Printed in China
TINS-C573WJZZ
06P07-CH-NM
INSTALLATION MANUAL
CAUTION:
•••••
Potential hazard of glass particles if lamp ruptures. In case of lamp rupture, contact your nearest Sharp
Authorized Projector Dealer or Service Center* for replacement.
•••••
Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn
or injury. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to
fully cool before removing the lamp unit.
■
It is recommended that the lamp unit be replaced when the remaining lamp life becomes 5% or less, or when you notice a
significant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized Projector
Dealer or Service Center*. For the name of the nearest Sharp Authorized Projector Dealer or Service Center*,
please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
www.lamprecycle.org or 1-800-BE-SHARP
U.S.A. ONLY
* Confirm the name of the Dealer or Service Center referring to your projector operation manual.
LAMP UNIT (LAMP/CAGE MODULE) FOR PROJECTOR
Model
AN-C430LP
Securing screws
Removing and Installing the
Lamp Unit
Warning!
•
Do not remove the lamp unit from the projector
right after use. The lamp and parts around the lamp
will be very hot and may cause burn or injury.
Info
•
Do not touch the glass surface of the lamp unit or
the inside of the projector.
•
To avoid injury to yourself and damage to the lamp,
make sure you carefully follow the steps below.
•
Do not loosen other screws except for the lamp
unit cover and lamp unit.
1
Press
STANDBY/ON on the projec-
tor or
STANDBY on the remote con-
trol to put the projector into standby
mode.
•
Wait until the cooling fan stops.
2
Disconnect the power cord.
•
Unplug the power cord from the AC socket.
•
Leave the lamp until it has fully cooled down
(about 1 hour).
3
Remove the lamp unit cover.
•
Loosen the user service screw (
1
) that se-
cures the lamp unit cover. Slide down (
2
) and
remove the lamp unit cover (
3
).
4
Remove the lamp unit.
•
Loosen the securing screws from the lamp unit.
Hold the lamp unit and pull it in the direction of
the arrow. At this time, keep the lamp unit hori-
zontal and do not tilt it.
5
Insert the new lamp unit.
•
Press the lamp unit firmly into the lamp unit
compartment. Fasten the securing screws.
6
Replace the lamp unit cover.
•
Align the lamp unit cover and slide it to close.
Then tighten the user service screw to secure
the lamp unit cover.
Info
•
If the lamp unit and lamp unit cover are not cor-
rectly installed, the power will not turn on, even if
the power cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Info
•
Make sure to reset the lamp timer only when re-
placing the lamp. If you reset the lamp timer and
continue to use the same lamp, this may cause
the lamp to become damaged or explode.
1
Connect the power cord.
•
Plug the power cord into the AC socket of the
projector.
2
Reset the lamp timer.
•
While simultaneously holding down
"
,
and
MENU on the projector, press
STANDBY/
ON on the projector.
•
“LAMP 0000H” is displayed, indicating that the
lamp timer is reset.
STANDBY/ON
button
AC socket
1
3
2
User service screw
(for lamp unit cover)
User service screw
(for lamp unit cover)
AC socket
"
button
ENTER button
STANDBY/ON button
MENU button
AN-C430LP_E.p65
06.7.21, 10:41
1