background image

KICTIS90BL

 

Libretto di Istruzioni 

Instructions Manual 

Bedienungsanleitung 

Instrukcja Obsugi 

Manual de instrucciones 

Manual de Instruções 

Manuel d’Instructions 

Gebruiksaanwijzing 

Bruksanvisning 

Käyttöohje 

Brugsvejledning 

Bruksanvisning 

     

 

Summary of Contents for KICTIS90BL

Page 1: ...to di Istruzioni Instructions Manual Bedienungsanleitung Instrukcja Obs ugi Manual de instrucciones Manual de Instruções Manuel d Instructions Gebruiksaanwijzing Bruksanvisning Käyttöohje Brugsvejledning Bruksanvisning ...

Page 2: ...SVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 29 CHARAKTERISTIKEN 32 MONTAGE 34 BEDIENUNG 37 WARTUNG 38 SPIS TRE CI UWAGI I SUGESTIE 41 W A CIWO CI TECHNICZNE 44 INSTALACJA 46 U YTKOWANIE 49 KONSERWACJA 50 ÍNDICE CONSEJOS Y SUGERENCIAS 53 CARACTERÍSTICAS 56 INSTALACIÓN 58 USO 61 MANTENIMIENTO 62 ÍNDICE CONSELHOS E SUGESTÕES 65 CARACTERÍSTICAS 68 INSTALAÇÃO 70 UTILIZAÇÃO 73 MANUTENÇÃO 74 IT EN DE PL ES PT...

Page 3: ...98 INNHOLD ANBEFALINGER OG FORSLAG 101 EGENSKAPER 104 INSTALLASJON 106 BRUK 109 VEDLIKEHOLD 110 SISÄLTÖ OHJEET JA SUOSITUKSET 113 MITAT JA OSAT 116 ASENNUS 118 KÄYTTÖ 121 HUOLTO 122 INDHOLD RÅD OG ANVISNINGER 125 APPARATBESKRIVELSE 128 INSTALLATION 130 BRUG 133 VEDLIGEHOLDELSE 134 INNEHÅLL REKOMMENDATIONER OCH TIPS 137 EGENSKAPER 140 INSTALLATION 142 ANVÄNDING 145 UNDERHÅLL 146 FR NL NO FI DK SE ...

Page 4: ...4 4 149 152 154 157 158 161 164 166 169 170 RU SA ...

Page 5: ...flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly w...

Page 6: ...y to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowle...

Page 7: ...heavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring thi...

Page 8: ...EN 2 20 CHARACTERISTICS Dimensions ...

Page 9: ...ion flange ø 150 120 mm 14 1 2 Air Outlet Connector Extension 15 1 Air Outlet Connector 25 Hose clamps not supplied Ref Q ty Installation Components 7 3 1 Air Outlet Connector fixing bracket 11 4 Wall plugs ø 10 12c 2 Screws 2 9 x 7 5 12e 4 Screws 2 9 x 12 7 12i 2 Screws 2 9 x 12 7 12f 2 Screws M4 x 13 12g 4 Screws M6 x 80 12h 4 Screws 6 x 70 12q 4 Screws 3 5 x 9 5 21 1 Drilling template 22 8 Wash...

Page 10: ...lings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and...

Page 11: ...frame by turning it Make sure that the screws do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is subjected to bending In all cases where the ceiling is not strong enough at the sus pensio...

Page 12: ...12e 2 9 x 12 7 provided Similarly position the lower chimney section and fix the low er part to the frame using the 2 screws 12e 2 9 x 12 7 provid ed Before fixing the hood canopy to the frame Screw the 2 screws 12f half way into the holes provided in the sides of the bottom of the frame Remove the grease filters from the hood canopy Remove any activated charcoal filters Lift the hood canopy and e...

Page 13: ... the filters alarm is triggered the alarm can be reset by pressing and holding this button for approximately5 seconds Led A flashes three times These indications are only visible when the motor is turned off When the procedure terminates the indication shown previously turns off F Flashing Indicates the need to change the activated charcoal filters and also to wash the metal grease filters The ala...

Page 14: ... refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activ...

Page 15: ...EN 2 27 ...

Page 16: ...EN 2 28 ...

Reviews: