background image

8AA9978 - D0 -05/10/

2003

 - UK -

Fig. 1

Fig. 2b

Fig. 3

Fig. 2a

1. Product description

The WAC 11 is used to verify audio alarms.  It is fitted with a 
speaker and microphone. The audio signal is connected directly 
to the central control unit via an audio module (e.g. WMA 11) or 
via a WAC 12, which acts as a master.

2. Supply package

The WAC 11 UK package contains the following
-     One WAC 11
-     One WLC 11 UK language kit complete with:
      -  Installation instructions.

3. Mounting instructions

The WAC 11 is designed for mounting in dry indoor rooms. 
To ensure good acoustics, note the following points.
-  Mount 2 to 2.5 m above floor level.
- Maintain adequate distance from noise sources (ven ti la tion    
   openings, fans etc.).
- Direct towards the centre of the space to be monitored.
-  Do not mount on vibrating surfaces.
- The maximum length of the audio connection between the    
   WAC 11 and central control unit is 200 m.

3.1 Opening the  housing (Fig.1)

1 -  Using screwdriver 

Q

, press locking tab to release.

2 -  Lift off cover 

W

.

3.2 Product overview (Fig. 2)

-  Knockouts 

Q

T

 for cable inlet.

-  Knockouts 

W

E

 for attachment of housing.

-  Knockout 

R

 for disconnection monitor screw.

-  Speaker 

Y

.

-  WMC 11 circuit board 

U

.

3.3 WMC 11 circuit board (Fig. 3)

- Audio connection 

O

.

-  Tamper output 

I

-  Free terminal 

U

- LED 

W

, flashes to outside during monitoring (microphone 

   active).
-  Switch 

E

 for "microphone active" LED.

-  Tamper switch 

Y

.

-  Microphone  

R

.

-  Potentiometer 

Q

 for speaker volume.

-  Potentiometer 

T

 for microphone sensitivity.

s

Installation Instructions

WAC 11

WLC 11 UK

20 800 056.0-010

W

Q

W

E

R

T

Q

Y

U

NC

T

-A

+A

T

Q

W

R

T

Y

U I

O

E

DS1

NC

T

-A

+A

T

Reviews: