manualshive.com logo in svg
background image

MODELS BBR 79-2 & BBR 79-3

INSTRUCTION MANUAL

Distributing, L.L.C.

BBR 79-3

BBR 79-2

472 South Mill Street,  Alamo TN 38001

SALES: 

800-851-8180                     

FAX: 

618-993-5960

http://www.southern-pride.com   -   [email protected]  -  [email protected]

SERVICE:

800-437-2679  -

SERVICE FAX:

618-993-0378  -  [email protected]

(2007-2009)

Содержание BBR 79-2

Страница 1: ...stributing L L C BBR 79 3 BBR 79 2 472 South Mill Street Alamo TN 38001 SALES 800 851 8180 FAX 618 993 5960 http www southern pride com sales sopride com service sopride com SERVICE 800 437 2679 SERVICE FAX 618 993 0378 parts sopride com 2007 2009 ...

Страница 2: ...Proper installation operation cleaning and maintenance are essential for your satisfaction and safe operation KEEP THIS MANUAL FOR REFERENCE TABLE OF CONTENTS Safety Information 3 Diagram of Controls Components 4 Operating Instructions 6 Cleaning Instructions 7 Maintenance Schedule 7 Electrical Instructions 8 Oven Wiring Diagram 9 Items to check before firing Burner 11 Burner Specification Instruc...

Страница 3: ...tion or leave off during operation 6 Gas burners require the services of an experienced mechanic for proper setting and adjustment If the burner does not appear to be operating properly DO NOT ATTEMPT TO ADJUST THE BURNER YOURSELF but call in a competent serviceman or contact Southern Pride 7 DO NOT allow unqualified personnel to perform service work or adjustments on this unit To do so will VOID ...

Страница 4: ...SOUTHERN PRIDE S BBR 79 2 BBR 79 3 BBQ OVEN 4 1 4 8 6 3 5 7 1 4 8 6 3 5 7 BBR 79 2 BBR 79 3 2 2 ...

Страница 5: ...tion Fan Thermostat and Red Indicator Lamp The Red Indicator Lamp on the Main Power Switch indicates when the switch is ON 3 SLIDING MEAT LOADING DOOR For access to Racks and Pit interior 4 MEAT LOADING DOOR LATCHES Latches apply positive pressure and seal doors 5 FIREBOX DOOR Provides access for loading of wood in the Firebox Chamber 6 CABINET LEGS Provide adjustment for leveling of the unit 7 DR...

Страница 6: ... NEAR THE BURNER OPENING KEEP ALL LOGS AT LEAST 6 INCHES FROM THE BURNER 3 Be sure the Meat Loading Door is secured in the closed position 5 Set the Thermostat to the desired temperature setting 4 Turn the Main Power Switch to the ON position The wood will be ignited and the cooking temperature will be maintained automatically 6 When the meat is cooked turn the Main Power Switch to the off positio...

Страница 7: ...fore opening drain valve Open Drain Valve and drain Grease 3 Remove food racks and clean them thoroughly Racks simply lift out of the brackets 4 Thoroughly clean the complete interior of the pit Use a food service degreaser Spray degreaser on the interior of the pit and allow it to set for 5 10 minutes Rinse thoroughly with a water hose or pressure washer Drain through the Drain Valve WARNING IT I...

Страница 8: ... PROVIDE SUCH A GROUND WARRANTY IS VOID IF UNIT IS CO NNECTED TO ANY VOLTAGE OTHER THAN SPECIFIED ABOVE AND ON NAMEPLATE 1 Electrician must provide the conduit and wire for hookup 2 Power is to be left OFF throughout installation 3 Electrical Service is connected to the Terminal Block in the lower right side of the service compartment 4 If venting or gas connections are to be done later be sure th...

Страница 9: ...9 DIGITAL GAS OVEN WIRING DIAGRAM BBR 79 2 and BBR 79 3 ...

Страница 10: ...10 79 2 79 3 GAS OVEN WIRING DIAGRAM with CV Series Controller ...

Страница 11: ...f valve drip leg and pressure gauge port 3 Gas pipe size MUST be in accordance with the Pipe Capacity Chart in this Manual 4 Gas line MUST be tested for leaks under pressure 5 Gas Line MUST be purged to remove any air in the system 6 Gas line pressure MUST be checked and MUST NOT exceed the maximum pressure specified in the Burner Specifications in this Manual 7 Burner Orifice MUST correlate with ...

Страница 12: ...s Electrical 120 V A C 60 hz 1 ph Orifice Sizes Model BBR 79 2 BBR 79 3 Natural Gas 19 166 L P Gas 37 104 NOTE Orifice and valve setting must correlate with type of gas being supplied Gas Supply Line Pressure Natural 4 5 W C Minimum L P 11 0 W C Minimum 10 5 W C Maximum 13 0 W C Maximum MANIFOLD PRESSURE Natural 3 5 W C L P 10 0 W C GAS VALVE Control Knob must be ON 12 ...

Страница 13: ...should be firmly supported by pipe hooks straps bands or hangers Butt or lap welded pipe should not be bent 4 The Pipe Capacity Chart must be used to determine the size pipe to use from the meter to the Burner 5 TEST PIPING FOR LEAKS Before turning gas under pressure into piping all openings from which gas can escape must be closed Immediately after turning on gas the system should be checked for ...

Страница 14: ...ovisions must be made for adequate air supply for the pit If the pit is to be installed in a sealed room or building utilizing exhaust fans the room must be supplied with a return air system to eliminate negative air pressure in the room or building Return air must be equal to or in excess of the exhausted air 3 Pit must be level for proper grease drainage 4 Minimum spacings to combustible materia...

Страница 15: ...rner Part Motor Switch Relay Gas Burner Part Blower Motor Gas Burner Part Main Power Switch Gas Valve Specify Natural or L P Gas EP Electrode High Voltage Lead Control Module Gas Burner Part Digital Control Optional 10 AMP Solid State Relay Optional 2 Type K Thermocouple Food Rack 12 x 60 BBR 79 3 Food Rack 18 x 60 BBR 79 3 Firebox Door Gasket Food Rack 12 x 42 BBR 79 2 Food Rack 18 x 42 BBR 79 2 ...

Страница 16: ...r variables chosen by the owner and over which Southern Pride has no control The effect of corrosion fire and normal wear on the equipment or component parts is not covered by this warranty This warranty does not apply to damage caused by accident or to damage caused by the negligence of the owner and the employees of the owner or to damage caused by lightning generated electrical current or any o...

Отзывы: