Page 2: ...Solar Royal SR1800 Series Installation Manual 2 8 Table of Contents 1 Introduction 3 1 1 Purpose 3 2 Installation Manual 3 2 1 Pre requisites 3 2 2 Pre installation Tasks 4 2 3 Installation Procedure 4 ...

Page 3: ...ced and then securely snapped into place 1 1 Purpose This document is provided to serve as a guide for installing the Solar Royal SR1800 on composite shingle roofs Installing an attic fan is fairly easy but Solar Royal LLC recommends that if you have not worked on a roof installed something on your roof before or are not familiar with working on a roof that you should hire an insured and bonded pr...

Page 4: ...d also injure the installer Also if the client wishes to have the unit in another color the SR1800 can be painted to match the home and or roof color Once the fan is installed the white film should be removed so that the SR1800 will work properly Please contact Solar Royal regarding painting the unit Please note once the unit has been painted it is now altered and no longer can be returned 2 3 Ins...

Page 5: ...g the Flashing Once the hole as been made trim away shingles as needed to accommodate the metal base flashing so that you have a clean and tight fit Normally if you cut a clean 15 hole we recommend trimming away from the top rows of shingles an additional 1 one inch to allow the base flashing to slip under the top row s of shingles and over the bottom row s Slip the flat metal base under the top r...

Page 6: ... the flashing This is not a requirement just optional 2 3 3 Sealing and Securing the Flashing Once the metal flashing is in place gently lift the lower exposed metal base flashing and apply sealant caulk generously under the side and lower edges but not so much that it oozes out If sealant starts to ooze just wipe off excess before it hardens The bottom part of the flashing will be exposed and sit...

Page 7: ... Configuring the Hood The SR1800 comes with a 36 thermostat wire thermoball attachment This is designed to hang down into your attic make sure it is untapped and or hanging freely down You can adjust the length of the thermostat with a cable tie or tape The Thermoball is designed to allow the fan to run once the temperature is above 80 F 5 If you do not want to utilize the thermostat the unit is d...

Page 8: ...able away from the spinning blade If you want to have your solar panel at an angle remember to take into consideration where and how the hood is placed The SR1800 when placed on the base should be slightly off and not exactly squared with the metal base unit until the unit is turned to the left and clicked into place You will hear a very distinct Click which is the metal clips locking the solar at...