background image

R

AIR PURIFIER

OPERATION MANUAL

* The  number  in  this  technology  mark  indicates  an 

approximate number of ions supplied into air of 1 cm

3

which is measured around the center of a room with the 

the high-density plasmacluster ion evolving device is 

placed close to a wall. This product is equipped with a 

device corresponding to this capacity.

Free standing type

“Plasmacluster” and “Device of a cluster 

of grapes” are registered trademarks or 

trademarks of Sharp Corporation.

AUTO

FP-E50E

FP-E50E EN_ML_CS.indb   1

5/26/2557 BE   10:47 AM

Summary of Contents for QNET FP-E50E

Page 1: ...he center of a room with the the high density plasmacluster ion evolving device is placed close to a wall This product is equipped with a device corresponding to this capacity Free standing type Plasmacluster and Device of a cluster of grapes are registered trademarks or trademarks of Sharp Corporation AUTO FP E50E FP E50E EN_ML_CS indb 1 5 26 2557 BE 10 47 AM ...

Page 2: ......

Page 3: ...NTENANCE E 10 FILTER INDICATOR CARE INDEX BACK PANEL and DUST SENSOR HEPA FILTER DEODORIZING FILTER UNIT FILTER REPLACEMENT TROUBLESHOOTING E 14 SPECIFICATIONS E 16 Unique Combination of Air Treatment Technologies Triple Filtration System Plasmacluster TRAPS DUST Pre filter traps dust and other large airborne particles DECREASES ODOURS Deodorizing filter absorbs many common household odours REDUCE...

Page 4: ... Service Centre for any problems adjustments or repairs Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in locations where the unit may get wet such as a bathroom Be cautious when cleaning the unit Strong corrosive cleansers may damage the exterior When carrying the unit hold the unit by handles ...

Page 5: ...erference Avoid a location where the sensor is exposed to direct wind The unit may not operate properly Avoid use in locations where furniture fabrics or other items may come in contact with and restrict the air intake and or air outlet Avoid use in locations where the unit is exposed to condensation or drastic temperature changes Appropriate conditions are when room temperature is between 0 35 ºC...

Page 6: ...ensor Internal 4 Main Unit 1 4 3 1 Air Outlet 2 Handle 2 Locations 3 Dust Sensor Internal 4 HEPA Filter white 5 Deodorizing Filter black 6 Back Panel Pre Filter 7 Air Inlet 8 Power Cord Plug 1 2 3 8 2 4 5 6 Shape of plug depends on country 7 FP E50E EN_ML_CS indb 4 5 26 2557 BE 10 47 AM ...

Page 7: ...Ion OFF Button 5 OFF TIMER Button INDICATOR LIGHT green 6 CHILD LOCK Button Press 3 sec INDICATOR LIGHT green 7 LIGHT CONTROL Button FILTER RESET Button Press 3 sec INDICATOR LIGHT orange 3 2 5 1 6 4 7 Clean Impure Red Yellow Green Clean Impure Red Yellow Green The DUST ODOUR SIGN detects dust odour in the room and indicates the intensity in 3 levels with color changes FP E50E EN_ML_CS indb 5 5 26...

Page 8: ...e wall outlet HEPA filter White Deodorizing filter Black Remove the Back Panel Remove the Filters from the plastic bag Install the Filters in the correct order as shown Install the Back Panel Fill in the usage start date on the Date Label 1 2 3 4 5 Click HEPA filter FP E50E EN_ML_CS indb 6 5 26 2557 BE 10 47 AM ...

Page 9: ...starts in the previous mode it was operated in START START HAZE If the Plasmacluster Ion is OFF the plasmacluster ion will be not released It is possible to switch this mode to another while operating However the HAZE mode will not function after switching mode Releases high density Plasmacluster for 60 minutes then will alternate between Low and High level for 20 minutes each NOTE FP E50E EN_ML_C...

Page 10: ... air The sensors detect impurities for efficient air purification POLLEN DUST SENSOR sensitivity is automatically set to HIGH and quickly detects impurities such as dust and pollen to clean the air AUTO POLLEN LOW MED MAX CHILD LOCK Operation of the unit display will be locked It is the same method as starting operation ON CANCELLATION more 3 sec more 3 sec FP E50E EN_ML_CS indb 8 5 26 2557 BE 10 ...

Page 11: ...ENT OF SENSOR DETECTION SENSITIVITY 1 Set to Low if the DUST ODOUR SIGN is constantly red to reduce sensitivity and set to High if the DUST ODOUR SIGN is constantly green to increase sensitivity 2 3 CAUTION If the power OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity the setting will be saved automatically The sensor sensitivity setting will be saved even if the unit is u...

Page 12: ... INDEX Reminder to perform maintenance of parts below After performing maintenance reset the Filter Indicator Ref E 12 FILTER INDICATOR Be sure to remove the power plug from the wall outlet Notice an unpleasant odour from the air outlet Filter performance appears fall and or odour persist more 3 sec Unit Ref E 12 Back Panel Ref E 11 Deodorizing Filter Ref E 12 HEPA Filter Ref E 12 Dust Sensor Ref ...

Page 13: ...r with kitchen detergent about 10 minutes DO NOT scrub the back panel hard 2 Remove the kitchen detergent with clean water 3 CAUTION Gently remove dust from the sensor opening and the back panel using a vacuum cleaner attachment or similar tool FP E50E EN_ML_CS indb 11 5 26 2557 BE 10 47 AM ...

Page 14: ...G FILTER The maintenance can be applied to the both sides on it so please handle it with care HEPA FILTER DEODORIZING FILTER UNIT CAUTION Wipe with a dry soft cloth Benzine paint thinner polish powder may damage the surface Do not use detergents Detergent ingredients may damage the unit CAUTION Remove the dust on the HEPA FILTER and DEODORIZING FILTER Tag FP E50E EN_ML_CS indb 12 5 26 2557 BE 10 4...

Page 15: ...d is based on the condition of smoking 5 cigarettes per We recommend to replace the lter more frequently if the product is used in a condition signi cantly severer than normal household use FILTER REPLACEMENT NOTE REPLACEMENT FILTER MODEL HEPA Filter 1 unit Deodorizing Filter 1 unit FZ E50HFE FZ E50DFE HEPA Filter Deodorizing Filter Pre Filter Disposal of Filters regulations HEPA Filter material F...

Page 16: ...tton Ref E 10 The DUST ODOUR SIGN are turned off Check to see if the Lights OFF Mode selected If so then press the Lights Control Button to activate the indicator lights Ref E 9 The DUST ODOUR SIGN lights change colour frequently The DUST ODOUR SIGN lights automatically change colours as impurities are detected by the dust sensor and odour sensor Before calling for service please review the Troubl...

Reviews: