background image

SS-1100 Low Profile 

Multi Use Air Mover

Rev A – August 9, 2019

OWNER’S MANUAL AND INSTRUCTIONS

C O M M E R C I A L   P R O D U C T S

Specifications

Operation

• 

Place air mover on a level and stable surface.  The SS-1100 can be placed flat on the surface with or without use 

of  the attached motor stand or placed horizontally on the surface.

• 

Plug unit into a Ground-Fault Circuit Interrupter (GFCI) electrical outlet rated for at least 115/120 VAC, 60 HZ 15 

amps.  This product must be grounded to reduce the risk of electrical shock.  Consult with a qualified electrician 

if you are in doubt whether an outlet is grounded and protected by a GFCI.

• 

Use the ON/OFF switch to operate the unit.

• 

Use carpet clamp proved for securing edge of carpet during drying.

Auxiliary Outlet

The unit comes with a built-in GFCI auxiliary outlet, allowing a daisy chain of up to six additional SS-1100 air mowers. 

The total amperage of all devices plugged into the receptacle must not exceed 12 amps.

The GFCI protects the user from potential electrical shocks.  Should it detect a sudden ground-fault, the GFCI will 

interrupt the current and shut off the unit.  It will trip when a short circuit or overload occurs.  If the GFCI trips, 

unplug the unit, and look for potential hazards such as standing water, a damaged cord or having too many devic

-

es plugged into the auxiliary outlet.  Once the problem is corrected, plug the unit back in, push the ‘Reset” button 

located on the GFCI faceplate, and re-start the unit.  If the unit does not re-start, please refer to the trouble shooting 

section of this manual. This product MUST BE GROUNDED.

Hour-Meter

This unit comes with a hour-meter that records the total time unit is running.

Power Cord Warning

Never operate a unit with a damaged power cord as this may lead to electrical or fire hazards. Never unplug the 

unit by pulling the power cord.  Grasp the plug firmly and  pull straight out  Precaution must be used to not damage 

the cord in any way.  Keep cords away from all water and heated surfaces.  Inspect cord before every use.  Replace 

any cord that shows any damage.

Operating Positions

Motor Stand Position

Flat Position

Horizontal Position

Summary of Contents for SS-1100

Page 1: ...he user from potential electrical shocks Should it detect a sudden ground fault the GFCI will interrupt the current and shut off the unit It will trip when a short circuit or overload occurs If the GFCI trips unplug the unit and look for potential hazards such as standing water a damaged cord or having too many devic es plugged into the auxiliary outlet Once the problem is corrected plug the unit ...

Page 2: ... than 5 units high Unit is intended for indoor use only Do not use outdoors Electrical appliances can ignite flammable vapors or dust Do not use near combustible liquids gases or dusts Do not leave plugged into outlet when not in use or when servicing Turn off unit before unplugging To reduce the risk of inhaling toxic vapors do not use near toxic or hazardous materials Do not operate with safety ...

Page 3: ...ged due to improper gas or electric service damaged in transit or that have been repaired or modified by others without Manufacturer s written authorization Buyer shall have no right to enforce this Warranty unless it has complied with all of its obligations under the contract for purchase lease of the Products including without limitation being current on all payment terms THIS LIMITED WARRANTY I...

Page 4: ...causing Exces sive Vibration Excess buildup of dirt on fan Motor shaft bent Fan blades bent Clean blades and grills Contact service or replace unit Contact service or replace unit Product making unusu al noises Damaged housing Damaged fan blades Damaged motor shaft Contact service or replace unit Contact service or replace unit Contact service or replace unit Blower wheel does not rotate motor mak...