Light Weight  

Carbon Fiber Calipers

No. 5001B Series

User’s Guide

INTRODUCTION

This Starrett product is designed for ease 
of use and provides the ability to output 
measurements to a variety of peripherals, 
either through a traditional wire or by 
connecting to a Starrett DataSure

®

 

Wireless Data Collection System End Node.

Changing Battery

If a “B” is displayed on the left side of the 
display, the battery needs to be changed.  
Remove cartridge and replace with Lithium 
3V CR2032 battery.  Changing the battery 
will automatically reset the indicator to 
factory defaults.

To remove the catridge, slide the battery 
carrier (2) in the direction of the arrow 
in Fig. 1.  Remove the battery from the 
carrier and replace it with a fresh CR2032 
battery.  Then, slide the carrier back into 
the housing.

OPERATING INSTRUCTIONS

Button Functions

MODE

 and 

SET

 button operations are: 

Press and Release and Press and Hold

ON / OFF

To turn gage 

ON

Press and Release 

ON/OFF

To turn gage 

OFF

Press and Hold 

ON/OFF

(Note: When the tool is turned on it will 
remain in whichever mode it was in when 
it was turned off.)

Fig. 1

2

1

3

Summary of Contents for 5001B Series

Page 1: ... replace with Lithium 3V CR2032 battery Changing the battery will automatically reset the indicator to factory defaults To remove the catridge slide the battery carrier 2 in the direction of the arrow in Fig 1 Remove the battery from the carrier and replace it with a fresh CR2032 battery Then slide the carrier back into the housing OPERATING INSTRUCTIONS Button Functions MODE and SET button operat...

Page 2: ...de There are 5 Modes available SET REF I REF II PRESET MIN MAX and TOLERANCE To change between Modes Press and Hold MODE Set Mode Set Mode can calibrate zero the tool to a Preset Reference Value see Reference Mode and to change the units of mea sure Note If measurements are to be taken from this mode the Hold function is not available and when the SET key also used as ZERO and HOLD is pressed the ...

Page 3: ... Values NOTE The recalled value depends on the REF MODE the tool is in Press and Hold MODE until INCH MM and SET appears Place the gage into the Gage Master Press and Release SET To go back to the Measurement Mode Press and Hold MODE until REF I or II appears MEASUREMENTS CAN NOW BE TAKEN ZERO RECALL Used to calibrate the gage to zero provided REF I or REF II preset value has been set to 0000 zero...

Page 4: ...il TOL appears To exit Tolerance Setting Mode Press and Hold MODE MEASUREMENTS CAN NOW BE TAKEN Measuring in Tolerance Mode To enter TOLERANCE MODE Press and Hold MODE until TOL appears MEASUREMENTS CAN NOW BE TAKEN Hold Used to hold a measurement value on the display Note Hold function is not available when in the Set Modes To Hold the reading Press and Release SET To release Hold Press and Relea...

Reviews: