background image

Z-Wave Curtain Motor Controller SR-ZV9080A-B

Safety & Warnings

• 

DO NOT install with power applied to device.

• 

DO NOT expose the device to moisture.

Quick Start 

How to install: 

• 

Step 1: power on the Z-Wave curtain motor controller.

• 

Step 2: activate inclusion mode on your Z-Wave controller.

• 

Step 3: activate inclusion mode of the curtain motor controller by triple press the network 

inclusion/exclusion button. The curtain motor controller will be included to Z-Wave network.

Product Description

The curtain motor controller is a universal, Z-Wave Plus compatible, electric motor controller. The device 
allows for controlling motors of roller blinds and venetian blinds, which are single phase AC powered. The 
curtain motor controller allows for precise positioning of a roller blind or venetian blind slats. Precise 
positioning is available for the motors equipped with mechanic and electronic end switches. The device 
also allows for controlling on/off of lights. The module may be controlled wirelessly, through the Z-Wave 
network primary controller, or through the switch keys connected to it. In addition, the curtain motor 
controller is equipped with Power Metering and over current protection.

The curtain motor controller can be included and operated in any Z-Wave network with other Z-Wave 
certified devices from other manufacturers and/or other applications. All non-battery operated nodes 
within the network will act as repeaters regardless of vendor to increase reliability of the network. 

Calibration button

AC power input 

Network inclusion/
exclusion button

Load output

Switch input

Function Introduction

Ratings:120V~,60Hz,MAX:4A(     )

FCC ID:XXXSR9080A

K1

K2

L

Q1

N

N

AC 100-240V

S

2

Curtain Motor

SR-ZV9080A-B(908.42MHz)

Made in China

S

1

Q2

Controller

MAX:2A (           )

/

1

Summary of Contents for SR-ZV9080A-B

Page 1: ...netian blind slats Precise positioning is available for the motors equipped with mechanic and electronic end switches The device also allows for controlling on off of lights The module may be controlled wirelessly through the Z Wave network primary controller or through the switch keys connected to it In addition the curtain motor controller is equipped with Power Metering and over current protect...

Page 2: ...ary or toggle switches and by dedicated roller blind control switches Connected motor s current and historical power consumption measured Over current protection To be installed in wall switch boxes of dimensions allowing for installation conforming to provisions of applicable regulations The curtain motor controller supports OTA and can update firmware wirelessly Installation Guide Please read ca...

Page 3: ...s 0 light mode either S1 or S2 can control both Q1 and Q2 short pressing or holding down will be recognized automatically For detailed configuration please refer to configuration parameter 7 Note when configured as light mode endpoint 1 reflects to relay 1 Q1 endpoint 2 reflects to relay 2 Q2 2 When parameter 3 value is configured as 1 shutter mode without positioning S1 and S2 are only valid whil...

Page 4: ...ibute supported by switch S1 and S2 are as follows Default configuration of CENTRAL_SCENE_CONFIGURATION_SET is Slow Refresh 1 send Key Held Down every 55s when the switch is pressed and held down Association Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device n...

Page 5: ...curtain motor controller is set to inclusion exclusion mode again it will send out Node Information Frame there are 2 kinds of operation as follows 1 triple press the K2 button the curtain motor controller will be set to inclusion exclusion mode then send out Node Information Frame 2 When the curtain motor controller is under inclusion mode there are two kinds of operation 1 Triple press K2 button...

Page 6: ...lave AOS SUPPORTED COMMAND CLASS Node Info COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SECURITY V2 V2 V1 V1 Endpoint 1 device type GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL Endpoint 2 device type GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Root Device Command List Support S2 S0 COMMAND_CLASS_SUPERVISI...

Page 7: ... 2 Command List Support S2 S0 COMMAND_CLASS_SUPERVISION V1 COMMAND_CLASS_SWITCH_BINARY V1 YES COMMAND_CLASS_ASSOCIATION V2 YES COMMAND_CLASS_ASSOCIATION_GRP_INFO V1 YES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION V3 YES COMMAND_CLASS_SCENE_ACTIVATION V1 YES COMMAND_CLASS_SCENE_ACTUATOR_CONF V1 YES COMMAND_CLASS_SCENE_ACTIVATION V1 YES COMMAND_CLASS_SCENE_ACTUATOR_CONF V1 YES COMMAND_CLASS_MULTI_CHANNE...

Page 8: ...es both 0 and 99 When the working mode is configured as light mode as long as the state changes the state change percentage threshold will be reported SWITCH_MULTILEVEL_REPORT 0 disable to report actively 1 10 value to report unit is one percent 0x02 2 1 1 Enable disable over current protection 0 disable 1 enable when over current detected there are two methods to cancel alarm 1 short press either...

Page 9: ... switch OFF Q2 When S1 short pressed not processed Press and hold down S2 to switch ON Q2 then release to switch OFF Q2 When S2 short pressed not processed Value 3 Short press S1 or S2 to switch ON OFF of both Q1 and Q2 simultaneously When S1 or S2 pressed and held down not processed Value 4 Press and hold down S1 to switch ON Q1 and Q2 When S1 short pressed not processed Press and hold down S2 to...

Page 10: ...shold function 1 10 value of the current change absolute threshold if current change value is over the threshold value report the current change value using METER_REPORT 0x0B 11 0x0C 12 Voltage change absolute threshold unit is 1V 0 disable absolute threshold function 1 10 value of the voltage change absolute threshold if voltage change value is over the threshold value report the voltage change v...

Page 11: ...own and slats rotation K2 inclusion exclusion button used to add or remove a device from the system Compatible Load Types Supported load types 100 240V Lamp and resistive loads Inductive loads Max 4A Max 2A Capacitive loads Max 2A 1 15 1 5S 0x0d 13 Slats rotation time unit is 0 1S 0 disable the function 5 250 0 5S 25S value of the slats rotation time This parameter is only valid when parameter 3 i...

Page 12: ...100 240V S 2 Curtain Motor SR ZV9080A B 908 42MHz Made in China S 1 Q2 Controller MAX 2A S2 S1 1 Curtain Motor Connection Diagram DOWN UP Neutral Live Ratings 120V 60Hz MAX 4A FCC ID XXXSR9080A K1 K2 L Q1 N N AC 100 240V S 2 Curtain Motor SR ZV9080A B 908 42MHz Made in China S 1 Q2 Controller MAX 2A S2 S1 12 ...