Uninterruptible Power Supplies

The S5KC Modular UPS is scalable from 5 to 20 kVA, 

offering many flexible options by adding a few standard 
modules. Designed to be fully configured, tested and 
shipped in the configuration you need, the S5KC Modular 
UPS also has the ability to be easily upgraded in the 
field to either higher VA ratings (up to 20 kVA maximum), 
longer back-ups time or to add N+x parallel redundancy. 
Configurations can be cost-effectively upgraded keeping 
your S5KC Modular UPS current without a large 
reinvestment in a new system.

The optional N+x redundancy provides a fault-tolerant group
of power modules and controls. The modular design is easy
to upgrade so the UPS can grow with the needs of the
system that is being protected.

Each of the modular components, including 5 kVA power
modules, LCD display, battery modules and system control 
modules, can be hot-swapped making it easy to increase 
power, extend your back-up time or add redundancy while 
still providing power protection to the load.

This fault-tolerant system uses intelligent power and battery
modules which take themselves off-line if there is a problem
without interrupting power to the load. Self-diagnostic
capabilities simplify maintenance and troubleshooting. Each
unit incorporates an internal automatic bypass.

Applications

With multiple standard options in a smaller footprint, 
providing more flexibility for capacity and communication 
both pre- and post-installation, the S5KC delivers the 
power protection needs in applications such as
• Oil and Gas (Pure  OEMs)
• Pharmaceutical
• Automotive
• Food & Beverage

Features

• Module level redundancy provides multiple layers of

protection to ensure your machine has the power it 
needs to run safely with no single point of failure, critical 
loads continue to run on conditioned battery power even 
if a system component malfunctions. 

• An industry leading 0.9 power factor keeps machines

performing flawlessly when running on battery power.

• Superior overload capabilities deliver conditioned power

during temporary power anomalies without unnecessarily
transferring to and from bypass power.

S5KC Modular Series On-Line Uninterruptible Power Systems (UPS)

• Independently controlled maintenance bypass is

designed to provide maximum system availability to
critical equipment by allowing transfer of connected
equipment to an alternate power path. The UPS can
then be turned Off and removed from service with no
interruption of power to connected equipment.

• True on-line double conversion with a large input voltage

range (low line transfer down to 110 Vac) isolates
sensitive equipment from power fluctuations while

minimizing transfers to increase battery life.

• ENERGY STAR® qualified UPS models – UPS products

meeting the EPA’s requirements use an average of 35%
less energy than their standard counterparts.

• To enhance the availability and trouble-free operation,

every pre-configured S5KC UPS arrives standard with
one IS-UNITY-DP communications card installed.
Enabling you to take advantage of the remote monitoring
and diagnostic service available with your system during
your initial standard warranty period.

• Start-up services available, contact your local SolaHD

sales representative for details.

Certifications and Compliances

Listed, 

UPS Equipment

- UL 1778, Fourth Edition 
- CSA C22.2 No. 107.3

• Series S5KCA, S5KCB,S5KCC,S5KCD

- CE (Low Voltage and EMC Directive)
EN62040-1, EN62040-2 EAC - TR CU 004/2011
Safety of Low-Voltage Equipment, TR CU 020/2011

EMC

E179213

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for s3k1000

Page 1: ...r machine has the power it needs to run safely with no single point of failure critical loads continue to run on conditioned battery power even if a system component malfunctions An industry leading 0 9 power factor keeps machines performing flawlessly when running on battery power Superior overload capabilities deliver conditioned power during temporary power anomalies without unnecessarily trans...

Page 2: ...riate please contact our technical support team to aid in selection 5 Select the unit that meets both your immediate requirements and is expandable to your future needs Each chassis will have a Maximum Upgrade capacity The Maximum Upgrade is the highest kVA expansion that particular configuration is capable of without removing any of the battery modules from the original configuration 6 External B...

Page 3: ...91 0 90 0 91 0 Heat dissipation 4208 BTU Hr 5747 BTU Hr 5528 BTU Hr 7965 BTU Hr 4904 BTU Hr 6768 BTU Hr Input Data Nominal input voltage 200 208 220 230 240 Vac Single Phase 200 100 208 120 220 110 230 115 240 120 Vac Single Phase 380 400 415 Vac 3 Phase Not Applicable Input Voltage Range The input voltage range based on the ouput loading refer to User Manual Power Factor Single phase input 0 99 C...

Page 4: ...Bay 5 15 kVA 1PH Xfmr free 200 240 VAC input output S5KC B 16 Bay 5 20 kVA 1PH Xfmr free 200 240 VAC input output S5KC C 12 Bay 5 15 kVA 1PH Xfmr based 200 240 VAC input 200 100 240 120 VAC output S5KC D 16 Bay 5 20 kVA 1PH Xfmr based 200 240 VAC input 200 100 240 120 VAC output S5KC E 10 Bay 5 15 kVA 2PH Xfmr free 200 100 240 120 VAC input output S5KC F 16 Bay 5 20 kVA 2PH Xfmr free 200 100 240 1...

Page 5: ...r restoration of the AC utility mains source Auto Restart Mode After a power outage and complete battery discharge and once AC utility is restored the UPS will automatically restart and resume supplying power to connected equipment This feature is enabled at the factory but can be disabled by the user The user can also program two auto restart delay settings from the LCD Battery capacity level Cou...

Page 6: ... Uninterruptible Power Supplies S5KC A S5KC B Frames Xfmr Free S5KC C S5KC D Frames Xfmr Based S5KC E S5KC F Frames Xfmr Free Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 7: ...t Power Controls and Battery C2 2 Strings CSB UPS 12460 F2 FR D 16 Bay Xfmr Based 1PH cULus Listed GS CE C tick Marked 20A 20 kVA 18 kW C3 3 Strings CSB UPS 12460 F2 FR E 10 Bay Xfmr Free 2PH cULus Listed C4 4 Strings CSB UPS 12460 F2 FR F 16 Bay Xfmr Free 2PH cULus Listed C5 5 Strings CSB UPS 12460 F2 FR C6 6 Strings CSB UPS 12460 F2 FR C7 7 Strings CSB UPS 12460 F2 FR Example 10 Bay 1PH 10 kVA 9...

Page 8: ...R PD2 108 8 2 L6 30R 2 L6 20R PD2 108 9 2 L14 30R PD2 109 9 2 L14 30R PD2 109 A 4 IEC320 C19 4 IEC320 C13 PD2 200 A 4 IEC320 C19 4 IEC320 C13 PD2 200 B 2 IEC320 C19 8 IEC320 C13 PD2 201 B 2 IEC320 C19 8 IEC320 C13 PD2 201 C 12 IEC320 C13 PD2 202 C 12 IEC320 C13 PD2 202 D 2 IEC309 32A 4 IEC320 C13 PD2 204 D 2 IEC309 32A 4 IEC320 C13 PD2 204 C N N C Configuration Notes 1 Every pre configured S5KC UP...

Page 9: ...5 S5KF15ANNC3GNNC 7 1 S5KF15ANRC3GNNC 6 1 20 18 S5KF20ANNC4GNNC 4 0 S5KF20ANRC4GNNC 3 0 Table 19 Basic Recommended Part Numbers scalable for your application needs Back up time 5 minutes minimum at full load with 1 battery string per 5 kVA Configuration Notes 1 Voltage Options Additional Output Voltage Configurations are available Refer to Table 16 and 18 part number configuration template table E...

Page 10: ...internal batteries Optional matching external battery cabinets offer extended battery runtime Use the part number template below to identify the description of any given part number Specifications Mechanical Conducted and Radiated EMC Levels IEC EN AS 62040 2 Class A FCC Part 15 Class A Safety Standards IEC EN AS 62040 1 2008 UL 1778 4th Ed and CSA 22 2 No 107 3 Immunity Standards IEC EN AS 61000 ...

Page 11: ...20R PD2 105 5 2 L5 30R 2 L5 20R 4 5 15 20R PD2 105 G 208 120V 60Hz L L N G 6 4 L6 20R 4 L5 20R PD2 106 6 4 L6 20R 4 L5 20R PD2 106 H 240 120V 60Hz L L N G 7 4 L5 20R 4 5 15 20R PD2 107 7 4 L5 20R 4 5 15 20R PD2 107 J 220 127V 60Hz L L N G 8 2 L6 30R 2 L6 20R PD2 108 8 2 L6 30R 2 L6 20R PD2 108 9 2 L14 30R PD2 109 9 2 L14 30R PD2 109 A 4 IEC320 C19 4 IEC320 C13 PD2 200 A 4 IEC320 C19 4 IEC320 C13 P...

Page 12: ...VA 4 5kW A B C D Chassis S5KCBATMODCU Replacement Battery Note Each kit includes one string 2 modules S5KCBYPDSPMOD Bypass DSP Module S5KCBYPMCUMOD Bypass MCU Module S5KCLCDMOD LCD module S5KCAFLTRKIT Air Filter Kit S5KCAFLTRKIT FD Fine Dust Air Filter Kit S5KCBEZELHMI Metal HMI Bezel with Display Opening and Filter S5KCBEZEL Metal Bezel for Module Bays and Filter Spare Equipment Parts S5KC5KPWRMO...

Page 13: ...KC 3 Year Extended Warranty 3EWPS4K2U700C 3 year extended warranty for S4K2U700C 3EWPS4K2U1000C 3 year extended warranty for S4K2U1000C 3EWPS4K2U1500C 3 year extended warranty for S4K2U1500C 3EWPS4K2U2000C 3 year extended warranty for S4K2U2000C 3EWPS4K2U3000C 3 year extended warranty for S4K2U3000C 3EWPS4K4U6000C 3 year extended warranty for S4K4U6000C 3EWPS4K6U10KC 3 year extended warranty for S...

Page 14: ...bor warranty Please refer to the following information for a menu of start up options and please choose the appropriate start up service required If start up is not ordered and performed please note that this will reduce your warranty period to two years of parts and 90 days labor A separate Preventative Maintenance Only plan is available in addition to the standard Start Up plan Service Programs ...

Page 15: ...Start Up 7x24 SUPS5KCXXMF S5KC Start Up Plus M F 8 5 w 1PM over initial warranty period SUPS5KCXX24 S5KC Start Up Plus 7x24 w 1PM over initial warranty period Basic Service PM not available Catalog Number Equipment MUUS4K06BA0 S4K4U6000C MEUS4KBATBA0 S4K144BATC S4K288BATC MUUS4K10BAO S4K6U10KC Essential Service w 1 PM Catalog Number Equipment MUUS4K06ES1 S4K4U6000C MEUS4KBATES1 S4K144BATC S4K288BA...

Reviews: