background image

SAVE THIS MANUAL: KEEP THIS MANUAL FOR  SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, 

OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S 

SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH 

AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER)

OWNER’S MANUAL AND SAFETY INSTRUCTIONS

FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT:  (909) 628 4900 MON-FRI 9AM TO 3PM PST

50’ 1/2” 250W ELECTRIC SEWER SNAKE DRAIN AUGER CLEANER 

ITEM: 45074

Summary of Contents for 45074

Page 1: ...RES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 4900 MON FRI 9AM TO 3PM PST 50 1 2 250W ELECTRIC SEWER SNAKE DRAIN AUGER CLEANER ITEM 45074 ...

Page 2: ...T allow children to handle the product Grounded tools must be plugged into an outlet that is properly installed and grounded in accordance with all codes and ordinances NEVER remove the grounding prong or modify the plug in any way Double insulated tools are equipped with a polarized plug Double insulation eliminates the need for a three wire grounded power cord and grounded power supply system Av...

Page 3: ...t of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained user Maintain power tools check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged have the power tool repaired before use Many ...

Page 4: ... The GFCI indicator light will go out and power to the machineshould cut off 3 WARNING If the light does not go out when the TEST button is depressed Equipment should not be used until proper repairs have been made by a qualified technician 4 To restore power after testing push the reset button WARNING If the machine doesn t start stops while running or if you experience a mild shock DO NOT use th...

Page 5: ... Dimensions L x W x H 23 00 x 17 50 x 36 00 Inches 50 x 1 2 Cable and Universal Slotted 4 piece cutter kit Portable 8 Solid Rubber Tires and 5 steel wheels 13 x 6 Quick Release Belt Driven Drum 250 watt 110 volt forward reverse motor 5 GCI Power Cord with 3 pronged ground 4 Air operated foot switch 60 HZ 2 7 amp 1400 rpm electric motor Measures 36 tall 30 without handle x 17 5 wide x 23 deep 1 Squ...

Page 6: ...s cleaned Once the drain is flowing more appropriate tools can be used on the rest of the blockage Keep in mind that the largest tool used should be no bigger than the drain s diameter minus an inch If properly used the drain cleaners and assorted drain cleaner accessories will not damage a drain that is in good condition and properly designed constructed and maintained However if the drain is in ...

Page 7: ...hed to the drain cleaner 5 Verify the drain cleaner is properly assembled Inspect the machine for broken or damaged parts before every use 6 Make sure switches and handles move smoothly between positions and lock into place and that the bumpers at the bottom of the handle are present and firmly attached 7 Rotate the drum and make sure that it turns freely without binding 8 Check that all warning l...

Page 8: ...ucted path from the drain cleaner to the electrical outlet 5 Inspect the drain to be cleaned If possible determine the best access point to the drain the size and length of the drain distance to tank mainlines the nature of the blockage and or presence of drain cleaning chemicals 6 If there are chemicals present in the drain read and adhere to the specific safety measures required to work around t...

Page 9: ...s free of blockage and is turning again slowly feed rotating cutting tool back into the vlockage Do not force the tool through blockage 3 Allow the spinning and cutting to break up and work the blockage CAUTION While working the blockage the tool and cable can get clogged with debris and cuttings from blockage preventing further cleaning The cable tool will then need to be retreived from the drain...

Page 10: ... If the cable become lodged in a narrow part of the drain or in a drain trap put the power feed lever in the NEUTRAL position and allow the cable to try and work itself past the obstruction If the cable still won t pass the obstruction release pressure from the foot switch and use sharp downward thrusts to try and free the cable Once the cable is free put the power feed lever in the down forward p...

Page 11: ... LUBRICATING HOUSING 1 The drain cleaner should be cleaned as needed with hot soapy water and or disinfectants 2 Dry the drain cleaner before storing or using again 3 Once dry thoroughly lubricate with a lightweight machine oil 4 If the drain cleaner drum os removed or changed grease the bearings with general purpose grease WARNING Risk of shock DO NOT allow water to get into the motor or any othe...

Page 12: ...11 TROUBLESOOTING ...

Page 13: ...12 PARTS ...

Page 14: ...T ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial number record month...

Reviews: