background image

FP-J80M

FP-J60M

AIR PURIFIER
OPERATION MANUAL

*  The number in this technology mark indicates an 

approximate number of ions supplied into air of 1 

cm

3

, which is measured around the center of a room 

applicable floor area (at 1.2 m height above the floor) 

when the product is placed close to a wall at the MED 

mode setting.

“Plasmacluster” and “Device of a cluster of grapes” are 
trademarks of Sharp Corporation.

FP-J80M_J60M.indd   1

2018/09/07   10:23:40

Summary of Contents for Plasmacluster FP-J60M

Page 1: ...ns supplied into air of 1 cm3 which is measured around the center of a room applicable floor area at 1 2 m height above the floor when the product is placed close to a wall at the MED mode setting Plasmacluster and Device of a cluster of grapes are trademarks of Sharp Corporation FP J80M_J60M indd 1 2018 09 07 10 23 40 ...

Page 2: ...ently collect dust and other particles Faster airflow at a 20º angle collects dust at lower levels in the room for more effective cleaning Plasmacluster can remove static electricity and can thus prevent dust from attaching to walls and other surfaces Plasmacluster By emitting a balance of positive and negative ions Plasmacluster air treatment is a natural process PM2 5 Monitor Inform by lighting ...

Page 3: ...rmful gases such as carbon monoxide contained in cigarette smoke The air purifier may not completely remove an odor if the source of the odor is still present CONTENTS IMPORTANT SAFETY INSTRUCTIONS 4 PART NAMES 6 PREPARATION 8 OPERATION START STOP 9 AUTO MODE 9 HAZE MODE 9 PLASMACLUSTER ION SPOT MODE 9 SELECTING MODE 9 ON TIMER 10 OFF TIMER 10 SELECTING DISPLAY 10 PLASMACLUSTER ION ON OFF 10 CHILD...

Page 4: ...lly remove dust from the plug Do not insert fingers or foreign objects into the air intake or air outlet When removing the power plug always hold the plug and never pull on the cord Failure to do so can cause a short circuit resulting in electrical shock or fire Be careful not to damage the power cord it may cause electric shock excess heat or fires Do not remove the plug when your hands are wet D...

Page 5: ...direct wind Doing so can cause the main unit to malfunction Avoid locations where furniture fabrics or other objects can come in contact with the main unit and interfere with the intake and outtake of air Avoid locations where the main unit is exposed to condensation or drastic changes in temperature Appropriate room temperature is between 0 35 ºC Place the main unit on a level and stable surface ...

Page 6: ...ocations 7 Front Louver 8 Back Panel Pre Filter 9 Air Inlet 10 Deodorizing Filter 11 HEPA Filter 12 Sensor Internal Sensor Filter Odor Dust sensitive 13 Plasmacluster Ion Generating Unit 14 Unit Holder 15 Unit Cover 16 Unit Cleaning Brush 17 Power Cord Plug 11 13 10 8 9 15 14 12 16 17 1 2 3 4 5 6 7 FP J80M_J60M indd 6 2018 09 07 10 23 42 ...

Page 7: ...ISPLAY OPERATION PANEL Press the button with to start 12 Odor Monitor Indicates the Odor Sensor detects odors TURN OFF Orange Red Clean Impure 13 Unit Replacement Indicator Light 14 Filter Replacement Indicator Light 15 ON Timer Indicator Light 16 OFF Timer Indicator Light 17 Plasmacluster Ion Light 18 DISPLAY PM2 5 Monitor PM2 5 10μg m3 to 499μg m3 is displayed 500μg m3 or more 9μg m3 or less Wat...

Page 8: ...4 Install the Back Panel NOTE When replacing the filter making a memo of the start of use date is recommended FILTER INSTALLATION PREPARATION Always be sure to remove the power plug from the wall outlet HEPA Filter Deodorizing Filter Tag Back Panel HEPA Filter Deodorizing Filter Click FP J80M_J60M indd 8 2018 09 07 10 23 46 ...

Page 9: ...y switch ON and OFF based on room brightness When light control is set to Auto page 11 Use this mode when you want to remove adhering odor germs and other substances from cloths sofas and curtains Adjust Front Louver manually NOTE Emits highdensity Plasmacluster Ions only in the forward direction Discharges stronger air for 8 hours When the operation finishes the main unit will return to its prior...

Page 10: ...nce the selected time is passes Time can be set in from 10 minutes to 24 hours through the designated application Select the length of time you want The Main Unit automatically stops once the selected time is reached Time can be set in from 10 minutes to 24 hours through the designated application ON TIMER OFF TIMER with the Main Unit OFF with the Main Unit ON Front Display Front Display 1hour 2ho...

Page 11: ...right light is ON Room is dark light is OFF Auto Restart If the Main Unit is unplugged or if there is a power failure the Main Unit will resume operation with the previous settings after power is restored Cancellation ON default Adjusting Sensor Sensitivity F3 F5 Light Sensor Low Dust sensitive Sensor Standard default Odor Sensor High When set to Turn off the Darker light illuminates for 8 seconds...

Page 12: ...t with water and dry it thoroughly Plasmacluster Ion Generating Unit electrode section HEPA FILTER DEODORIZING FILTER Wipe with a dry soft cloth Remove the dust gently with a cleaning tool such as a vacuum cleaner MAIN UNIT BACK PANEL CARE AND MAINTENANCE Remove the dust on the filters CAUTION Do not wash the filters Do not expose to sunlight Otherwise these filters may lose efficacy HEPA FILTER M...

Page 13: ...purchasing a replacement filter HEPA Filter 1 unit Deodorizing Filter 1 unit FZ J80HFE FZ J80DFE Disposing of filters Dispose of used filters according to local laws and regulations HEPA Filter material Polypropylene Polyethylene Deodorizing Filter material Polypropylene Polyester Activated carbon HEPA FILTER DEODORIZING FILTER UNIT REPLACEMENT INDICATOR When the total operation time exceeds 17 50...

Page 14: ... connect the power cord to an outlet and then press the Filter Reset Button page 13 The Front Display is turned off When Light control is set to Auto the light automatically turns off when the room is dark Moreover when Light control is set to Turn off the light is always off If you do not want the light to be off set Light control to the Darker setting page 11 The Cleanliness Monitor changes colo...

Page 15: ... floor Standby Power When the main unit s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical circuits To conserve energy unplug the power cord when the main unit is not in use Model FP J80M FP J60M Power supply 220 240 V 50 60 Hz Fan Speed Adjustment MAX MED LOW MAX MED LOW Fan Speed m3 hour 480 288 60 396 222 60 Noise Level dBA 47 45 15 43 40 15 Rated...

Page 16: ...SHARP CORPORATION OSAKA JAPAN Printed in Thailand TINS B175KKRZ 18J FP J80M_J60M indd 16 2018 09 07 10 24 12 ...

Reviews: