background image

Quick Start Guide

 TXS 3800 

 

 

 

 

 
Form 8219 

Version 1.0 

 June 2021 

Page 1   

About This Quick Start Guide 

This guide is for helping new customers get their Sencore TXS 3800 setup and 
running as quickly and easily as possible. 

The TXS 3800 series of ATSC 3.0 transcoders can receive an ATSC 3.0 signal 
and transcode up to 4x services. 

Download the Full 

User’s Manual 

The current versions of the full u

ser’s manuals can be obtained from the 

Download tab of individual product pages on our website

www.sencore.com

 or 

by emailing Sencore ProCare support a

[email protected]

. 

Unpack the Equipment 

Check that there are no signs of damage to equipment due to transport. If the 
equipment appears to be damaged, please contact Sencore ProCare for support. 

In addition to the Sencore TXS 3800 hardware itself, the box should include 
power cables or AC adapters and various rackmount hardware. 

Equipment Installation and Power Up 

The TXS 3800 server hardware is designed for rack installation and should be 
securely connected to the rack using the included rack rails and screws suitable 
for the rack type. Note that there should be sufficient room for air to freely flow 
around the unit, ensuring proper cooling. The chassis requires front-to-back 
airflow. 

The TXS 3800 server hardware is specified to operate in the range of 100

240VAC, 50-60Hz 

 

 

 

 

 

 

 

Figure 3: TXS 3800 Rear Port Connectors 

1. 

Dual Power Connectors: Provides AC power connection for powering 
the system 

2. 

IPMI Port: Can be used for remote server management, but not 
normally used in the TXS 3800 operation 

3. 

eth0 Port: Network port for management. 

4. 

eth1 Port: Network port for management. 

5. 

VGA Monitor Output 

6. 

ATSC 3.0 RF receiver module 

 

 

Establish a Web Connection to the TXS 3800 

To access the TXS 3800 web user interface, it is necessary to establish an 
Ethernet connection to the device. There are two alternative ways to connect to 
or 

set the device’s management IP address: using the pre-set management IP 

address or connecting a monitor and keyboard to the server. 

Using the Pre-Set Management IP Address 

The Sencore TXS 3800 is shipped with the following factory settings for the 
network ports: 

eth0 Default IP Address:   

10.0.20.101 

eth0 Default Subnet Mask:  

255.255.0.0 

eth1 Default IP Address:   

DHCP 

 
To connect to the web UI, the PC used for setup should have corresponding 
network settings. Connect a PC directly to eth0 using an Ethernet cable. 

 

 

2

 

3

 

4

 

5

 

1

 

6

 

Reviews: