background image

SBI-7147R-S4F

Blade Module

User’s Manual

Revison 1.0

Summary of Contents for SBI-7147R-S4F

Page 1: ...SBI 7147R S4F Blade Module User s Manual Revison 1 0 ...

Page 2: ... resolution of any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated i...

Page 3: ...neral overview of safety precautions that should be followed when installing and servicing SBI 7147R S4F blade module Chapter 3 Setup and Installation Refer to this chapter for details on installing the SBI 7147R S4F blade module into the SuperBlade chassis Other sections cover the installation and placement of memory modules and the installation of hard disk drives into the blade module Chapter 4...

Page 4: ...SBI 7147R S4F Blade Module User s Manual iv Notes ...

Page 5: ...4 Power Disconnection Warning 2 5 Equipment Installation 2 6 Restricted Area 2 7 Battery Handling 2 9 Redundant Power Supplies 2 10 Backplane Voltage 2 11 Comply with Local and National Electrical Codes 2 12 Product Disposal 2 13 Hot Swap Fan Warning 2 14 Power Cable and AC Adapter 2 15 Chapter 3 Setup and Installation 3 1 3 1 Overview 3 1 3 2 Installing Blade Modules 3 1 Powering Up a Blade Unit ...

Page 6: ...tware 3 14 3 9 Configuring and Setting up RAID 3 14 Chapter 4 Blade Module Features 4 1 4 1 Control Panel 4 2 Power Button 4 3 KVM Button 4 3 LED Indicators 4 3 KVM Connector 4 3 4 2 Mainboard 4 4 Jumpers 4 6 CMOS Clear 4 6 4 3 Blade Unit Components 4 7 Memory Support 4 8 Hard Disk Drives 4 8 Chapter 5 BIOS 5 1 5 1 Introduction 5 1 System BIOS 5 1 How To Change the Configuration Data 5 1 Starting ...

Page 7: ...vii Table of Contents 5 9 Security 5 18 5 10 Save Exit 5 19 Appendix A AMI UEFI BIOS POST Codes A 1 A 1 Checkpoint Ranges A 1 A 2 Standard Checkpoints A 2 A 3 OEM Reserved Checkpoint Ranges A 9 ...

Page 8: ...SBI 7147R S4F Blade Module User s Manual viii Notes ...

Page 9: ... please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety information http super dev about policies safety_information cfm If you have any questions please contact our support team at support supermicor com Not...

Page 10: ...en 16 240 pin DIMM sockets that can support up to 512 GB RDIMM 128 GB UDIMM or 1 TB LRDIMM DDR3 1866 1600 1333 1066 MHz speed 64GB 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory Memory is interleaved which requires modules of the same size and speed to be installed in groups of two or three Table 1 1 SBI 7147R S4F Blade Module Specification Features Mainboard B9QR7 proprietary form factor Chassis...

Page 11: ...ge 3 1 for storage installation details RAID Each SBI 7147R S4F blade module supports up to four hard drives which may be used with SAS2 drives to create a RAID 0 1 and 10 system Further information on the RAID and its software can be found on our website at http www supermicro com manuals other LSI_2108_2208_SAS_MegaRAID_Configuration_Utility pdf Density A maximum of ten blade modules may be inst...

Page 12: ...cro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 23511 Taiwan R O C Tel 886 2 8226 ...

Page 13: ...e Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning Definition Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing acci...

Page 14: ...ada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez consci...

Page 15: ...n van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい 警告 将此系统连接电源前 请先阅读安装说明 警告 將系統與電源連接前 請先閱讀安裝說明 Warnung Vor dem A...

Page 16: ...dukt ist darauf angewiesen dass im Gebäude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est d...

Page 17: ...m the power supply module s before accessing the chassis interior to install or remove system components 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために シャーシー内部にアクセ スするには システムの電源はすべてのソースから切断され 電源コードは電源モジュールから取り 外す必要があります 警告 在你打开机箱并安装或移除内部器件前 必须将系统完全断电 并移除电源线 警告 在您打開機殼安裝或移除內部元件前 必須將系統完全斷電 並移除電源線 Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein das von den Spg Verso...

Page 18: ... Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment 機器の設置 トレーニングを受け認定された人だけが...

Page 19: ... mag alleen worden geïnstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations アクセス制限区域 このユニットは アクセス制限区域に設置されることを想定しています アクセス制限...

Page 20: ... d accès réservés L accès à une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen ve...

Page 21: ...nutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplacée correctement Ne la remplacer que par une pile de type semblable ou équivalent recommandée par le fabricant Jeter les piles usagées conformément aux instructions du fabricant Advertencia Existe peligro de explosión si la batería se reemplaza de manera incorrecta Reemplazar la batería e...

Page 22: ...ニットは複数の電源装置が接続されている場合があります ユニットの電源を切るためには すべての接続を取り外さなければなりません 警告 此部件连接的电源可能不止一个 必须将所有电源断开才能停止给该部件供电 警告 此裝置連接的電源可能不只一個 必須切斷所有電源才能停止對該裝置的供電 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugeführt wird müssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga más de una conexión para fuentes de alimentación Para cortar ...

Page 23: ...意ください 警告 当系统正在进行时 背板上有很危险的电压或能量 进行维修时务必小心 警告 當系統正在進行時 背板上有危險的電壓或能量 進行維修時務必小心 Warnung Wenn das System in Betrieb ist treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensio...

Page 24: ...取り付けはその地方および国の電気規格に準拠する必要があります 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L équipement doit être installé conformément aux normes électriques nationales et locales ھﻨﺎك ﺧﻄﺮ ﻣﻦ اﻟﻜﮭﺮﺑﺎﺋﻲ اﻟﺘﯿﺎر ﻋﻠﻰ اﻟﻤﻮﺟﻮدة أواﻟ...

Page 25: ...规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et ou directives de respect de l environnement Renseignez vous...

Page 26: ...轉動 小心不要將手指 螺絲起子和其他物品 太靠近風扇 Warnung Die Lüfter drehen sich u U noch wenn die Lüfterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de l...

Page 27: ... fire Electrical Appliance and Material Safety Law prohibits the use of UL or CSA certified cables that have UL CSA shown on the code for any other electrical devices than products designated by Supermicro only 電源コードと AC アダプター 製品を設置する場合 提供または指定された接続ケーブル 電源コードと AC アダプ ターを使用下さい 他のケーブルやアダプタを使用すると故障や火災の原因になるこ とがあります 電気用品安全法は UL または CSA 認定のケーブル UL CSE マークが コードに表記 を Supermicro が指定する製品以外に使用することを禁止しています 警...

Page 28: ...lamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou désigné L utilisation d autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie Appareils électroménagers et de loi sur la sécurité Matériel interdit l utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que ...

Page 29: ...인증한 케이블 전선 위에 UL CSA 가 표시 들의 사용을 금지합니다 Waarschuwing Bij het installeren van het product gebruik de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektr...

Page 30: ...SBI 7147R S4F Blade Module User s Manual 2 18 Notes ...

Page 31: ...d off independently from the rest of the blades installed in the same enclosure A blade unit may be powered up in two ways Press the power button on the blade unit Use IPMIView or the web browser based management utility to apply power using the CMM module Powering Down a Blade Unit A blade unit may be powered down in either of the following ways Press the power button on the blade unit Use IPMIVi...

Page 32: ...Enclosure above 2 Depress the two buttons on the cover while pushing the cover toward the rear of the blade unit When it stops lift the cover off the blade unit 3 To replace the cover fit the six grooves in the cover into the studs in the sides of the blade then slide the cover toward the front of the blade to lock it into place Installing a Blade Unit into the Enclosure Make sure the cover of the...

Page 33: ...3 3 Chapter 3 Setup and Installation Figure 3 1 Inserting a Blade into the Enclosure Figure 3 2 Locking the Blade into Position ...

Page 34: ...ng comes into contact with the thermal grease on its underside 5 Raise the lever of the processor socket up until the processor is released from the socket then lift the silver cover plate and remove the processor 6 Reapply plastic socket covers to the LGA2011 sockets to prevent pin damage Installing a Processor Caution This action should only be performed by a trained service technician Caution W...

Page 35: ... Press the second load lever labeled Close 1st to release the load plate that covers the CPU socket from its locking position Figure 3 4 Figure 3 3 Open First Load Lever Figure 3 4 Close First Load Lever OPEN1st OPEN1st WARNING WARNING Press down on Load Lever labeled Open OPEN1st OPEN1st WARNING WARNING OPEN1st OPEN1st WARNING WARNING OPEN1st OPEN1st WARNING WARNING Press down on Load the Lever l...

Page 36: ...en the load plate Lift the load plate to open it completely Figure 3 5 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket Figure 3 6 Figure 3 5 Opening the Load Plate Figure 3 6 Removing the Warning Plastic Cap OPEN1st OPEN1st WARNING WARNING WARNING WARNING Gently push down to pop the load plate WARNING ...

Page 37: ...ny pins of the socket to avoid damaging the CPU or the socket Caution You can only install the CPU inside the socket in one direction Make sure that the CPU is properly inserted into the CPU socket before closing the load plate If it doesn t close properly do not force it as it may damage your CPU Instead open the load plate again and double check that the CPU is aligned properly 7 With the CPU in...

Page 38: ...e lever labeled Open 1st second Figure 3 11 Use your thumb to gently push the load levers down to the lever locks Figure 3 9 Closing the Load Plate Figure 3 10 Locking the Close First Lever Figure 3 11 Locking the Open 1st Lever OPEN1st OPEN1st Push down and lock the level labeled Close 1st OPEN1st OPEN1st OPEN1st OPEN1st Push down and lock the lever labeled Open 1st Lever ...

Page 39: ...uper Micro authorized manufacturer due to compatibility issues See details below on supported memory and our web site www supermicro com products superblade for recommended memory Populating Memory Slots The mainboard of a SBI 7147R S4F blade module has sixteen 16 memory slots four for each processor Both interleaved and non interleaved memory are supported so you may populate any number of DIMM s...

Page 40: ...ets of four 4 DIMMs for the CPU s Table 3 1 Populating Eight Memory Slots for Interleaved Operation of DIMMs CPU1 CPU2 CPU3 CPU4 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 4 X X X X 8 X X X X X X X X 12 X X X X X X X X X X X X 16 X X X X X X X X X X X X X X X X Figure 3 13 16 slot DIMM Numbering P1 DIMMB1 CPU1 CPU...

Page 41: ...module to prevent inserting the DIMM incorrectly see Figure 3 14 5 Gently press down on the DIMM until it snaps into place in the slot Repeat for all modules see Table 3 1 for installing DIMMs into the slots in the correct order 6 Replace the air shroud and the blade cover and install the blade module back into the enclosure 7 Power up the blade unit see Powering Up a Blade Unit on page 3 1 Figure...

Page 42: ...a hard drive use the following procedure Installing a Hard Drive 1 Remove a blank drive carrier from the blade see removal procedure above 2 Insert a drive into the carrier with the PCB side facing down and the connector end toward the rear of the carrier 3 Align the drive in the carrier so that the screw holes of both line up Note that there are holes in the carrier marked SATA to aid in correct ...

Page 43: ...onnect a monitor to the video connector on the SUV cable Turn on the blade module 3 Insert the CD containing the OS into the CD ROM drive 4 Follow the prompts to begin the installation Installing via PXE Boot PXE Preboot Execution Environment is used to boot a computer over a network To install the OS via PXE the following conditions must be met 1 The PXE BOOT option in BIOS must be enabled 2 A PX...

Page 44: ...ensive set of functions and monitored data to keep tabs on the system and perform management activities Refer to the manuals on your SuperBlade CD ROM for further details on the various functions provided by these management programs 3 9 Configuring and Setting up RAID Each blade module that supports two or more hard drives may be used to create a RAID array The procedures for doing this vary depe...

Page 45: ...Description Processors Supports single or dual 2011 pin Socket R LGA 2011 E5 4600 V2 series processors Memory Supports up to 512 GB of RDIMM and 128 GB of UDIMM DDR3 1866 1600 1333 1066 MHz speed 64GB 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory in sixteen 16 240 pin DIMM sockets Storage Up to four hot plug 2 5 hot pluggable enterprise SATA SAS2 SSD drives Ports KVM port 1 SATA port 1 Features ...

Page 46: ...rns blade module on and off 2 KVM Button N A Initiates KVM function 3 Power LED Green Indicates power status On Orange Indicates power status Off with power cables plugged in 4 KVM UID LED Blue Indicates KVM being utilized on blade unit Flashing Blue Indicates UID activated on blade module 5 Network IB LED Flashing Green Indicates network activity over LAN Flashing Orange Indicates network activit...

Page 47: ...nother blade disconnect the cable then reconnect it to the new blade See the Web based Management Utility User s Manual on your SuperBlade system CD ROM for further details on using the KVM function remotely Table 4 3 Blade Module LED Indicators LED State Description Power LED Green Power On Amber Standby Red Power Failurea a In the event of a power failure the N 1 Redundant Power Supply if includ...

Page 48: ... unit is a proprietary design which is based on the Intel C602J chipset See Figure 4 4 for a block diagram of this chipset Figure 4 3 for a view of the B9QR7 mainboard and Figure 4 5 for an exploded view diagram of the blade unit Figure 4 3 B9QR7 Mainboard 4 4 3 3 3 3 3 3 3 3 1 1 1 1 2 2 6 10 7 5 9 8 ...

Page 49: ...ip DDR3 DIMMH1 DDR3 DIMMG1 SATA PORT0 6G S CPU REAR CPU2 DDR3 DIMMF1 DDR3 DIMME1 QPI SYSTEM BIOS DDR3 DIMML1 DDR3 DIMMK1 CPU FRONT CPU3 DDR3 DIMMJ1 DDR3 DIMMI1 QPI GEN3 x8 nvSRAM Flash DDR II JKTPM1 TPM header PCI DDR3 DIMMP1 DDR3 DIMMO1 CPU FRONT CPU4 DDR3 DIMMD1 DDR3 DIMMC1 CPU REAR CPU1 DDR3 DIMMB1 DDR3 DIMMA1 GEN2 x4 GEN3 x8 i350 Ethernet Chip QPI DDR3 DIMMN1 DDR3 DIMMM1 Intel C602J Chipset DM...

Page 50: ...nd will also clear any passwords JBT1 consists of two contact pads located near the BIOS chip Clearing CMOS 1 First power down the blade and remove it from the enclosure 2 Remove the blade cover to access the mainboard see Removing Replacing the Blade Cover on page 3 2 for further details Short the CMOS pads with a metal object such as a small screwdriver 3 Replace the cover install the blade back...

Page 51: ...re 4 5 Exploded View of a SBI 7147R S4F Blade Module Table 4 5 Main Components of a SBI 7147R S4F Blade Module Item Description 1 Blade Unit Module 2 2 5 Hard Drives four 3 CPUs Heatsinks 2 4 DIMM slots 16 5 Top Cover 6 KVM Front Panel Module 1 2 5 6 3 2 3 4 4 3 3 4 4 ...

Page 52: ...e hot swapped and removed or replaced without powering down the blade unit they reside in The four drives can be used to set up a RAID array RAID 0 1 and 10 These drives use a blue color for the Blade HDD active LED See Chapter 1 for information on RAID Setup For RAID setup see http www supermicro com support manuals under RAID Installation Guides for details Caution To maintain proper airflow bot...

Page 53: ...little electrical power When the blade unit is turned off a backup battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the blade is powered on it is configured with the values stored in the BIOS ROM by the system BIOS which gains control at boot up How To Change the Configuration Data The CMOS information that determines the system parameters may be chan...

Page 54: ... included with the system 1 Copy the contents of the zip file to a bootable USB pen drive 2 Connect the KVM dongle CBL 0218L to the KVM connector at the front of the blade you will be flashing the BIOS to 3 Connect your bootable USB pen drive to one of the two USB slots on the KVM dongle 4 Boot to the USB pen drive and go to the directory where you saved the contents of the zip file 5 Type flash f...

Page 55: ... ROM file name such as B8DTE142 rom for example in the command 5 3 Running Setup Note Default settings are in bold text unless otherwise noted The BIOS setup options described in this section are selected by choosing the appropriate text from the MAIN BIOS SETUP screen All displayed text is described in this section although the screen display is often all you need to understand how to set the opt...

Page 56: ... LEFT RIGHT arrow keys to change the options for each setting Press the ESC key to exit the CMOS SETUP menu The next section describes in detail how to navigate through the menus Items that use sub menus are indicated with the icon With the item highlighted press the ENTER key to access the sub menu Menu options found in the MAIN BIOS SETUP menu are described in Table 5 1 Figure 5 1 BIOS Setup Scr...

Page 57: ...e correct data for the system date Press the Enter key to save the data System Time To set the system date and time key in the correct information in the appropriate fields Then press the Enter key to save the data BIOS Information BIOS static display information including the motherboard number SMC version SMC Build Date and Total Memory is also shown on the screen ...

Page 58: ...is sub menu Super IO Configuration See Table 5 9 for a description of BIOS setup menu options in this sub menu Serial Port Console Redirection See Table 5 10 for a description of BIOS setup menu options in this sub menu ACPI Settings See Table 5 11 for a description of BIOS setup menu options in this sub menu Trusted Computing See Table 5 12 for a description of BIOS setup menu options in this sub...

Page 59: ...g is Enabled for Windows XP and Linux OS optimized for Hyper threading technology and Disabled for other OSes any OS not optimized for Hyper threading techology When Disabled only one thread per enabled core is enabled Active Processor Cores This setting selects the number of cores to enable in each processor package Options include All 1 2 4 and 6 Limit CPUID Maximum This setting is disabled for ...

Page 60: ...nabled C1E Support Enabled CPU C3 Report Disabled CPU C6 Report Enabled CPU C7 Report Enabled Package C state Limit C6 Energy Performance Long Duration Power Limit Long Duration Maintained Short Duration Power Limit Energy Performance This option allows you to optimize between power and energy savings Windows 2008 and later OSes overides this value according to its power plan Options include Perfo...

Page 61: ... allows you to Enable or Disable Meseg in your system QPI Link Speed Mode This setting allows you to select QPI Link Speed as being either Fast or Slow mode QPI Link Frequency Select This setting allows you to select the QPI link frequency Options include Auto 6 4 GT s 7 2 GT s or 8 0 GT s QPI Link0s This setting allows you to Enable or Disable Link0s in your system QPI Link0p This setting allows ...

Page 62: ...oller 1 2 Legacy USB Support This setting allows you to enable the use of Legacy USB devices If this option is set to Auto legacy USB support will be automatically enabled if a legacy USB device is installed on the mainboard and disabled if no USB devices are connected The options include Disabled Enabled and Auto Port 60 64 Emulation This setting Enables or Disables I O port 60h 64h emulation sup...

Page 63: ...CI device to generate a SERR Maximum Payload Use this setting to set the maximum payload of the PCI Express device or allow the system BIOS to select the value Options include Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes or 4096 Bytes Maximum Read Request Use this setting to set the maximum read request size of the PCI Express device or allow the system BIOS to select the value Options...

Page 64: ...al setting for the Super IO device to use for the Serial Port Options include Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 12 IO 2F8h IRQ 3 12 IO 3E8h IRQ 3 12 and IO 2E8h IRQ 3 12 Device Mode This setting allows you to set the Serial Port Mode to either Normal or High Speed Serial Port 2 Attribute This setting selects the serial port 2 mode between SOL or COM Table 5 10 Serial Port Console Redirection Sub me...

Page 65: ...80x24 or 80x25 Putty KeyPad This setting allows you to select the funtion key and KeyPad to use on the Putty keyboard Options include VT100 LINUX XTERMR6 SCO ESCN or VT400 COM2 Console Redirection Use this setting to Enable or Disable Console Redirection for the COM2 port Console Redirection Settings This sub menu contains Console Redirection settings for the COM2 port Terminal Type This setting a...

Page 66: ...ings This sub menu contains Console Redirection settings for Out of Band Management Windows Emergency Management Services EMS Static display information for Data Bits Parity and Stop Bits is also shown in this sub menu It is only enabled if the above Console Redirection setting is enabled Out of Band Mgmt Port Microsoft Windows Emergency Managment Services EMS allows for remote managment of a Wind...

Page 67: ...ion Technology Configuration using the TXT Support setting TXT Support TXT requires a properly configured TPM LT SX enabled CPU and dependencies listed under this setting Options include Enabled or Disabled Table 5 13 ME Subsystem Sub menu Menu Option Description Intel ME Subsystem Configuration This static information displays the ME BIOS Interface Version and the ME Version for your system ME Su...

Page 68: ... logging of system boot events MECI This setting Multiple Event Count Increment is used to select the number of occurrences of a duplicate event that must pass before the multiple event counter associated with the log entry is updated This is specified as a numeric value in the range of 1 to 255 The default for this setting is set to 1 METW This setting Multiple Event Time Window is used to select...

Page 69: ... choose options for reactions to a full SEL Options include Do Nothing and Erase Immediately Log EFI Status Codes Use this setting to Enable or Disable logging of EFI status codes log only error codes or only progress codes BMC Network Configuration Use this sub menu to configure BMC network parameters BMC Network Configuration Information The sub menu contains static display information for the S...

Page 70: ...he sequence of priority for the boot device such as hard disk drives USB devices CD ROM drives Network drives and so on The menu options are for 1st Boot Device 2nd Boot Device and 3rd Boot device Each numbered boot device can be set to a specific device installed in your system or to Disabled NOTE A device enclosed in parenthesis has been disabled in the corresponding type menu Device Boot Priori...

Page 71: ...and implement the changes you have made to the BIOS Setup Save Changes Highlight this item and hit ENTER to save changes done so far to any of the setup options Discard Changes Highlight this item and hit ENTER to discard cancel any changes you made You will remain in the Setup utility Restore Optimized Defaults Highlight this item and hit ENTER to load the default settings for all items in the BI...

Page 72: ...SBI 7147R S4F Blade Module User s Manual 5 20 Notes ...

Page 73: ...indicate the task the system is currently executing Checkpoints are very useful in aiding software developers or technicians in debugging problems that occur during the pre boot process A 1 Checkpoint Ranges Table A 1 Checkpoint Ranges Status Code Range Description 0x01 0x0B SEC execution 0x0C 0x0F SEC errors 0x10 0x2F PEI execution up to and including memory detection 0x30 0x4F PEI execution afte...

Page 74: ...after microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization 0x0C 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not loaded Table A 3 PEI Phase Status Codes Description Progress Codes 0x10 PEI Core is started 0x11 Pre memory CPU initialization is started 0x12 Pre memory CPU initialization CPU module specific 0x13 Pre memory...

Page 75: ...nitialization 0x35 CPU post memory initialization Boot Strap Processor BSP selection 0x36 CPU post memory initialization System Management Mode SMM initialization 0x37 Post Memory North Bridge initialization is started 0x38 Post Memory North Bridge initialization North Bridge module specific 0x39 Post Memory North Bridge initialization North Bridge module specific 0x3A Post Memory North Bridge ini...

Page 76: ... 0xE1 S3 Boot Script execution 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 0xE7 Reserved for future AMI progress codes S3 Resume Error Codes 0xE8 S3 Resume Failed 0xE9 S3 Resume PPI not Found 0xEA S3 Resume Boot Script Error 0xEB S3 OS Wake Error 0xEC 0xEF Reserved for future AMI error codes Recovery Progress Codes 0xF0 Recovery condition triggered by firmware Auto recovery 0xF1 Recovery co...

Page 77: ...me Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU module specific 0x68 PCI host bridge initialization 0x69 North Bridge DXE initialization is started 0x6A North Bridge DXE SMM initialization is started 0x6B North Bridge DXE...

Page 78: ... 0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is started 0x93 PCI Bus Hot Plug Controller Initialization 0x94 PCI Bus Enumeration 0x95 PCI Bus Request Resources 0x96 PCI Bus Assign Resources 0x97 Console Output devices connect 0...

Page 79: ...3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI re...

Page 80: ...t be met Table A 7 ACPI ASL Checkpoints Status Codes Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sleep state 0x30 System is waking up from the S3 sleep...

Page 81: ...Ranges Status Codes Description 0x05 OEM SEC initialization before microcode loading 0x0A OEM SEC initialization after microcode loading 0x1D 0x2A OEM pre memory initialization codes 0x3F 0x4E OEM PEI post memory initialization codes 0x80 0x8F OEM DXE initialization codes 0xC0 0xCF OEM BDS initialization codes ...

Page 82: ...SBI 7127R SH Blade Module User s Manual A 10 Notes ...

Page 83: ...pected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions lit...

Page 84: ...SBI 7147R S4F Blade Module User s Manual 0 2 SBI 7147R S4F ...

Reviews: