Страница 1: ... Information and Communications optiPoint 300 basic IP Telephone Operation and Andministration Manual ...

Страница 2: ...chaft All other brand and product names may be trademarks of their respective holders Siemens AG provides this documentation without any warranty of any kind either implied or expressed including but not limited to the implied warranties of merchantability or fitness for a particular purpose ...

Страница 3: ...effect 10 Service 10 Notes and symbols 11 Safety 11 Symbols in the manual 11 Product description 12 Overview 12 Features 12 Layout of the telephone 13 Standard package 14 Display and controls 15 Display 15 Symbol keys 16 Programmable keys 17 Control keys 17 Installation 18 Preparing the telephone 18 Integrating the telephone into the communication environment 19 Loading the application software 19...

Страница 4: ...tween callers 29 End consultation 29 Terminating a connection 30 Ending a call 30 Your caller hangs up 30 Changing the settings 31 Turning on the speakerphone 31 Adjusting speakerphone volume 31 Using the mute control 32 Turning on the speakerphone 32 Enable call waiting 33 Display elapsed call duration 33 Display your telephone number 33 Adjusting handset volume 34 Adjusting ringer volume 35 Adju...

Страница 5: ...ey click 48 Administration 49 Firmware version read only 49 Application version read only 49 IP assignment by DHCP 50 GK discovery IP 50 HiPath 51 Telephone number 51 IP address 52 Subnet mask 52 Gatekeeper s IP address 53 Download server s IP address 53 SNTP server IP address 54 Time zone offset 54 Terminal NIC MAC read only 55 HiPath PIN 55 Administration from a web server 56 Diagnostics 57 Disp...

Страница 6: ...ameset 67 Home page 68 HiPath administrator login 68 Local administrator login 69 Administration 69 General information 70 Administrator settings 70 IP address and routing 71 Gatekeeper information 72 Speech parameters 72 Time date 73 File transfer 74 FTP username password 75 SNMP information 75 Download application 76 Save upload configuration 76 Restore download configuration 77 Restart terminal...

Страница 7: ...80 Error messages 80 Configurations 81 Country settings 81 Factory default settings 82 Local functions 82 Audio 82 Configuration 83 Administration 84 Diagnostics 84 Technical data 85 Abbreviations 86 Index 87 ...

Страница 8: ...special LAN ca ble Never open the power supply enclosure Protection of the telephone The telephone must not be used in bathrooms etc as it is not splashproof Before connecting or disconnecting the LAN cable or the headset cord pull the power plug out of the plug receptacle first Location of the telephone The telephone should be operated in a controlled environment with an ambient temperature betwe...

Страница 9: ...nuing through the setting of all oper ating parameters and ending with the special functions and ad ministrative tasks at the end of the manual The separate quick ref erence guide brings together basic information on the most commonly used functions Intended use The optiPoint 300 basic telephone is a desktop unit designed for voice transmission and for connection to a LAN It can be operated also a...

Страница 10: ...the loudspeakers and microphones need to be repositioned Service In the case of any trouble or defects on the unit itself please dial the service number of your country The Siemens service department can only help you with trouble or defects on the unit itself Should you have any questions regarding the opera tion your specialist retailer or network administrator will gladly help you with the righ...

Страница 11: ... manual The operating steps of actions are shown as follows Lift the handset Dial the required number Where several different options or possibilities are described they are shown like this Option A Option B This symbol indicates a hazard Failure to follow the in structions given may result in injury or in damage to the unit Key information important for the proper use of the unit is marked with t...

Страница 12: ...video conferences via a LAN The optiPoint 300 basic supports other standard protocols optimizing data and voice transmission and simplifying the associated network administration task It is for ex ample possible to download updates of equipment software or ex tended features to the optiPoint 300 basic via an FTP server The optiPoint 300 basic is provided with a one line display and special functio...

Страница 13: ...he telephone 1 handset 2 key block with 3 function keys 3 one line numerical display 4 key block fourteen quick dial keys and two special function keys 5 key block with 4 function keys 6 dialling keypad 7 function key 8 two control keys ...

Страница 14: ...ists of the following items IP phone optiPoint 300 basic Handset Handset cord LAN cable Power supply unit Installation and Startup manual not shown Quick Reference Guide not shown CD ROM with the Operation and Administration Manual not shown Set of overlays for programmable quick dial keys not shown ...

Страница 15: ...otal of twelve available In idle mode the optiPoint 300 basic displays the current date on the left side of the bottom line and the time of day on the right side Pictograph Explanation Programming mode active DTMF outband is active Handset mute is on Not used Initialising data is being input Not used Call waiting is enabled In consultation or alternate mode Elapsed call duration is being displayed...

Страница 16: ...e calling turn elapsed call duration display on or off While in programming mode set date and time Line editor mode short press deletes the last character long press deletes the whole line Mask editor mode position insert point cursor Dial the displayed number when handset is lifted While in programming mode or service mode confirm action j While calling switch loudspeaker on or off While in progr...

Страница 17: ...s and are located above thej key De pending on the operating mode you can vary the following set tings CW key Controls the call waiting function Service key Controls the service and programming modes Operating mode key key Idle mode Reduce the display contrast Increase the display contrast Receiving a call Reduce the volume of the ringer tone Increase the volume of the ringer tone Using the handse...

Страница 18: ...ailed informations in the chapter entitled The web pages Preparing the telephone To connect the telephone components proceed as follows Latch the Western plug of the handset cord in the handset receptacle short end Latch the other end of the cord in the receptacle 3 on the bottom of the telephone long end Feed the cord through the guide channel in the base unit Latch the LAN cord with the eight pi...

Страница 19: ...g the application software When the optiPoint 300 basic telephone is connected to power it automatically boots up i e loads and executes the application software During the boot phase you will see three dashes scroll ing across the display from left to right If the boot phase cannot be completed successfully because of missing or defective application software you will see In such a case please as...

Страница 20: ...tion For five seconds the display will show After that the telephone goes into idle mode You may break off initialisation at any time by pressing the h key Any settings previously entered will be cancelled and you will be returned to the point at which you were asked to enter the admini strator s PIN If an SNTP server is located within the HiPath environment the te lephone unit will automatically ...

Страница 21: ...to the point at which you were asked to enter the admini strator s PIN If an SNTP server is located within the HiPath environment the te lephone unit will automatically get the correct date and time from it Otherwise you must manually enter this information as descri bed in the chapter entitled Configuration and administration Flashing programming and initialisation symbols flashing dash line Ente...

Страница 22: ...r lays and label them in accordance with their intended function Push forward the transparent foil cover of the labelling cards and remove it Take out the key overlays and write the required names or functions on it Place the labelling cards in the recess and fix the transparent foil cover into place ...

Страница 23: ...the complete number just entered or to return to the start of the num ber You may also enter an IP address instead of a telephone number To do this separate the three digit groups of the address by press ing the asterisk separator In the display this will show up as the underline character _ Specialised functions are selected using the appropriate symbol keys The meanings of the symbol keys depend...

Страница 24: ... number Dialling with handset picked up The number you have entered will be checked If you have entered an IP address incorrectly the error tone will sound You can then correct the IP address Once the call has been placed the standard display for an active telephone connection will come on the screen 12 03 00 12 34 Idle mode Pick up handset 0089722_ Enter telephone number or 132_075_200_ enter IP ...

Страница 25: ... the call has been placed the standard display for an active telephone connection will come on the screen 12 03 00 12 34 Idle mode 0089722_ Enter telephone number or 093_324_5_ Enter IP address Pick up handset to start dialling When entering an IP address you must separate the three digit groups of the address with asterisks In the display this will show up as the underline character _ 00897221234...

Страница 26: ...ification CLIR your unit will display the rele vant symbol instead of the number If there is an incoming call and CW is off while the optiPoint 300 basic is in programming mode or service mode the caller will hear a busy signal The programming or service in progress will not be affected Incoming call while in idle mode Picking up an incoming call The optiPoint 300 basic rings and the caller identi...

Страница 27: ...are on the line speaking to your first caller the active connection is displayed If a second call comes in you will see The first caller will be kept on hold as long as you keep the con nection with the second one The second call is ended and the first call is resumed Turning down the second call offer 0093387654 Call waiting flashing new caller ID displayed R CWtone pick up new call 2 0093387654 ...

Страница 28: ...rd individual by placing a new call Place a second call If there is no response to your call you can terminate consultation by pressing h which will return you to your first caller 008972212345 Active connection R Request consultation 1 008972212345 Current call becomes connection no 1 2 Enter the new number you wish to call 2 0093387654 Start dialling ...

Страница 29: ... be returned to your first caller who has been on hold 1 008972212345 Connection no 1 is active R Change to the connection currently on hold 2 0093387654 Connection no 2 becomes the active connection R Return to connection no 1 if desired 1 008972212345 Connection no 1 is resumed as the active connection 2 0093387654 Connection no 2 is active h End consultation call no 2 is terminated 008972212345...

Страница 30: ...ear the ringer To end a call replace the handset Your caller hangs up If your caller hangs up before you have had a chance to pick up the handset the telephone will go into idle mode If your caller hangs up while you are on the line you will hear a busy signal The telephone will then return to idle mode If a second call is on background hold when the current con nection is ended you will be return...

Страница 31: ...its cradle the speakerphone will be turned off automatically Adjusting speakerphone volume With the speakerphone on you can adjust it to the desired volume as you speak 008972212345 Current connection or _____ Current volume setting or ___ Volume setting is adjusted immediately Confirm and save the new setting 008972212345 Current connection If no setting changes are made the optiPoint 300 basic r...

Страница 32: ...activated Turning on the speakerphone You can turn on the speakerphone on during a telephone call When you replace the handset in its cradle the speakerphone will be turned off automatically 008972212345 Current connection is blinking q Activate mute 008972212345 Mute symbol is displayed the mute LED lights 008972212345 j Deactivate mute 008972212345 Current connection j Turn on speakerphone the c...

Страница 33: ...different calls the call duration display will be replaced by a display of the active connection to al low you to identify the callers Display your telephone number In idle mode you can have the assigned telephone number of your optiPoint 300 basic shown on the display After displaying the telephone number the optiPoint 300 basic au tomatically reverts to idle mode CW Press special function key CW...

Страница 34: ... or _____ Current handset volume setting or ___ Volume setting is adjusted immediately Confirm the new setting 008972212345 Current connection If no setting changes are made the optiPoint 300 basic re turns to the standard display after three seconds Any changes you made but did not confirm will remain effec tive but only for the duration of the current call ...

Страница 35: ...tification or _____ Current ringer volume setting or ___ Volume setting is adjusted immediately Confirm the new setting 008972212345 Caller identification If no setting changes are made the optiPoint 300 basic re turns to the standard display after three seconds Any changes you made but did not confirm will remain effec tive but only for the duration of the current call ...

Страница 36: ...2 03 00 12 34 Idle mode or __ Current contrast setting or Contrast setting is adjusted immediately Confirm the new setting 12 03 00 12 35 Idle mode If no setting changes are made the optiPoint 300 basic returns to the standard display after three seconds Any changes you made but did not confirm will have no effect ...

Страница 37: ...se redial to call again the number that was last called from the telephone Press the redial key to dial the last number again Quick dial feature You can assign frequently called numbers to the quick dial keys allowing you to call them by pressing just one key You can also press several keys in a row for example if you want to enter a number for a call by call provider Press a quick dial key to get...

Страница 38: ...u have made will be cancelled Press to confirm your programming changes this will be acknowledged with an au dible signal Programming the quick dial keys The optiPoint 300 basic has fourteen quick dial keys For each of those keys you can assign a telephone number or an IP address You will be able to call them by simply pressing the key 12 03 00 12 34 Idle mode Service Press special function key Se...

Страница 39: ... setting see page 81 Note that all four digits must be given for the year 12 03 00 12 34 Idle mode Service Press special function key Service to change to service mode Do not enter PIN Select redial Programming mode 00897221234_ Edit or erase redial number Save changes 12 03 00 12 35 Idle mode 12 03 00 12 34 Idle mode Service Press special function key Service to change to service mode Do not ente...

Страница 40: ...ess t for tune and 5 for sequence The current set ting is displayed its value corresponding to the length of the dashed line shown and the ringer will sound so that you can hear what the setting corresponds to Press j to accept the setting of the current parameter and move on to the next To confirm your changes and exit press Changing ringer loudness 12 03 00 12 34 Idle mode Service Press special ...

Страница 41: ...new settings t _____ current tune setting or t ___ Tune changes ringer will sound j Save changes and move to sequence parameter 5 _ Current sequence setting or 5 _ Sequence changes ringer will sound Save changes audible acknowledgement signal 12 03 00 12 34 Idle mode ...

Страница 42: ... call waiting has been disabled then the caller will receive a busy signal while you are working on your phone in programming mode Ignoring the call offer Picking up the new call Alternately use the h key to pick up the call without saving the changes you have made to the settings _____ Caller announced while in programming mode CW Turn down the offer of the new call _____ Programming mode _____ C...

Страница 43: ... car ried out by a designated network administrator The optiPoint 300 basic can be treated like any other piece of net work user equipment connected to the LAN Adjustment of settings and performance of administration tasks are always done in the service mode The initialisation symbol indicates that you are in service mode Access to this mode is protected by means of an administrator PIN A web serv...

Страница 44: ...ve them unchanged or modify them using the dialling key pad When you are finished save the changes and exit If you make an invalid entry you will hear the beep signalling an error When this happens simply enter the correct value 12 03 00 12 34 Idle mode Service Press special function key Service to change to service mode Enter PIN Conform PIN 5F Service mode 5F 101 Select function Confirm function...

Страница 45: ... basic will return to idle a beep will signal that you have ended service mode To stop your work in service mode at any time simply pressh The current not confirmed saved setting will be lost All other ed ited points who were confirmed before will remain changed Exit service mode 12 03 00 12 35 Idle mode ...

Страница 46: ...all waiting has been disabled then the caller will receive a busy signal while you are working on your phone in service mode Turning down the call offer Picking up the new call Alternately use the h key to pick up the call without saving your changes 5F Caller announced while in service mode CW Turn down the offer of the new call 5F Service mode symbol stops flashing 5F Caller announced while in s...

Страница 47: ...y format and dialling parameters The table on page 81 gives a list of the possible country codes DTMF dialling Choose the correct dialling method here There are two dialling methods available 1 Inband 2 Outband If you have selected 2 the symbol will be displayed 5F _ Service mode 5F 101 Select country setting Confirm 5F 101 01 Change country setting Save change 5F _ Service mode 5F 102 Select dial...

Страница 48: ...p to click every time you press a key You can adjust the volume of this tone which is independent of the loudspeaker volume The click will not be heard by your call ers There are four possibilities for this setting 0 no key click 1 quiet click 2 moderate volume click 3 loud click 5F _ Service mode 5F 103 Select DST setting Confirm 5F 103 1 Enable or disable setting Save change 5F _ Service mode 5F...

Страница 49: ...nly You can read the current firmware version It will be displayed but cannot be modified Application version read only You can have the current version of the application displayed but it cannot be modified 5F _ Service mode 5F 201 Select firmware version Confirm 5F 201 026 Current firmware version 5F _ Service mode 5F 202 Select application version Confirm 5F 202 100 Current application version ...

Страница 50: ...r 2 local IP address is to be used GK discovery IP You can specify the gatekeeper discovery IP address here 5F _ Service mode 5F 203 Select DHCP IP assignment Confirm 5F 203 1 Change setting Save change When you change this setting the system will automat ically re boot The former IP address will be erased 5F _ Service mode 5F 204 Select GK discovery IP Confirm P3 233 123 156 189 Change IP address...

Страница 51: ... environment 2 HiPath Off Telephone number You can display the telephone number E 164 address of your unit and change it if desired The default setting is zero 5F _ Service mode 5F 205 Select HiPath setting Confirm 5F 205 2 Change setting as required Save change 5F _ Service mode 5F 206 Select telephone number setting Confirm P2 022 12345 Change number as required Save change ...

Страница 52: ...gned IP address but you will be able to change it Subnet mask Specify the subnet mask address The current address is given as the default value 5F _ Service mode 5F 207 Select IP address Confirm 1P 132 075 100 169 Change IP address Save change When you change this setting the system will automat ically re boot after leaving service mode 5F _ Service mode 5F 208 Select subnet mask Confirm P1 255 25...

Страница 53: ...ownload server s IP address You must specify the IP address of the server that will be used to download the application 5F _ Service mode 5F 209 Select gatekeeper IP address setting Confirm P4 244 233 250 123 Change setting Save change 5F _ Service mode 5F 210 Select download server Confirm P5 199166 224 123 Change IP address Save change ...

Страница 54: ...t ahead or back the required number of hours You can enter any offset setting between 12 and 12 hours A neg ative value means that your local time is earlier than universal time a positive value means that it is later 5F _ Service mode 5F 211 Select SNTP setting Confirm P6 244 189 012 245 Change server s IP address Save change 5F _ Service mode 5F 212 Select time zone offset Confirm 5F 212 07 Chan...

Страница 55: ...hange it HiPath PIN If you use the telephone in a HiPath environment the HiPath op tion is set to 1 see function no 205 you must enter a HiPath PIN 5F _ Service mode 5F 213 Select NIC MAC Confirm P7 08 00 2A 3b 4C 5d Setting is displayed 5F _ Service mode 5F 214 Select HiPath PIN Confirm H1NEt d_ Enter your HiPath PIN ...

Страница 56: ...in period you will see three dashes scrolling across the display from left to right You can only transmit the changed data from the web server if the telephone is in idle mode Otherwise you will get a corresponding error message from the web server If the web server initializes diagnostics you can see the corre sponding displays on the telephone The optiPoint 300 basic is locked for incoming calls...

Страница 57: ...how on the display Keyboard test This test allows you to check the keys of your optiPoint 300 basic unit one by one as you press a key a click will sound to indicate that it has registered but without performing the normal function of the key 5F _ Service mode 5F 301 Select display test Confirm 8888888888888888888888 Display test End display test 5F _ Service mode 5F 302 Select keyboard test Confi...

Страница 58: ...ne RAM test This test allows you to check that the unit s RAM is free of defects 5F _ Service mode 5F 303 Select audio loop test Confirm Blow into microphone End audio loop test 5F _ Service mode 5F 304 Select RAM test Confirm 5F 304 Dash characters displayed while test in progress 5F 304 PA55Ed Test passed or 5F 304 FA1LEd Error signal sounds test failed RAM may be faulty End RAM test ...

Страница 59: ... you to check that the unit s ROM is free of defects 5F _ Service mode 5F 305 Select ROM test Confirm 5F 305 Dash characters displayed while test in progress 5F 305 PA55Ed Test passed or 5F 305 FA1LEd Error signal sounds test failed ROM may be faulty End ROM test ...

Страница 60: ...umber of all SNMP MIB2 errors 5F _ Service mode 5F 306 Select PING test Confirm 1P 213 156 189 012 Enter IP address Confirm 5F 306 Dash characters displayed while test in progress 5F 305 1203 Test passed elapsed time shown in milliseconds or 5F 305 FA1LEd Error signal sounds PING test failed End PING test 5F _ Service mode 5F 307 Select MIB2 Confirm 5F 307 0000000000 Number of MIB2 errors displaye...

Страница 61: ...actory default settings You can restore your optiPoint 300 basic unit s factory default set tings at any time Settings that have been changed with an admin istrator PIN can be reset in this way without having to enter the PIN To restore the defaults proceed as follows Put telephone into idle mode Disconnect from network Pick up handset Press keys 2 8 and 4 simultaneously You will see the following...

Страница 62: ...led for the duration of the procedure If you press a key an error signal will sound and the same will happen if you pick up the handset you will not hear the usual dial tone The optiPoint 300 basic telephone automatically reverts to idle mode once the web server procedure has been completed Web server administration procedure in progress dL Web server software download in progress 5F Web server di...

Страница 63: ... will move across the screen Once the down load has been completed after restart the unit will revert to idle mode If the download cannot be successfully completed an error mes sage will be sent to the web server In this case the existing tele phone software will not be overwritten A download from the web server can only be performed by the administrator not by a normal telephone user While the do...

Страница 64: ...uthentication server to check the creden tial If the credential does not give the necessary authorisation for the requested resource the client will be redirected to the login page The reason for the credential mechanism is that it potentially saves the client having to re logon at each managed entity visited If the location of the central authentication server is not known or access to it fails t...

Страница 65: ... beneath this menu will contain a link back to the menu page Ad hoc links between pages in different branches of the hi erarchy will also be used when appropriate When a client visits an optiPoint 300 basic page via a HiPath page the optiPoint 300 basic page will appear within the HiPath frameset If a link from a HiPath page is to any optiPoint 300 basic page other than the frameset then the optiP...

Страница 66: ...The web pages 66 Overall structure ...

Страница 67: ...eset Two horizontally oriented frames will be displayed within the browser window A banner frame This frame contains the site title standard links terminal iden tity and overall status It is solely for the banner page and will be a fixed height A content frame This frame is for all content other than the banner page It will occupy all the space that remains beneath the banner frame banner content ...

Страница 68: ...tor leads to Administration page via Administrator login if necessary HiPath administrator login The button Login leads to the requested page if the entered password is OK otherwise this page will appear again The button Cancel leads back to the Home Page ...

Страница 69: ...b pages 69 Local administrator login The button Login leads to the requested page if the entered password is OK otherwise this page will appear again The button Cancel returns to the Home Page Administration ...

Страница 70: ...The web pages 70 General information Administrator settings ...

Страница 71: ...The web pages 71 IP address and routing ...

Страница 72: ...The web pages 72 Gatekeeper information Speech parameters Options for Jitter buffer are Short Normal Long ...

Страница 73: ...The web pages 73 Time date ...

Страница 74: ...The web pages 74 File transfer Options for Action on submit are No transfer Upload configuration Download configuration Download application ...

Страница 75: ...The web pages 75 FTP username password SNMP information When this page is being shown the information fields will allways be empty for security reasons ...

Страница 76: ...The web pages 76 Download application Save upload configuration ...

Страница 77: ...The web pages 77 Restore download configuration Restart terminal ...

Страница 78: ...The web pages 78 Diagnostics ...

Страница 79: ...The web pages 79 Change administrator password ...

Страница 80: ...ry or press a key that is not available you will hear the audible error signal and the optiPoint 300 basic tele phone will ignore the invalid command or entry You can continue by pressing one of the available keys or making a valid entry Error message on display Error messages are displayed along the bottom part of the display The optiPoint 300 basic has two error messages Gatekeeper not found alt...

Страница 81: ...0 05 ES Spain DD MM YY 24 h 80 80 06 A Austria DD MM YY 24 h 80 80 07 CH Switzerland DD MM YY 24 h 80 80 08 B Belgium DD MM YY 24 h 80 80 09 GB England DD MM YY 24 h 80 80 10 NL Netherlands DD MM YY 24 h 80 80 11 S Sweden YY MM DD 24 h 80 80 12 P Portugal DD MM YY 24 h 80 80 13 L Luxembourg DD MM YY 24 h 80 80 14 DK Denmark DD MM YY 24 h 80 80 15 SF Finland DD MM YY 24 h 80 80 16 NO Norway DD MM Y...

Страница 82: ...l functions Audio Function Default setting Quick dial keys None Redial number None PIN for factory defaults 124816 Function Default setting Loudspeaker volume 4 Ringer volume 4 Ringer tone Melody 2 Sequence 2 Handset volume 2 Key click off ...

Страница 83: ...Annex 83 Configuration Function Default setting Country setting 01 Date Time Format MM DD YY Date 00 00 00 Time 00 00A Call waiting enabled DTMF mode Inband Display contrast 3 Daylight saving off ...

Страница 84: ...et 0 IP routing 0 0 0 0 all Firmware DL filename The file name ends with a character from a to d indicating the language package optiPoint 300 basica Config DL filename optiPoint 300 basiccf Administrator password 6 numeric values 123456 SNMP password 0 alphanumeric value min 24 max 123456 FTP password 0 alphanumeric value min 24 max 123abc HiPath password 1 numeric value min 9 max null FTP userna...

Страница 85: ...x RJ 45 TP Pin assignment LAN receptacle X401 Pin 1 TX Pin 2 TX Pin 3 RX Pin 4 Pin 5 Pin 6 RX Pin 7 Pin 8 Handset receptacle X501 Pin 1 microphone Pin 2 receiver cap Pin 3 receiver cap Pin 4 microphone Power supply unit receptacle X601 Pin 1 V Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 V Power supply external plug in power supply unit EU variant grounding plug 230 V 50 Hz UK variant 230 V 50 Hz US variant 110 ...

Страница 86: ...twork LAN Local Area Network LED Light Emitting Diode MAC Media Access Control MIB2 Managemant Information Base release 2 NIC Network Interface Card PIN Personal Identification Number PSTN Public Switched Telephone Network RAM Random Access Memory ROM Read Only Memory SNMP Simple Network Management Protocol SNTP Simple Network Time Protocol TCP IP Transmission Control Protocol Internet Protocol TF...

Страница 87: ...me 48 DHCP server 20 21 Display 15 display contrast 36 Download 63 Download server s IP address 53 E Echo effect 10 Error messages 80 Ethernet interface 12 F Factory defaults 61 82 features of the phone 12 Firmware version 49 G Gatekeeper s IP address 53 GK discovery IP 50 H handset volume 34 HiPath 51 HiPath 5500 5300 19 I idle mode 15 Inband 47 IP address 19 52 IP assignment 50 K Key click 48 L ...

Страница 88: ...27 serial number 9 service mode 44 SNTP server IP address 54 speakerphone 31 speakerphone volume 31 speakerphone turning on 32 Subnet mask 52 symbol keys 16 symbols 15 T TCP IP protocol 12 telephone number display 33 Telephone restart 61 Terminal NIC MAC 55 Time zone offset 54 U user help 10 user programmable keys 17 V volume of speakerphone 31 W web management interface 64 western plug 18 ...

Страница 89: ......

Страница 90: ...8 A101 2 7619 Gedruckt in der Bundesrepublik Deutschland Siemens AG 2000 Information and Communication Networks Hofmannstr 51 D 81359 München Liefermöglichkeiten und technische Änderungen vorbehalten 1PA31003 A2058 A101 2 7619 ...