background image

9

A

B

A.

Cable compartment lid

B.

"ON" LED light

1.OVERVIEW

2.Connections/buttons/led lights

USB CONNECTION

CONNECTION AT SIN.EQRTU1T

Before connecting anything, switch the power o

, complete the cabling, close the lid and

power the device on.

TROUBLESHOOTING

1) The device does not start:

2) The blue LED light does not stop 

ashing:

3) Not all the meters are revealed:

3.WALL FASTENING AND CABLE PASS

Temperature range:

Ingress Protection:
Protection Class:
Fastening:
Dimensions:
Power supply:

Consumption:
Radio Frequency:
W. M-Bus Mode:
Max distance between
two RPT868XT:

7.TECHNICAL DATA

1

2

3

+55°C

SIN.EQRPT868XT - QuickStart Guide

-20°C

DOCUMENTATION DOWNLOAD

: http://www.sinapsitech.it/en/area-download/

SIN.EQRPT868XT_QSG_2.5_en

Wireless M-Bus GATEWAY

Sinapsi Srl

 reserves the right to make changes to this product without any notice 

  - in case of network power supply, check that the power is on

  - in case you are using a USB port, check the USB cable quality and that the PC is enabled to handle 

    500 mA of electrical power

  - check that the meters that were not revealed are not too distant from SIN.EQRPT868XT or that 

     the signal is not disturbed by thick concrete or metal walls

  - check that the devices are on the list loaded in SIN.EQRPT868XT or that the W. M-Bus devices 

     list receivable from SIN.EQRPT868XT is not blocked

  - warning: some W. M-Bus devices transmit periodically (within hours)

  - check that the MESH network is not interrupted using SIN.EQRTU1T web interface or SIN.EQSW1 sw

- W.M-Bus 868 MHz / OMS EN13757 data gateway

- Remarkable radio coverage due to multi-hop network

  architecture (MESH)

- Manages up to 500 meters

- Last acquired data stored in a non-volatile memory

- Easy installation with software setup

- Simple and elegant design

- 100..240Vac power or via USB

- "Wall mounting" like installation

- USB interface for local data reading

- Optional WEB interface usable with SIN.EQRTU1T

1

2

1 - Power input 100..240Vac (with clips)

2 - Multifunction button

3 - Multifunction button

4 - Reset button

5 - USB port

3 4

6 - MESH network TX-RX LED

7 - W. M-Bus network TX-RX LED 

8 - Signal/reception level LED

9 - State LED 

5

6 7

8

SIN.EQRPT868XT gateway devices are provided with a MESH- ID=1 and channel 13. 

Make sure that all the gateways and/or SIN.EQRTU1T have the same MESH network ID and radio 

channel through SIN.EQSW1

Operative: -20°C ... +55°C
Storage: -25°C ... +85°C
IP 40 (EN60529)
II
wall clipped
LxHxP 160x160x35mm
100..240Vac 50/60Hz
USB (5Vdc, 500mA) for commissioning
4.5W
868MHz - Max transmission power: 27dBm
S / T / C +T / S & C+T

500mt free 

eld - 40mt in building

   - check that the device SIN.EQRTU1T  is on and that the antenna is connected and in good position 

     (avoid placing it in switchboards or shielded environments)

   - 1 blink "RAM memory error", 2 blinks "W.M-Bus radio module error", 

     3 blinks "MESH radio module error", 4 blinks "FLASH memory error", 5 blinks "Real Time Clock error" 

   - If turning o

 and restarting the SIN.EQRPT868XT,  the error does not reset, the hardware must be replaced.

   - check that SIN.EQRPT868XT is at least 5 metres distant from SIN.EQRTU1T  and from other SIN.EQRPT868XT

   - check that the ID and the MESH network channel are correct using SIN.EQSW1 sw and are the same ones  

     used by SIN.EQRTU1T    

1 - upper hole

2 - low pre-hole

3 - cable pass pre-hole

4 - power supply connection

6. GATEWAY NETWORK CONFIGURATION

1. Power on SIN.EQRTU1T, connect to web interface and start antenna and device scan following the user’s manual

2. Power on the 

rst device SIN.EQRPT868XT to be installed and move it away to a minimum distance of 5 metres 

    from SIN.EQRTU1T

3. Fixed blue SIN.EQRPT868XT LED shows the connection to the MESH network

4. Once connected, it shows the MESH radio signal quality to the gateway, by turning on the green 

    front LED, 1 – insu

cient reception, 2 – su

cient, 3- good, 4 – excellent

5. Put SIN.EQRPT868XT in a place where the reception signal is >=2 and the reception of all the W. M-Bus 

    devices you expect to receive with this antenna is satisfactory

6. Check  through SIN.EQRTU1T web interface or through SIN.EQSW1 software and a PC connected to the antenna 

    by USB that W. M-Bus devices, that you want to receive, reach the SIN.EQRPT868XT 

7. Fasten the SIN.EQRPT868XT and proceed with powering a second gateway keeping it at least 5 metres away from 

    both the SIN.EQRPT868XT and SIN.EQRTU1T  

8. Once connected, it shows the MESH radio signal quality to the gateway, by turning on the front LED, 

    so proceed as for the 

rst SIN.EQRPT868XT.

a) The scanning phase is 12 hours. You can modify its duration through SIN.EQRTU1T

b) You can have various independent SIN.EQRPT868XT networks in the same building. In that case, 

    you need to have di

erent  ID or channel for each SIN.EQRPT868XT group and the relative SIN.EQRTU1T. 

    You can modify these parameters through SIN.EQSW1 software installed on a pc and connected via USB to 

    SIN.EQRPT868XT, see user’s manual for details.

c) In case the receiver receives more than 500 W. M-Bus devices or it receives devices belonging 

    to other plants, it might be necessary to make it selective. Therefore, you can load a list of W. M-Bus devices 

    marked by their serial number through SIN.EQSW1 software. 

    In this way, the gateway will receive the data exclusively from the listed devices.

d) The USB / Mini USB cable is not included and is not present in the package. 

2 x Anchor 5x25

2 x Screws 5x30

2 x Glands

1 x SIN.EQRPT868XT

4.PACKAGE CONTENT

N

Power

supply

connection

2 x Screw  2,2x9,5

1 x clamp headband

SIN.EQRTU1T

MIN 5 m

MIN 5 m

MIN 5 m

USB

Mini USB

5.POSITIONING AND OPERATING DISTANCES

MAX 25 m

MAX 25 m

SIN.EQRTU1T

SIN.EQRPT868XT

FLOOR 1

FLOOR 0

MAX 15 m

SIN.EQRPT868XT

FASTENING

WALL

WALL

CEILING

MIN

20 cm

MIN

20 cm

1) Fix the SIN.EQRPT868XT gateway on fastening wall at a minimum 

    distance of 20 cm from the ceiling and from the adjacent wall.

2) The maximum operating distance between the devices 

    installed on the same 

oor is 25 meters, with no major 

    obstacles such as reinforced concrete or metal walls, columns 

    or beams or other metal structures.

3) The maximum operating distance between the devices 

     installed on di

erent 

oors is 15 meters.

MIN 5 m

SIN.EQRPT868XT

MIN 5 m

SIN.EQRPT868XT

MAX 25 m

MAX 15 m

Manufactured by SINAPSI SRL - Via delle Querce 11/13 - 06083 Bastia Umbra (PG) - Italy

For details on the con

guration of the SIN.EQRPT868XT using the buttons, see the back of this

document, in the dedicated section.

L

max 2x1,5 mm