background image

MS Slim Host Adapter Card

 

User’s Manual

 

REV: 1.2

 

Feb. 2021

 

Summary of Contents for PCI4-AD-x8HE-MG4

Page 1: ...1 MS Slim Host Adapter Card User s Manual REV 1 2 Feb 2021...

Page 2: ...signals level CN1 Switchtec UART I F UART with 3 3V TTL signals level J2 ON Force Switchtec entering boot recovery 1 OFF Switchtec loading default FW image as normal opera on default CN9 MicroUSB por...

Page 3: ...8674 to Two x4 link each SFF8654 to one x4 link 3 SRNS Set SFF8674 to Four x2 link each SFF8654 to Two x2 link 4 SRIS Set SFF8674 to one x8 link each SFF8654 to one x4 link 5 SRIS Set SFF8674 to Two x...

Page 4: ...D 1 2 Red Link matching LED for ports in SFF8674 connectors Case 1 set in mode 1 4 or 7 LED1 lights when port in SFF8674 not link at x8 Case 2 set in mode 2 3 5 or 6 LED1 or and LED2 light when ports...

Page 5: ...N2 A17 RX_P3 B17 TX_P3 A18 RX_N3 B18 TX_N3 SFF8674 Pin De ni on SC Mode MS Slim Host Adapter Card CON1 CON2 ROW 1 2 4 5 7 8 CON1 A CLK_0_N CLK_0_P PERP0 PERN0 PERP3 PERN3 B CLK_2_N CLK_2_P PERP1 PERN1...

Page 6: ...and install the CDC driver for unidentified device VID_03EB PID_2018 Available at https www serialcables com wp content uploads 2018 11 SynergyUSBCDC_20180518 rar Figure 2 Figure 1 Figure 3 Figure 4...

Page 7: ...7 MS Slim Host Adapter Card Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14...

Page 8: ...r card and the VT100 Terminal emula on please con gure the VT100 Terminal emula on seHngs to the values shown below Step 3 For Port select COM3 in this example Depend on which COM port used on Host Fo...

Page 9: ...laptop b Put upgrading FW i e us_ms_slim_host_card_v003 srec into the folder of FW c Put update txt in the root folder Step 4 Power cycle host card to apply the new FW FW Upgrading Connect to PC Step...

Page 10: ...10 Commands List MS Slim Host Adapter Card...

Page 11: ...EM Usage fdl fw Note The host card must be reset in every me FW or con gura on le upgrading It will show error message if no reset aLer 1st me and con nue to have 2nd upgrading lsd Command Shows tempe...

Page 12: ...e Usage ssdrst con D all channel C con D con number should be 0 5 channel C channel number should be a or b Channel a The 1st PHY of dual port drive Channel b The 2nd PHY of dual port drive CON1 CON2...

Page 13: ...13 showport Command Shows ports link speed and link width informa on Usage showport MS Slim Host Adapter Card Mode 1 or 4 Mode 3 or 6 Mode 2 or 5 Mode 7...

Page 14: ...Show the clock output status or disable the clock output for all downstream ports Usage clk Usage clk dis en Clock output disable enable feature is dynamically changing without card reset or power cy...

Page 15: ...on should be 1 5 ReadByte D Max read byte is 32 byte WriteData D Max write byte is 32 byte Ex iicwr d4 1 8 0 MS Slim Host Adapter Card iicw Command Byte or page write data to drives from SMbus Usage i...

Page 16: ...mmand Shows card informa on S N uP FW and PCIe switch Switchtec FW version Usage ver reset Command Reset uP FW Usage reset MS Slim Host Adapter Card toggle Command Toggle rmware and con g par ons Usag...

Reviews: