background image

 

Sigmann DELTA GmbH 

Tel. 06268-92899-73 

Commercial Register 

Volksbank Kraichgau 

Hauptstraße 53 

Fax 06268-92899-74 

Mannheim HRB 703603  

BLZ 672 922 00 Konto 55258007 

D-74928 Hüffenhardt 

[email protected] 

Manager 

S.W.I.F.T.-Code GENO DE 61SSH 

UstIDNr: DE257944309 

http://www.sigmann-delta.de 

Joachim Kraus 

IBAN DE31 6729 2200 0055 2580 07 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date: 10.10.2013 

 

 

Operating Instructions 

Bluetooth Handheld Scanner SD160BT

ex

 

Type SD.113.000.0x 

Summary of Contents for SD160BTex

Page 1: ...annheim HRB 703603 BLZ 672 922 00 Konto 55258007 D 74928 Hüffenhardt info sigmann delta de Manager S W I F T Code GENO DE 61SSH UstIDNr DE257944309 http www sigmann delta de Joachim Kraus IBAN DE31 6729 2200 0055 2580 07 Date 10 10 2013 Operating Instructions Bluetooth Handheld Scanner SD160BTex Type SD 113 000 0x ...

Page 2: ...Operating Instructions_SD160BTex_002 ...

Page 3: ...ed base charging station 9 3 2 System assembly 2 Non explosion protected base charging station 10 3 3 Cable range in system assembly 1 11 3 4 Cable range in system assembly 2 11 4 Step by step guide on installation and operation 11 4 1 Step 1 Preparation handheld scanner SD160BTex 11 4 2 Step 2 Using base charging station for system 1 12 4 3 Step 2 Using base charging station for system 2 13 4 4 S...

Page 4: ...on Warnings are highlighted by a special symbol and a different font colour Danger Non compliance may result in life threatening situations This warning must be heeded Warning This type of warning concerns dangerous situations that may result in minor injuries Info Important and helpful notes and information ...

Page 5: ...ensure that they have the most up to date version of the operating in structions To make sure this is the case please check Sigmann DELTA s website at www Sigmann DELTA de or contact one of the company s staff The drawings contained in these operating instructions are for illustration purposes only and may differ somewhat from the actual design No changes may be made to the device that were not in...

Page 6: ...s are used explosion protec tion is no longer guaranteed Ensure safe handling with firm footing and sufficient room for movement If the enclosure is in any way damaged the device must be removed from the hazardous area immediately In accordance with IEC 60079 19 and IEC 60079 17 operators of electrical installation in hazardous areas are obliged to have them serviced by qualified electricians Do n...

Page 7: ... looking directly into the light Brief expo sure to a class 2 laser is deemed not dangerous Maintenance Provided the device is operated and assembled according to instructions and the ambient requirements are being met continuous maintenance is not neces sary Servicing Operators of electric equipment in hazardous areas are obliged to have them serviced by qualified electricians IEC 60079 19 and IE...

Page 8: ...0x 2 2 Explosion protection II 2G Ex ib IIC T4 II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135 C II 2D Ex ib IIIC T135 C Db Protection category IP65 2 3 Technical Data Handheld scanner Nominal values Light source Visible red light 630nm Ambient temperature 20 C to 50 C Test certificate IBExU 12 ATEX 1162 Bluetooth V2 1 EDR Weight 260g inc batteries Bluetooth range up to 30 m ...

Page 9: ...ation may be operated in hazardous areas Its purpose is to re ceive data captured by the associated handheld scanner 1D bar codes or 2D stacked codes via Bluetooth Nominal values of the hazard ous base charging station maximum input voltage Ui 4 9 V SD Z10 0010 xx SD Z10 0011 xx 5 6 V SD Z 10 0007 xx maximum input current li 490 mA maximum input power Pi 1 25 W maximum internal inductance Li negli...

Page 10: ...12 0x and a power supply SDVM125ex depending on voltage and interface SD 211 XX11 00 SD 114 0000 00 Explosion protected base charging station SD Z10 0015 00 Non explosion protected base charging station SD Z10 0014 00 Non explosion protected charging station without Bluetooth 2 6 Serial numbers Serial key year of manufactur serial number 2 numbers 4 numbers Example 130001 2 7 Application The scann...

Page 11: ...ex power supply SD 211 xx11 00 and a connection cable between the power supply and a PC Required connection cable to a PC USB 0 2 2 5 mm 4 wire or RS232 0 2 2 5 mm 3 wire The Bluetooth handheld scanner the base charging station and the power supply can be connected and operated in the hazardous area For safe installation of the power supply please refer to the manual issued by SICK AG www SICK com...

Page 12: ...d SD160BTex scanner SD 113 0000 0x can also be used separately in the hazardous area The base charging station SD Z10 0015 00 is then operated in the non hazardous area Use an RS232 cable SD Z10 0012 0x or a USB cable SD Z10 0013 0x to connect the station directly to a pow er supply and a PC The warnings and notes of caution contained in these operating instructions and in the manu al issued by SI...

Page 13: ...e charging station 1 8 or 3 8m optional with 4 5m or 6m extension SDVM125ex Up to 20m Host USB SD160BTex Base charging station 1 8 or 3 8 m SDVM125ex Up to 5m Host RS232 SD160BTex Non hazardous base charging station 1 8 or 3 8m optional with 4 5m or 6m extension Host USB SD160BTex Non hazardous base charging station 1 8 or 3 8 m Host ...

Page 14: ...ment After the screw has been loosened the removal of the lid requires a certain amount of force An SD Z10 0018 00 accu is required to operate the Bluetooth handheld scanner SD160BTex Only use this accu for the Bluetooth Scanner Before placing the accu inside the scanner remove its protective cap Insert the accu into the accu compartment of the scanner The end of the removal strap must be protrude...

Page 15: ...sert the cable in the opening at the bottom of the base charging sta tion If the cable has been inserted fully you can hear a click Check if the cable fits firmly Insert the plug of the connection cable into the power supply s plug connector Ensure that the connection is fully secured with the screw cap after the plug has been inserted Place the SD160BTes handheld scanner onto the charging station...

Page 16: ...the base charging station in a non hazardous area the connection cable for the power supply and the PC is inserted in the opening at the bottom of the base charging station Use SD 10 0012 as a RS232 cable and SDZ10 0013 00 as a USB cable If the cable has been inserted fully you can hear a click Check that the cable fits firmly Place the SD160BTes handheld scanner onto the charging station Insert t...

Page 17: ...ating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened Any changes to the terminal assignment may only be carried out by trained staff Connection of base charging station to the RS232 power supply with plug connection Base connection cable RS232 Typ SD Z10 0010 0X Power Supply Typ SD 211 X011 00 Pin assignment connection ...

Page 18: ...onnection with cable end sleevs To fully operate the handheld SD160BTex scanner you will require the programming information contained in the manual published by SICK AG www SICK com Base charging station SD160BTex RS232 RJ 45 Pin assign ment Wire colours Definition Assignment 6 White TXD X9 X10 X11 7 Brown GND X12 3 Yellow UB X13 intrinsically safe connection box of the SDVM125ex RS232 power supp...

Page 19: ...operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened Any changes to the terminal assignment may only be carried out by trained staff Connection base charging station to the USB power supply with plug connection Base connection cable USB Typ SD Z10 0011 0X Power Supply Typ SD 211 X111 00 Pin assignment connection cou...

Page 20: ... with cable end sleevs Base charging station SD160ex USB RJ 45 Pin assign ment Wire colours Definition Assignment 2 Green D 2SL X9 10 White D 2SL X10 X11 7 Black GND X12 3 Brown UB X13 intrinsically safe connection box of the SDVM125ex USB power supply after removal of the wires of the plug connection To fully operate the handheld SD160BTex scanner you will require the programming information cont...

Page 21: ...Operating Instructions_SD160BTex_002 19 5 1 EC type examination certificate SD160BTex and SD160BTex base charging station 5 Attachment ...

Page 22: ...Operating Instructions_SD160BTex_002 20 ...

Page 23: ...Operating Instructions_SD160BTex_002 21 5 2 EC type examination certificate Power supply SDVM125ex ...

Page 24: ...Operating Instructions_SD160BTex_002 22 ...

Page 25: ...Operating Instructions_SD160BTex_002 23 ...

Page 26: ...Operating Instructions_SD160BTex_002 24 ...

Page 27: ...Operating Instructions_SD160BTex_002 25 Sigmann DELTA GmbH Hauptstraße 53 D 74928 Hüffenhardt Tel 49 0 6268 92899 73 Fax 49 0 6268 92899 74 info sigmann delta de 6 Contact ...

Reviews: