Page 1: ...Assembly Instructions Product code SR1553 Doc No SR1553 02 260916 UK Email Sales shelters4less co uk Web www shelters4less co uk Tel 0800 160 1002 ...

Page 2: ...1 7 6 13 11 10 12 5 8 9 4 2 3 EXPLODED VIEW AND TOOLS 2 Tools required Drill Screwdriver Mallet Hack saw Tools included Spanner Torx bit ...

Page 3: ... 8 SS Sealing Strip 110x110x40 2 ROLLS 9 PCE1 Roof Panel 110x46 2 10 PCC1 Roof Panel 1030X1135 2 11 RC1 Roof Strip 2060x40x40 5 12 ST3 Roof Tie 2060x40x40 1 13 2MD Roof Edge Trim 106x110x80 5 15 EC40 Plastic End Cap 40x40 12 Fittings Bolt set M10 T25 T50 AB1210 M10 x 60mm Nut Washer Black Cap 25 mm Tech screw 50 mm Tech screw M10 12 x 100 mm Concrete Bolt Pack A B 40 40 80 80 136 66 13 Required 19...

Page 4: ...nels only CB1 JF1 S1 FRAME DETAIL A SCALE 1 7 CB1 UNDERNEATH JF1 ON INNER CB1 CB1 CB1 CB1 Ensure correct alignement on all corners Step 1 Assemble S1 frames to make up the main structure using CB1 brackets for the corners and JF1 brackets for straight joints Also use CB1 and JF1 brackets to secure the ST3 tie bar 4 ...

Page 5: ...RB1 R1 3 1035 1035 1041 1029 FT3 FT1 1 RB1 R1 Step 2 Move the Shelter to its final position and attach all FT1and FT3 foot brackets Then attach R1 roof rafters using RB1 brackets 5 FRONT VIEW 2 ...

Page 6: ... strips SS to the top of the rafters then arange the roof panels by lining up the end panels PCE1 flush with the rafters and leaving a gap between the middle pieces PCC1 Apply more sealing strips to the top of the roof panels directly aboe the strips on the rafters 6 ...

Page 7: ...the shelter using the Tech 50 screws Then apply the 2MD edge trim along the bottom edges of the roof Push fit the Black plastic caps on exposed nuts and bolts Use a mallet to fit the square plastic end caps to any open ends of box sections 7 GENERAL NOTE THE 50 mm TECH SCREWS ARE FOR FIXING ROOF STRIPS RC ONLY ...

Page 8: ...995 1056 50 2171 50 1035 1044 50 1044 50 1035 1035 1035 1135 59 4180 4251 TO FOOT HOLE CENTERS 8 GROUND ANCHOR POSITIONS AND OVERALL SIZE SUGESTED SIZE FOR BASE 200mm OVERSIZES ON ALL 4 SIDES Scale 1 20 ...

Page 9: ...Notes 9 ...

Page 10: ...Notes 10 ...

Page 11: ...Notes 11 ...

Page 12: ...gularly with soapy water Ensure all fitting are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales shelter4less co uk Web www shelters4less co uk Tel 0800 160 1002 Shelters4Less Unit 3 2 Lansdowne Crescent Bournemouth BH1 1SA All Parts and Fixing checked by Print Name Signature ...