background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for EA12

Page 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Page 2: ...SIMADYN D Digital Control System I O module EA12 User Manual Edition 05 95 DK Nr 232241 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are ...

Page 4: ...ification 5 5 Connector pin assignments of X5 6 6 STRUC L menu of the EA12 module in the master program 7 7 Miscellaneous 7 7 1 Appendices 7 7 1 1 Figures 7 7 1 2 Drawings 8 7 1 2 1 Block diagram 8 7 1 2 2 Dimension drawing and table of connectors 8 7 1 2 3 Location diagram 8 8 ECB instructions 9 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 5: ...Warning information Edition 05 95 Siemens AG Dk Nr 232241 SIMADYN D Hardware User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 6: ...the entire obligation of Siemens The warranty contained in the contract between the parties is the sole warranty of Siemens Any statements contained herein do not create new warranties nor modify the existing warranty Warning information W A R N I N G Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and...

Page 7: ...l injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the User Manual which is essential to h...

Page 8: ...ystem startup The outputs can be loaded with up to 10 mA and are proof against short circuit up to a period of 120 sec Caution the total signal load at connector X5 and the associated double test socket must not exceed 10 mA The output format for the individual channels can be configured This is done by specifying a multiplication factor in powers of 2 extra for each channel The 50 pin ribbon cabl...

Page 9: ...tments can be made later in operation ambient temperature accuracy specifications The guide value for temperature sensitivity is 240 uV at a temperature change of 1 deg The following table shows the assignment of potentiometers Rxx to outputs EA12 outputs Connector Offset Gain Output 1 X5 A R49 R46 Output 2 X5 B R55 R52 Output 3 X5 C R61 R58 Output 4 X5 D R67 R64 Output 5 X5 E R73 R70 Output 6 X5 ...

Page 10: ... 0BC0 20 way 2 0 m SC11 6DD 1684 0BB0 Interface modules SE7 1 6DD 1681 0AH1 I O block analog 8 10 channel SE40 6DD 1681 0EA0 Terminal block 20 way one to one 4 Technical specification GENERAL INSULATION GROUP B to VDE 0110 paragraph 13 group 2 at 15V 15 V DC AMBIENT TEMPERATURE 0 to 55 deg C with self ventilation STORAGE TEMPERATURE 40 to 70 deg C PROTECTION CLASS IP00 to DIN 40050 HUMIDITY CLASS ...

Page 11: ...CIRCUIT DURATION 120 sec TOTAL LOAD All outputs simultaneously 10 mA 5 Connector pin assignments of X5 Pin EA12 Connector Relevant test socket 1 Output 1 X5 A X11 SIG 2 Ground X5 A X11 COM 3 Output 2 X5 B X12 SIG 4 Ground X5 B X12 COM 5 Output 3 X5 C X13 SIG 6 Ground X5 C X13 COM 7 Output 4 X5 D X14 SIG 8 Ground X5 D X14 COM 9 Output 5 X5 E X15 SIG 10 Ground X5 E X15 COM 11 Output 6 X5 F X16 SIG 1...

Page 12: ...D A converter 2 X12 X5C 1K D A converter 3 X13 X5D 1K D A converter 4 X14 X5E 1K D A converter 5 X15 X5F 1K D A converter 6 X16 X5G 1K D A converter 7 X17 X5H 1K D A converter 8 X18 See also description of master program 7 Miscellaneous 7 1 Appendices 7 1 1 Figures X 5 X 6 EA12 X 1 20 type of cable SC12 twisted pair Externe Anschlüsse external connections Kabeltyp SC12 paarweise verdrillt Figure 1...

Page 13: ...lock diagram 3GE 465 642 9012 00 SU 7 1 2 2 Dimension drawing and table of connectors Dimension drawing front plate and table of connectors used 3GE 465 642 9012 00 MB 7 1 2 3 Location diagram Location diagram 3GE 465 642 9012 00 A0 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 14: ...s insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive pac...

Page 15: ...ECB instructions 10 Edition 05 95 Siemens AG Dk Nr 232241 SIMADYN D Hardware User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 16: ...n 05 95 11 SIMADYN D Hardware User Manual Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen System Based Technology Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 17: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Reviews: