C3 State ACPI C2 to the operating system During the CPU C3 State the CPU clock generator is turned off The options are Enabled and Disabled CPU C6 Report Available when CPU ...

Страница 84: ...quests to C3 based on the information of un cored auto demote The options are Disabled and Enabled C State Pre Wake Select Enabled to enable C State Pre Wake State support The options are Enabled and Disabled Package C State limit Select Auto for the AMI BIOS to automatically set the limit on the register of the C State package The options are C0 C1 C2 C3 C6 C7 C7s and Auto LakeTiny Feature Select...

Страница 85: ...in operation to reduce power consumption Note Please be sure to restore the default settings and save appropriate end point settings for all components associated to this feature before you enable this feature The options are Enabled and Disabled Detect Non Compliance Device Select Enabled for the AMI BIOS to automatically detect a PCI E device that is not compliant with the PCI E standards The op...

Страница 86: ...dge and South Bridge The options are Disabled and Enabled Memory Configuration This submenu displays the information on the memory modules installed on the motherboard Memory RC Version Memory Frequency Total Memory Memory Voltage DIMMA1 DIMMA2 DIMMB1 DIMMB2 CAS Latency tCL Minimum Delay Time CAS to RAS tRODmin Row Precharge tRPmin Active to Precharege tRASmin Memory Frequency Limiter This feature...

Страница 87: ...pport One EHCI controller must always be enabled The settings are Enabled and Disabled EHCI2 Select Enabled to enable EHCI Enhanced Host Controller Interface Controller 2 for USB 2 0 support One EHCI controller must always be enabled The settings are Enabled and Disabled Legacy USB Support Select Enabled to support legacy USB devices Select Auto to disable legacy sup port if legacy USB devices are...

Страница 88: ...in SATA controllers on the motherboard The options are Enabled and Disabled SATA Mode Selection This item selects the mode for the installed SATA drives The options are IDE AHCI and RAID SATA RAID Option ROM UEFI Driver Available if the item above SATA Mode Select is set to AHCI or RAID Select Enabled to use the SATA RAID Option ROM UEFI driver for system boot The options are Enabled and Disabled ...

Страница 89: ...rial ATA Port 0 Port 4 This item displays the information detected on the installed SATA drives on the particular SATA port Model number of drive and capacity Software Preserve Support Port 0 Port 4 Hot Plug This feature designates this port for hot plugging Set this item to Enabled for hot plugging support which will allow the user to replace a SATA drive without shutting down the system The opti...

Страница 90: ...ll allow the user to boot the system using a device installed on the slot specified The options are Disabled Legacy and EFI Launch Storage OPROM Policy This feature controls how the system executes UEFI Unified Extensible Firmware Interface and legacy storage OPROM Select Legacy Only to boot the system using a legacy device installed in a PCI slot The options are UEFI Only and Legacy Only Other PC...

Страница 91: ...abled Intel Server Platform Services The following Intel Server Platform Services configuration settings will be displayed ME Management Engine BIOS Interface Version SPS Version ME FW Firmware Status Value ME FW State ME FW Operation State ME FW Error Code ME NM FW Status Value BIOS Booting Mode Cores Disabled ME FW SKU Information End of POST Status Trusted Computing Configuration Available when...

Страница 92: ...d Status TPM Active Status TPM Owner Status Intel TXT LT Support Intel TXT Trusted Execution Technology helps protect against software based attacks to ensure the security confidentiality and integrity of all data stored in the system The options are Enabled and Disabled Super IO Configuration Super IO Chip NCT6776D Serial Port 1 Configuration Select Enabled to enable the onboard serial port The o...

Страница 93: ...d for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity b...

Страница 94: ...in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST Power On Self Test When ...

Страница 95: ...ter set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec tion Make sure that the same speed is used in the host computer and in the client computer A lower transmission speed may be required for long and busy lines The opti...

Страница 96: ...data stored in the event log will be erased upon next system reboot Select Yes Every Reset data stored in the event log will be erased upon every system reboot The options are No Yes Next reset and Yes Every reset When Log is Full Select Erase Immediately for all messages to be automatically erased from the event log when the event log memory is full The options are Do Nothing and Erase Immediatel...

Страница 97: ...length of time in minute it must pass before a duplicate log event entry is generated Enter a number from 0 to 99 The default value is 60 minutes View SMBIOS Event Log This section displays the contents of the SMBIOS Event Log 7 5 IPMI The following IPMI information will be displayed IPMI Firmware Revision IPMI Status IPMI Firmware Revision This item indicates the IPMI firmware revision used in yo...

Страница 98: ...Yes On every reset When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full Select Erase Immediately to erase all events in the log when the system event log is full The options are Do Nothing and Erase Immediately BMC Network Configuration LAN Channel 1 This feature allows the user to configure the settings for LAN1 Port Update IPMI LAN Con...

Страница 99: ...he following items are assigned IP addresses automatically if DHCP is selected or can be configured manually if Static is selected Station MAC Address This item displays the Station MAC address for this computer Mac addresses are 6 two digit hexadecimal numbers Station IP Address This item displays the Station IP address for this computer This should be in decimal and in dotted quad form i e 192 1...

Страница 100: ...izes the order of bootable devices that the system to boot from Press ENTER on each entry from top to bottom to select devices 1st Boot Device 2nd Boot Device 3rd Boot Device 4th Boot Device 5th Boot Device 6th Boot Device USB Hard Disk Drive BBS Priorities 1st Device 2nd Device Network Device BBS Priorities 1st Device ...

Страница 101: ... feature to remove a pre defined boot device from which the system will boot during startup The settings are any pre defined boot device Add New Driver Option This feature allows the user to add a boot device from which the systems boots during startup Add Driver Option Enter the name of the new boot option here Path for Driver Option Enter the path of the new boot option here Create Press Enter h...

Страница 102: ...ould be from 3 characters to 8 characters long User Password Available when an Administrator Password is set Use this feature to set the User Password which is required to enter the system or the BIOS setup utility The length of the password should be from 3 characters to 8 characters long HDD Security Available when an HDD is detected in the system Use this feature to set the security setting for...

Страница 103: ...nter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS Setup Utility and reboot the computer so the new system con figuration parameters can take effect Select Save Changes and Exit from the Exit menu and press Enter Save Options Save Changes When you have completed the system configuration changes select this option to save any ch...

Страница 104: ... Defaults from the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press En ter Use this feature to retrieve user defined settings that were saved previously Boot Override Listed on this section are other boot options for the system i e Built in EFI sh...

Страница 105: ...7 32 SUPERSERVER 5038ML H12TRF User s Manual Notes ...

Страница 106: ...p If a fatal error oc curs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short...

Страница 107: ...A 2 SUPERSERVER 5038ML H12TRF User s Manual Notes ...

Страница 108: ...ash BIOS Memory Capacity Each node supports up to 32 GB of ECC DDR3 1600 1333 UDIMM Unbuffered VLP Very Low Profile memory total of 384 GB for the system Note See the memory section in Chapter 5 for details Hard Drives Each node can be configured to house 2x 3 5 SATA 3 0 hard drives or four 2 5 SATA 3 0 hard drives with extra MCP 220 93903 0N bracket Expansion Slots Each node supports one MicroLP ...

Страница 109: ... 240V AC auto range Rated Input Current 11 5 5 5A max Rated Input Frequency 50 to 60 Hz Power Supply Rated Output Power 1000W 100 120V 1200W 120 140V 1620W 180 240V Part PWS 1K63S 1R Rated Output Voltages 12V 84A 1000W 100A 1200W 135A 1620W 5Vsb 4A Operating Environment Operating Temperature 10º to 35º C 50º to 95º F Non operating Temperature 40º to 70º C 40º to 158º F Operating Relative Humidity ...

Страница 110: ...2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety EN 60950 IEC 60950 Compliant UL Listed USA CUL Listed Canada TUV Certified Germany CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handli...

Страница 111: ... perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all ...

Отзывы: