Page 1: ...9007 B0N 0033 0 2006 06 BW 1N Battery Weighing Indicator OWNER S MANUAL ...

Page 2: ... MAINFUNCTIONS 6 SPECCIFICATION 7 PARTNAME KEYFUNCTION 8 SYSTEMMODE 11 GENERALFUNCTION DESCRIPTION 16 CONVERSIONMODE 18 PRINTFORMAT 20 RS 232CCOMMUNICATION 21 USING BATTERY 23 HOWTOINSTALLTHEBW 25 TESTMODE 26 ERRORMESSAGEDESCRIPTION MANAGMENT 30 ...

Page 3: ...n the place with excessive electrical noises and shaking Charge a battery in full to use after negligence for a long time Install the platform on a flat place Never connect AC adaptor while using the dry battery Do not install in the place with voltage and terrible electrical noises Do not use in the place exposed directly to the sun and including much dust ...

Page 4: ...ght setting by sample Low High Weight Comparing Serial Communication Interface RS 232 Serial Printer Connection Self Hardware Test Independent Zero Calibration Gravity Compensation BW 1N BW 6 BW 15 BW 30 BW 60 BW 150 6kg 15kg 30kg 60kg 150kg 2g 5g 10g 20g 50g 280 W 280 D 80 H 405 W 525 D 105 H 280 W 350 D 530 H 425 W 675 D 755 H About 6 kg About 17 kg About 6 hr About 30 hr BL ON About 60 hr BL OF...

Page 5: ... right weight band LOW ON when current weight is less than low limit value BAT Display the battery recharging time rechargeable battery Display the battery replacing time dry battery about 6 9V remain PCS ON when current mode is count mode CHARGE When charging battery charging lamp RED is ON When it is completed charging lamp GREEN is ON POWER ON at connecting the DC 12V adapter Minus ON when weig...

Page 6: ...conds 3 KEY Part Hi Low Comparing Mode key or Weighing Mode Key Counting Mode Key SYSTEM MODE Simple weight mode Display the weight after weighing High Low comparing mode Determine that the weight is high normal or low value and perform the display Count mode Display the quantity by setting the unit or sample weight Quantity comparing mode Perform the display after discrimination by setting High L...

Page 7: ... STEP 3 STEP 4 STEP 5 STEP 6 DESCRIPTION Press twice Press once Low weight input Refer to Digit input In page 11 High value input Refer to Digit input In page 11 Generally operated Empty INPUT INPUT Empty Empty M H H M M M In case of setting the unit weight Min range of unit weight Min Division Step 5 Ex Min division is 0 1 Input the unit weight as 0 532 and round off the second place of decimal t...

Page 8: ... STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 DESCRIPTION Press three times Press once Press once Press once Press five times Simple count input 50pcs Press once ENTER Press once with empty ENTER key Unit weight display Press once Generally operated In case of setting the High Low quantity Display KEY PLATFORM STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 DESCRIPTION Press four times Press once Low valu...

Page 9: ...HOLD FUNCTIOIN Use at weighing the moving object When the weight change is stable after putting the Object 20kg on platform Hold message is displayed The weight is averaged for approx 3 5 sec Press Hold key Auto hold release message is shown for 1 sec And then normally operated Hold lamp is OFF The hold weight is displayed Put the object 10kg on platform Press Hold key Hold message is displayed fo...

Page 10: ...sed F 1 1 9 Automatically power off when the weight is not change or no key is used for 1 9 minutes F 1 Auto power OFF setting Auto power OFF function is used to spare the battery by means of power off when this scale is not used Set point Meaning F 2 0 No transmit F 2 1 F 2 2 Transmit at stable weight F 2 3 Transmit at data request Data request signal D F 2 4 Use for print mode F 2 RS 232C commun...

Page 11: ...count RS 232C communication 1 Port connection method Connect the computer serial port with RS 232C port in the back panel of indicator as follows to communicate with computer 2 RS 232C Output data format Baud rate 9600bps Data bit 8 Stop bit 1 Parity bit None Code ASCII 2 TXD 1 RXD 5 GND 3 Receive Data 2 Transmit Data 7 Signal Ground 4 Request to Send 5 Clear to Send 6 Data Set Ready 8 Carrier Det...

Page 12: ...SCII code corresponding to D is sent to it Warning Open the cover and check the battery type If the battery is not the rechargeable battery this is Mn Alkaline Never connect the AC adaptor jack in the back panel BATTERY 1 Battery replacement or charging time Powerisoffinaspecifictimeafter lampisonintherighttopofdisplaypart Thebatterylampisonwhentheamountofbatteryisabout6 9Vandpowerisoff Whentheamo...

Page 13: ...rging Battery Approx 70 hours Mn Battery Approx 100 hours Alkaline Battery Approx 250 hours Recharging Battery Approx 30 hours Mn Battery Approx 45 hours Alkaline Battery Approx 90 hours HOW TO INSTALL THE BW 1 Open the box with care because indicator is connected to the scale with load cell wire 2 Turn the post knob so as to fix indicator 3 Pull down the wire out of post pipe and insert the post ...

Page 14: ...NTER Key Press once Test running One more time Next menu LCD SCREEN DESCRIPTION Display TEST 2 state Display the digital value Corresponding to current weight TEST 3 FUNCTION Key test KEY ENTER Key Press once Test running One more time Next menu TEST 4 FUNCTION RS 232C communication test Computer link test KEY ENTER Key Press once Test running One more time Next menu Key name code Key name code 1 ...

Page 15: ...Display TEST 7 state for current date time Current date time setting method In the normal mode Press the TARE Key long and can see the message and After this step You can input the current date and time as follows How to set the current date and time KEY TARE Key Shift one digit to the left STAR Key Shift one digit to the right ZERO MODE Key Reset the input value N G Key Increase input value ENTER...

Page 16: ... the TARE weight lower than maximum capacity Or set the maximum capacity higher than the desired TARE weight in calibration menu and perform the calibration again ERROR MESSAGE DESCRIPTION MANAGEMENT Err 13 Zero Range with power on Cause The initial zero range exceeds above 10 of maximum capacity Management Check the load cell state Over Cause Too heavy object is put on platform so that it may exc...